Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Progress towards a Cadmium Ion Microwave Clock: Improvement of the Signal-to-Noise Ratio of the Clock Signal based on Sympathetic Cooling

Yani Zuo, J. Z. Han, Jianwei Zhang, L. J. Wang

Published Apr 1, 2019• 0 citations
Publisher

Abstract

Stable and large sympathetically cooled113Cd+ions were obtained for promising microwave frequency standard. The fluorescence decay during interrogation is one of the main limits to the signal-to-noise ratio (SNR) of clock signal. The decay phenomenon is investigated under different trap condition in both laser cooling (LC) and sympathetic cooling (SC) scenarios. A preliminary evaluation of the system stability and noise limiting is presented.

DOI
10.1109/fcs.2019.8856104

Related papers

Improvement of the signal-to-noise ratio of the clock signal for the frequency standard based on 113Cd+ ions

K. Miao, Jianwei Zhang, Shiguang Wang +2 more

Microwave frequency standard based on laser-cooled113Cd+ions has promising performance. The fluorescence decays during detection are one of main limits to the signal-to-noise ratio (SNR) of clock signal. This phenomena is assumed cause by detection laser. We try to verify this assumption by rate equations. Two mathods to improve SNR are also proposed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•3 citations

Progress Towards a Cadimium Ion Microwave Clock Based on Sympathetic Cooling

Yani Zuo, J. Z. Han, Lei Wei +2 more

The precision of Cadmium ion microwave clock based on linear quadrupole trap is mainly determined by the measurement accuracy of hyperfine splitting of the ground state of113Cd+. To reduce the second order Doppler frequency shift(SODFS), which is one of the main frequency shifts, we take advantages of sympathetic cooling by24Mg+ions to keep the Cadmium ion clouds at relatively low temperature during the interrogation of clock transition. By comparing the experiment results with molecular-dynamics(MD) simulation, we discuss the efficiency of sympathetic cooling and its influence on our clock's performance.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2018•3 citations

Progress on cadmium-ion and ytterbium-ion Microwave Frequency Standards at Tsinghua University

S. N. Miao, Yajing Zheng, Yong Chen +3 more

Abstract As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance 113Cd+ microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of 4.2 × 10 − 13 / τ and a relative frequency uncertainty of 1.8 × 10−14, improving nearly three orders of magnitude compared to the result from JPL. The 0-0 ground-state hyperfine splitting frequency of 113Cd+ was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using 40Ca+ as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to 3.48 × 10 − 13 / τ . Moreover, a microwave frequency standard based on laser-cooled 171Yb+ ions has also been developed in our laboratory since 2021. The short-term frequency instability was measured to be 8.5 × 10 − 13 / τ . The ground-state hyperfine splitting frequency of 171Yb+ was determined to be 12642812118.4674(8) Hz with a fractional frequency uncertainty of 6.33 × 10−14.

Journal of Physics Conference Series•Nov 1, 2024•0 citations

Preliminary results of the microwave frequency standard based on 113Cd+ Ions

Jianwei Zhang, Shiguang Wang, K. Miao +2 more

The transportable microwave frequency standard based on laser-cooled113Cd+ions is a promising to be applied in the comparison of the atomic clocks located in different places. We report the main progress of this clock including the measurements of the clock transition and the preliminary frequency stability.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•0 citations

High-Performance Microwave Frequency Standard Based on Sympathetically Cooled Ions

H. R. Qin, S. N. Miao, J. Z. Han +4 more

The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically cooled ion microwave frequency standard has seldom been studied before. This paper reports a high-performance sympathetically cooled ion microwave frequency standard in a Paul trap. Using laser-cooled ${}^{40}{\mathrm{Ca}}^{+}$ as coolant ions, ${}^{113}{\mathrm{Cd}}^{+}$ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/{\ensuremath{\tau}}^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.

arXiv:2204.05040•Physical Review Applied•Aug 8, 2022•15 citations

Sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for Microwave Ion Clocks

J. Z. Han, H. R. Qin, Limin Guo +6 more

We report sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of $^{113}$Cd$^+$ ions was achieved. The temperature of these ions was measured at $90(10)$ mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of $2\times10^{-17}$. Up to $4.2\times10^5$ Cd$^+$ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still $10^5$ Cd$^+$ ions present, indicating that this Ca$^+$--Cd$^+$ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca$^+$ lasers and fluorescence, which was carefully estimated to an accuracy of $5.4(0.5)\times10^{-17}$ using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.

arXiv:2002.04228•Feb 11, 2020•0 citations
Stable and large sympathetically cooled113Cd+ions were obtained for promising microwave frequency standard. The fluorescence decay during interrogation is one of the main limits to the signal-to-noise ratio (SNR) of clock signal. The decay phenomenon is investigated under different trap condition in both laser cooling (LC) and sympathetic cooling (SC) scenarios. A preliminary evaluation of the system stability and noise limiting is presented.
The precision of Cadmium ion microwave clock based on linear quadrupole trap is mainly determined by the measurement accuracy of hyperfine splitting of the ground state of113Cd+. To reduce the second order Doppler frequency shift(SODFS), which is one of the main frequency shifts, we take advantages of sympathetic cooling by24Mg+ions to keep the Cadmium ion clouds at relatively low temperature during the interrogation of clock transition. By comparing the experiment results with molecular-dynamics(MD) simulation, we discuss the efficiency of sympathetic cooling and its influence on our clock's performance.
Abstract As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance 113Cd+ microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of 4.2 × 10 − 13 / τ and a relative frequency uncertainty of 1.8 × 10−14, improving nearly three orders of magnitude compared to the result from JPL. The 0-0 ground-state hyperfine splitting frequency of 113Cd+ was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using 40Ca+ as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to 3.48 × 10 − 13 / τ . Moreover, a microwave frequency standard based on laser-cooled 171Yb+ ions has also been developed in our laboratory since 2021. The short-term frequency instability was measured to be 8.5 × 10 − 13 / τ . The ground-state hyperfine splitting frequency of 171Yb+ was determined to be 12642812118.4674(8) Hz with a fractional frequency uncertainty of 6.33 × 10−14.
The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically cooled ion microwave frequency standard has seldom been studied before. This paper reports a high-performance sympathetically cooled ion microwave frequency standard in a Paul trap. Using laser-cooled 40Ca+{}^{40}{\mathrm{Ca}}^{+}40Ca+ as coolant ions, 113Cd+{}^{113}{\mathrm{Cd}}^{+}113Cd+ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/{\ensuremath{\tau}}^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.
Sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for Microwave Ion Clocks
We report sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of 113^{113}113Cd+^++ ions was achieved. The temperature of these ions was measured at 90(10)90(10)90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of 2×10−172\times10^{-17}2×10−17. Up to 4.2×1054.2\times10^54.2×105 Cd+^++ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still 10510^5105 Cd+^++ ions present, indicating that this Ca+^++--Cd+^++ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca+^++ lasers and fluorescence, which was carefully estimated to an accuracy of 5.4(0.5)×10−175.4(0.5)\times10^{-17}5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.