The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically cooled ion microwave frequency standard has seldom been studied before. This paper reports a high-performance sympathetically cooled ion microwave frequency standard in a Paul trap. Using laser-cooled
40Ca+ as coolant ions,
113Cd+ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/{\ensuremath{\tau}}^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.
We report sympathetic cooling of
113Cd
+ by laser-cooled
40Ca
+ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of
113Cd
+ ions was achieved. The temperature of these ions was measured at
90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of
2×10−17. Up to
4.2×105 Cd
+ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still
105 Cd
+ ions present, indicating that this Ca
+--Cd
+ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca
+ lasers and fluorescence, which was carefully estimated to an accuracy of
5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.
Regarding microwave frequency standards based on trapped ions, we report on the determination of the hyperfine splittings and the Land\'e
gJ factors of
111,113Cd+. The hyperfine splittings and Land\'e
gJ factors of the
5s2S1/2 and
5p2P1/2,3/2 states of
111,113Cd+ are calculated using the multiconfiguration Dirac-Hartree-Fock scheme. Furthermore, the hyperfine splittings of the
5p2P3/2 state of
111,113Cd+ are derived based on the laser-induced fluorescence spectroscopy. The
Cd+ ions are confined in a linear Paul trap and sympathetically cooled by laser-cooled
Ca+ ions. The calculated values and the derived values are cross-checked, thereby guaranteeing the reliability of our results. The results provided in this paper can improve the signal-to-noise ratio of the clock transition and the accuracy of the second-order Zeeman shift correction, thus further improving the stability and accuracy of the microwave frequency standards based on trapped
111,113Cd+ ions.