Nitrogen-vacancy (NV) color centers in diamond are promising solid-state quantum sensors working at room temperature. The number of NV centers limits the magnetic sensitivity of the quantum magnetometer. Increasing the number of NV centers is a challenging task due to technical issues such as microwave power density, detection noise.Here, we developed the sensor system with a large detection volume which contains a lot of NV centers. The microwave circuit enhances microwave power density. Digital filter with frequency modulation of microwave allows us to detect the magnetic field with low noise. Consequently, we obtained a DC magnetic field sensitivity of 980 pT/√Hz.This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.
Nitrogen-vacancy (NV) color centers in diamond are promising solid-state quantum sensors working at room temperature. The number of NV centers limits the magnetic sensitivity of the quantum magnetometer. Increasing the number of NV centers is a challenging task due to technical issues such as microwave power density, detection noise.Here, we developed the sensor system with a large detection volume which contains a lot of NV centers. The microwave circuit enhances microwave power density. Digital filter with frequency modulation of microwave allows us to detect the magnetic field with low noise. Consequently, we obtained a DC magnetic field sensitivity of 980 pT/√Hz.This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.
One of the promising solid-state quantum sensors is nitrogen-vacancy (NV) centers in diamond which can maintain quantum state at room temperature and under atmospheric pressure condition. Further improvement of sensitivity of the sensor is needed to detect the magnetic field from the brain. Noise reduction and simplified system are key techniques especially for the practical use of highly sensitive DC magnetic sensor. In this study, we devised a digital filtering detection method without synchronization between detector and modulator which is a similar noise reduction effect as a lock-in detection technique. We implemented the detection method for the quantum diamond sensor system with the large sensor volume [1]. The Lock-in detection technique is a typical high sensitivity technique for DC magnetic measurement. There are several different implementations of lock-in detection technique for the quantum diamond sensor including microwave modulation, magnetic field modulation, and laser modulation. However, it is a challenging task to obtain high magnetic sensitivity with a compact sensor module because these lock-in detection techniques require a lock-in amplifier or synchronization system. We devised a digital filtering detection method which is an alternative method to the lock-in detection technique. Fluorescence from the NV center is modulated by frequency modulated microwave during optical detected magnetic resonance (ODMR) measurement. The fluorescence is analyzed by digital signal processing which achieves a similar noise reduction effect as a lock-in detection technique. Our method relies on a fact that ODMR converts frequency modulation to amplitude modulation. Thus, our method is applicable not only to the NV center system but also another color center system. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Y. Masuyama et al., Rev. Sci. Instrum. 89, 125007 (2018).
Introduction Nitrogen-vacancy (NV) centers in diamond are promising solid-state quantum sensors. The sensor can potentially monitor the real-time magnetic field at room-temperature toward the brain-machine interface. One of the biggest challenges is to implement a highly sensitive sensor in a compact system. There are two major ways to achieve it. An analog signal processing method with a lock-in amplifier is fast to obtain the signal, but it increases the size of the sensor system. The digital signal processing method with the Fourier transform is simple, but it needs more computational resources. Reducing computational resources with the simple system is an important task for monitoring a real-time magnetic field. In this study, we demonstrate an alternative method of digital signal processing with less computational resources than the Fourier transform. The computational time of the method to compute the signal from n points of data is O(n), whereas the time with Fourier transform is O(n log n). Method and Result We confirm our method with a large detection volume of the ensemble NV centers. The microwave and optical systems used in our experiment are shown in Fig. 1. The diamond sample containing NV centers was placed between the microwave resonator and a compound parabolic concentrator1. We used a coplanar waveguide resonator (CWR) with a wide center electrode for strong and uniform microwave irradiation2. The power of microwave with frequency modulation is 25 dBm before the CWR. The 300 mW laser beam to the diamond was focused with a beam diameter of about 30 μm. The fluorescence from the NV centers was collected through the compound parabolic concentrator and detected using a photodiode. The detected signal of the photodiode is analyzed by digital signal processing. The method obtains the result using a digital filter that effectively becomes a sinc filter using the orthogonality of trigonometric functions by multiplication of the acquired data by a trigonometric function. Figures 2 shows continuous-wave optical detected magnetic resonance (CW-ODMR) spectrum using the digital signal processing with a different modulation frequency of the microwave. The maximum slope and the noise of the signal become smaller with increasing the modulation frequency for different reasons. The low transition rate between quantum states of the NV center reduces the maximum slope for high modulation frequency. While the noise becomes smaller for high modulation frequency. We evaluate the maximum signal slope (Fig. 3) and noise level of the spectrum (Fig. 4). We found the reduction of the noise is greater than the reduction of the maximum slope. This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.
Diamond quantum sensors utilizing nitrogen-vacancy (NV) centers in diamond can measure a tiny magnetic-field variation at room temperature with a high linearity and high spatial resolution. Because of these advantages, they have been actively studied for application to measure a biomagnetic field. In biomagnetic sensing applications, it is effective to measure at multiple points simultaneously with high sensitivity. In this study, we developed a highly sensitive diamond quantum sensor that can simultaneously measure the magnetic field at two points at the millimeter interval. We used two diamonds that were split from one HPHT-grown diamond and placed them at the 3-mm interval. A laser-induced fluorescence from the two diamonds were detected by a single photodiode. We applied different bias magnetic fields to each diamond, and thus the magnetic resonances at these diamonds had different resonance frequencies. By applying microwave fields whose frequencies were modulated at different modulation frequencies, the magnetic fields at the two diamonds can be obtained independently after demodulation. The noise spectral densities in the magnetic field measurement at the two diamonds’ locations. Since the measurement was performed outside a magnetic shield, a severe low-frequency environmental noise from railways and power line (50 Hz) noise peaks were observed. We evaluated the field sensitivities at the two diamonds to be 22 pT/√Hz in 25-300 Hz range with neglecting the power-line noise peaks and the environment noise peaks. The capability of simultaneously measuring a magnetic field at two points with the such high sensitivities will facilitate the biomagnetic sensing applications.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
In this study, we developed a diamond quantum magnetometer based on Ramsey interferometry with a short sensor-to-sample distance. Conventional biomagnetic sensors with ensemble nitrogen-vacancy centers using continuous-wave optically detected magnetic resonance and Ramsey methods typically rely on watt-level lasers to achieve high sensitivity, resulting in thermal issues. In contrast, by employing the light-trapping diamond waveguide technique in a high-pressure and high-temperature diamond sample treated with electron beam irradiation, we obtained a high photon conversion efficiency of 9.5%, enabling us to simultaneously achieve a high sensitivity of 2.93(7) pT/Hz^1/2 in the 100-400 Hz frequency range and a minimal temperature increase of only approximately 13 K at a low laser power of 210 mW. Using a dry phantom designed to mimic magnetoencephalography signals, we measured a weak magnetic field of 77.7(2) pT without signal averaging at a sensor-to-sample distance of 2.5 mm. This short-distance measurement prevents severe spatial signal attenuation, yielding a high signal-to-noise ratio. The development here is crucial for practical biomagnetic applications based on Ramsey interferometry.
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim1pT/\sqrt{\text{Hz}}.Todate,however,demonstrationsofhigh−frequencymagnetometryintheGHzregimewithNVdiamondareordersofmagnitudelesssensitive,abovethenT/\sqrt{\text{Hz}}$ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4 pT/Hz. We demonstrate both amplitude and phase sensing and project tunability over a 300 MHz frequency range. This result increases the viability of NV ensembles to serve as microwave circuitry imagers and near-field probes of antennas.