Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

High Generation Yield of Perfectly-Aligned NV centers for Quantum Sensing

孝之 岩崎, Takayuki Iwasaki, 誠人 中島, M. Nakajima, 勇斗 小澤, Hayato Ozawa, 赳行 辻, Takeyuki Tsuji, 睦子 波多野, Mutsuko Hatano, Mutsuko Hatano

Published Feb 1, 2019• 0 citations
OpenAlex

Related papers

Optimizing the density of nitrogen implantation for generating high-density NV center ensembles for quantum sensing

Fupan Feng, Wenlong Zhang, Jian Zhang +3 more

The European Physical Journal D•Sep 1, 2019•7 citations

Selectively-aligned high density NV center ensemble in (111) diamond : from CVD-growth to sensing application

康佐 田原, Kosuke Tahara, 勇斗 小澤 +7 more

•Oct 3, 2016•0 citations

Perfectly aligned shallow ensemble nitrogen-vacancy centers in (111) diamond

Hitoshi Ishiwata, Makoto Nakajima, Kosuke Tahara +3 more

We report the formation of perfectly aligned, high-density, shallow nitrogen vacancy (NV) centers on the (111) surface of a diamond. The study involved step-flow growth with a high flux of nitrogen during chemical vapor deposition (CVD) growth, which resulted in the formation of a highly concentrated (>1019 cm−3) nitrogen layer approximately 10 nm away from the substrate surface. Photon counts obtained from the NV centers indicated the presence of 6.1 × 1015–3.1 × 1016 cm−3 NV centers, which suggested the formation of an ensemble of NV centers. The optically detected magnetic resonance (ODMR) spectrum confirmed perfect alignment (more than 99%) for all the samples fabricated by step-flow growth via CVD. Perfectly aligned shallow ensemble NV centers indicated a high Rabi contrast of approximately 30% which is comparable to the values reported for a single NV center. Nanoscale nuclear magnetic resonance demonstrated surface-sensitive nuclear spin detection and provided a confirmation of the NV centers' depth. Single NV center approximation indicated that the depth of the NV centers was approximately 9–10.7 nm from the surface with error of less than ±0.8 nm. Thus, a route for material control of shallow NV centers has been developed by step-flow growth using a CVD system. Our finding pioneers on the atomic level control of NV center alignment for large area quantum magnetometry.

arXiv:1704.03642•Applied Physics Letters•Jul 24, 2017•60 citations

Quantum sensing using NV centers in diamond

Manuel González Brouwer Raúl

•Mar 29, 2019•0 citations

Quantum sensing using NV centers in diamond

González Brouwer, Raúl

•Jan 1, 2018•0 citations

Vector dc magnetic-field sensing with a reference microwave field using perfectly aligned nitrogen-vacancy centers in diamond

Takuya Isogawa, Yuichiro Matsuzaki, Junko Ishi‐Hayase

The measurement of vector magnetic fields with high sensitivity and spatial resolution is important for both fundamental science and engineering applications. In particular, magnetic-field sensing with nitrogen-vacancy (NV) centers in diamond is a promising approach that can outperform existing methods. Recent studies have demonstrated vector dc magnetic-field sensing with perfectly aligned NV centers, which showed a higher readout contrast than NV centers having four equally distributed orientations. However, to estimate the azimuthal angle of the target magnetic field with respect to the NV axis in these previous approaches, it is necessary to apply a strong reference dc magnetic field, which can perturb the system to be measured. This is a crucial problem, especially when attempting to measure vector magnetic fields from materials that are sensitive to applied dc magnetic fields. Here, we propose a method to measure vector dc magnetic fields using perfectly aligned NV centers without reference dc magnetic fields. This method can be performed even with a single NV center. More specifically, we use the direction of linearly polarized microwave fields to induce Rabi oscillation as a reference and we estimate the azimuthal angle of the target fields from the Rabi frequency. We further demonstrate the potential of our method to improve sensitivity by using entangled states to overcome the standard quantum limit. Our method of using a reference microwave field is an alternative technique for sensitive vector dc magnetic-field sensing.

arXiv:2112.00506•Physical Review A•Jun 29, 2023•10 citations
We report the formation of perfectly aligned, high-density, shallow nitrogen vacancy (NV) centers on the (111) surface of a diamond. The study involved step-flow growth with a high flux of nitrogen during chemical vapor deposition (CVD) growth, which resulted in the formation of a highly concentrated (>1019 cm−3) nitrogen layer approximately 10 nm away from the substrate surface. Photon counts obtained from the NV centers indicated the presence of 6.1 × 1015–3.1 × 1016 cm−3 NV centers, which suggested the formation of an ensemble of NV centers. The optically detected magnetic resonance (ODMR) spectrum confirmed perfect alignment (more than 99%) for all the samples fabricated by step-flow growth via CVD. Perfectly aligned shallow ensemble NV centers indicated a high Rabi contrast of approximately 30% which is comparable to the values reported for a single NV center. Nanoscale nuclear magnetic resonance demonstrated surface-sensitive nuclear spin detection and provided a confirmation of the NV centers' depth. Single NV center approximation indicated that the depth of the NV centers was approximately 9–10.7 nm from the surface with error of less than ±0.8 nm. Thus, a route for material control of shallow NV centers has been developed by step-flow growth using a CVD system. Our finding pioneers on the atomic level control of NV center alignment for large area quantum magnetometry.
The measurement of vector magnetic fields with high sensitivity and spatial resolution is important for both fundamental science and engineering applications. In particular, magnetic-field sensing with nitrogen-vacancy (NV) centers in diamond is a promising approach that can outperform existing methods. Recent studies have demonstrated vector dc magnetic-field sensing with perfectly aligned NV centers, which showed a higher readout contrast than NV centers having four equally distributed orientations. However, to estimate the azimuthal angle of the target magnetic field with respect to the NV axis in these previous approaches, it is necessary to apply a strong reference dc magnetic field, which can perturb the system to be measured. This is a crucial problem, especially when attempting to measure vector magnetic fields from materials that are sensitive to applied dc magnetic fields. Here, we propose a method to measure vector dc magnetic fields using perfectly aligned NV centers without reference dc magnetic fields. This method can be performed even with a single NV center. More specifically, we use the direction of linearly polarized microwave fields to induce Rabi oscillation as a reference and we estimate the azimuthal angle of the target fields from the Rabi frequency. We further demonstrate the potential of our method to improve sensitivity by using entangled states to overcome the standard quantum limit. Our method of using a reference microwave field is an alternative technique for sensitive vector dc magnetic-field sensing.