Physical Review A

Sympathetic-laser-cooling ion microwave frequency standard with accuracy and stability at 10 − 15 level

Y.Z. Zheng, S. N. Miao, Yiting Chen, Wenxin Shi, Jianwei Zhang, Lijun Wang

Published Mar 3, 2026• 0 citations
Publisher
DOI
10.1103/1fp9-738h

Related papers

High-Performance Microwave Frequency Standard Based on Sympathetically Cooled Ions

H. R. Qin, S. N. Miao, J. Z. Han +4 more

The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically cooled ion microwave frequency standard has seldom been studied before. This paper reports a high-performance sympathetically cooled ion microwave frequency standard in a Paul trap. Using laser-cooled ${}^{40}{\mathrm{Ca}}^{+}$ as coolant ions, ${}^{113}{\mathrm{Cd}}^{+}$ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/{\ensuremath{\tau}}^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.

arXiv:2204.05040•Physical Review Applied•Aug 8, 2022•15 citations

A MICROWAVE FREQUENCY STANDARD BASED ON LASER-COOLED 171 Yb + IONS

Richard B. Warrington, Peter Fisk, Michael J. Wouters +1 more

Symposium on Frequency Standards and Metrology•May 1, 2002•12 citations

Laser-cooled ytterbium-ion microwave frequency standard

S. Mulholland, H. A. Klein, G. P. Barwood +6 more

arXiv:1811.06421•Applied Physics B•Oct 5, 2019•25 citations

Sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for Microwave Ion Clocks

J. Z. Han, H. R. Qin, Limin Guo +6 more

We report sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of $^{113}$Cd$^+$ ions was achieved. The temperature of these ions was measured at $90(10)$ mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of $2\times10^{-17}$. Up to $4.2\times10^5$ Cd$^+$ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still $10^5$ Cd$^+$ ions present, indicating that this Ca$^+$--Cd$^+$ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca$^+$ lasers and fluorescence, which was carefully estimated to an accuracy of $5.4(0.5)\times10^{-17}$ using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.

arXiv:2002.04228•Feb 11, 2020•0 citations

Determination of hyperfine splittings and Landé gJ factors of 5s2S1/2 and 5p2P1/2,3/2 states of Cd+111,113 for microwave frequency standards

J. Z. Han, R. Si, H. R. Qin +6 more

Regarding microwave frequency standards based on trapped ions, we report on the determination of the hyperfine splittings and the Land\'e ${g}_{J}$ factors of $^{111,113}\mathrm{Cd}^{+}$. The hyperfine splittings and Land\'e ${g}_{J}$ factors of the $5s{\phantom{\rule{0.16em}{0ex}}}^{2}{S}_{1/2}$ and $5p{\phantom{\rule{0.16em}{0ex}}}^{2}{P}_{1/2,3/2}$ states of $^{111,113}\mathrm{Cd}^{+}$ are calculated using the multiconfiguration Dirac-Hartree-Fock scheme. Furthermore, the hyperfine splittings of the $5p{\phantom{\rule{0.16em}{0ex}}}^{2}{P}_{3/2}$ state of $^{111,113}\mathrm{Cd}^{+}$ are derived based on the laser-induced fluorescence spectroscopy. The ${\mathrm{Cd}}^{+}$ ions are confined in a linear Paul trap and sympathetically cooled by laser-cooled ${\mathrm{Ca}}^{+}$ ions. The calculated values and the derived values are cross-checked, thereby guaranteeing the reliability of our results. The results provided in this paper can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, thus further improving the stability and accuracy of the microwave frequency standards based on trapped $^{111,113}\mathrm{Cd}^{+}$ ions.

arXiv:2201.06719•Physical Review A•Jul 27, 2022•6 citations

Laser-cooled Cs-fountain frequency standard

Kurt Gibble, Steven Chu

Quantum Electronics and Laser Science Conference•May 2, 1993•0 citations
The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically cooled ion microwave frequency standard has seldom been studied before. This paper reports a high-performance sympathetically cooled ion microwave frequency standard in a Paul trap. Using laser-cooled 40Ca+{}^{40}{\mathrm{Ca}}^{+}40Ca+ as coolant ions, 113Cd+{}^{113}{\mathrm{Cd}}^{+}113Cd+ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/{\ensuremath{\tau}}^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.
Sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for Microwave Ion Clocks
We report sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of 113^{113}113Cd+^++ ions was achieved. The temperature of these ions was measured at 90(10)90(10)90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of 2×10−172\times10^{-17}2×10−17. Up to 4.2×1054.2\times10^54.2×105 Cd+^++ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still 10510^5105 Cd+^++ ions present, indicating that this Ca+^++--Cd+^++ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca+^++ lasers and fluorescence, which was carefully estimated to an accuracy of 5.4(0.5)×10−175.4(0.5)\times10^{-17}5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.
Regarding microwave frequency standards based on trapped ions, we report on the determination of the hyperfine splittings and the Land\'e gJ{g}_{J}gJ​ factors of 111,113Cd+^{111,113}\mathrm{Cd}^{+}111,113Cd+. The hyperfine splittings and Land\'e gJ{g}_{J}gJ​ factors of the 5s2S1/25s{\phantom{\rule{0.16em}{0ex}}}^{2}{S}_{1/2}5s2S1/2​ and 5p2P1/2,3/25p{\phantom{\rule{0.16em}{0ex}}}^{2}{P}_{1/2,3/2}5p2P1/2,3/2​ states of 111,113Cd+^{111,113}\mathrm{Cd}^{+}111,113Cd+ are calculated using the multiconfiguration Dirac-Hartree-Fock scheme. Furthermore, the hyperfine splittings of the 5p2P3/25p{\phantom{\rule{0.16em}{0ex}}}^{2}{P}_{3/2}5p2P3/2​ state of 111,113Cd+^{111,113}\mathrm{Cd}^{+}111,113Cd+ are derived based on the laser-induced fluorescence spectroscopy. The Cd+{\mathrm{Cd}}^{+}Cd+ ions are confined in a linear Paul trap and sympathetically cooled by laser-cooled Ca+{\mathrm{Ca}}^{+}Ca+ ions. The calculated values and the derived values are cross-checked, thereby guaranteeing the reliability of our results. The results provided in this paper can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, thus further improving the stability and accuracy of the microwave frequency standards based on trapped 111,113Cd+^{111,113}\mathrm{Cd}^{+}111,113Cd+ ions.