Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Simultaneous amplitude and phase wide-field imaging of AC magnetic signal using diamond quantum magnetometry

皓介 水野, Kosuke Mizuno, 整 石綿, Hitoshi Ishiwata, 雄太 増山, Y. MASUYAMA, 孝之 岩崎, Takayuki Iwasaki, 睦子 波多野, Mutsuko Hatano

Published Dec 1, 2019• 0 citations
OpenAlex

Related papers

Simultaneous wide-field imaging of phase and magnitude of AC magnetic signal using diamond quantum magnetometry

皓介 水野, Kosuke Mizuno, 整 石綿 +7 more

•Jul 1, 2020•0 citations

Phase sensitive quantum magnetometry imaging using emsemble NV center in diamond on wide field optics

皓介 水野, Kosuke Mizuno, 整 石綿 +7 more

•Jun 1, 2019•0 citations

Characteristics of phase sensitive protocol “iQdyne” for diamond quantum magnetometry in wide field optics

皓介 水野, Kosuke Mizuno, 誠人 中島 +9 more

•Mar 1, 2019•0 citations

Simultaneous wide-field imaging of phase and magnitude of AC magnetic signal using diamond quantum magnetometry

Kosuke Mizuno, Hitoshi Ishiwata, Y. MASUYAMA +2 more

Spectroscopic analysis of AC magnetic signal using diamond quantum magnetometry is a promising technique for inductive imaging. Conventional dynamic decoupling like XY8 provides a high sensitivity of an oscillating magnetic signal with intricate dependence on magnitude and phase, complicating high throughput detection of each parameter. In this study, a simple measurement scheme for independent and simultaneous detection of magnitude and phase is demonstrated by a sequential measurement protocol. Wide-field imaging experiment was performed for an oscillating magnetic field with approximately [Formula: see text]-squared observation area. Single pixel phase precision was [Formula: see text] for [Formula: see text] AC magnetic signal. Our method enables potential applications including inductive inspection and impedance imaging.

arXiv:2001.02374•Scientific Reports•Jul 14, 2020•31 citations

Imaging of AC Magnetic Field by Multipulse Quantum Sensing Sequences and Multifrequency Resonance

Shunta Onodera, Yoshiyuki OHKUBO, Yusuke Azuma +3 more

International Conference on Solid State Devices and Materials (SSDM)•Sep 3, 2024•0 citations

Phase sensitive quantum magnetometry imaging using ensemble NV center in diamond on wide field optics

Mizuno, Kosuke, Hitoshi Ishiwata, Y. MASUYAMA +2 more

Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt

•Jun 4, 2019•0 citations
Spectroscopic analysis of AC magnetic signal using diamond quantum magnetometry is a promising technique for inductive imaging. Conventional dynamic decoupling like XY8 provides a high sensitivity of an oscillating magnetic signal with intricate dependence on magnitude and phase, complicating high throughput detection of each parameter. In this study, a simple measurement scheme for independent and simultaneous detection of magnitude and phase is demonstrated by a sequential measurement protocol. Wide-field imaging experiment was performed for an oscillating magnetic field with approximately [Formula: see text]-squared observation area. Single pixel phase precision was [Formula: see text] for [Formula: see text] AC magnetic signal. Our method enables potential applications including inductive inspection and impedance imaging.
Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt