Applied Physics Letters

A field-deployable compact gravimeter based on a grating magneto-optical trap with μGal-level long-term stability

Sangwon Seo, Hyun-Gue Hong, J. Lee, Sang Eon Park, Taeg Yong Kwon, Sanglok Lee, Jeongju Choi, Meungho Seo, Jongcheol Park, Sang-Bum Lee

Published Feb 9, 2026• 1 citation
Publisher

Abstract

We present a compact quantum gravimeter based on a grating magneto-optical trap using 87Rb atoms that achieves μGal-level long-term stability without passive vibration isolation. The sensor head integrates magnetic shielding, an ion pump, optical components, and a classical seismometer within a total volume of less than 75L. The gravimeter achieves a sensitivity of 270 μGal/Hz and a stability of 5 μGal at a 1-h average with the long-term gravity record in good agreement with the theoretical tidal model. These results demonstrate a field-deployable platform for portable and chip-integrable quantum gravimetry.

DOI
10.1063/5.0307253

Related papers

A Compact Cold Atom Gravimeter Utilizing a Grating Magneto Optical Trap

Sangwon Seo, Jae Hoon Lee, Sang-Bum Lee +6 more

For a wide range of applications quantum gravimeters demands miniaturizing the physics package of a sensor which is, in laboratory environments, as big as a few meters. One approach to this end is adopting unconventional magneto-optical traps (MOT) such as pyramid MOTs [1] and grating MOTs (gMOT) [2]. In particular, grating MOT has opened an interesting opportunity to integrate complex experimental apparatuses into a planar chip [3], [4].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations

Design and construction of a transportable quantum gravimeter and realization of an atom-chip magnetic trap

Maral Sahelgozin

The quantum gravimeter QG-1 is designed to perform local gravity measurements in field with residual uncertainties surpassing state-of-the-art absolute gravimeters. It will use delta-kick collimated Bose-Einstein condensates (BEC) of 87 Rb atoms as the source for matter-wave interferometry and aims for an uncertainty level below 3 nm/s 2 with a repetition rate of 0.5 Hz. In the frame of this thesis, the atom-chip source has been set up and characterized. In order to meet the requirements for transportability, the apparatus needs to be compact and robust. Additionally, a high BEC flux is desired for the targeted statistical uncertainty. To meet these requirements a double magneto-optical trap (MOT) configuration based on a 3-layer atom chip has been implemented. Furthermore, a compact high power fiber-based laser system has been developed to provide the light for atomic manipulation. To power and control this laser system and generate the magnetic fields necessary to trap atoms, a miniaturized electronic system with low power consumption has been utilized and characterized. The steps towards trapping the atoms inside a magnetic trap on which the evaporation will be implemented have been realized and optimized. A two-dimensional MOT has been employed and an optimized atomic beam flux of 2.2 × 10 9 atoms/s with a mean longitudinal velocity of 17.2 m/s and a narrow longitudinal velocity distribution of 2.2 m/s has been used to load a 3D-chip MOT. The resulting 3D-MOT has been characterized and a loading rate of 8.1×10 8 atoms/s has been attained. After loading for 300 ms, 2.4×10 8 atoms are trapped in the 3D-MOT. Applying a subsequent compressed MOT stage, the cloud density has been increased by a factor of 10. This denser atomic ensemble with 2.9 × 10 10 atoms/cm 3 has been further cooled in a polarization gradient cooling (PGC) stage to 5.6 μK in order to increase the mode match with the subsequent magnetic trap. In the initial large volume magnetic trap generated by the wire structures on the mesoscopic and the base layers of the atom-chip assembly, 3.6 × 10 7 atoms have been captured. This trap features a temperature of 44.3 μK, a trapping frequency of 9.1 Hz in its weak confining axis and a phase-space density of 4.5 × 10 −7 . The process of transferring the atoms into the final magnetic trap with higher trapping frequency for an efficient BEC evaporation, which is formed by the wire structures on the base and science chip has been tested. With this, all the necessary functionalities of a high-flux BEC source setup have been demonstrated.

•Jan 1, 2019•2 citations

Mobile quantum gravimeter with a novel pyramidal magneto-optical trap

Xiaojing Wu, Storm Weiner, Zachary Pagel +2 more

We demonstrate a mobile quantum gravimeter measuring tidal gravity variations in the laboratory and surveying gravity in the field. With simplicity and sensitivity, our instrument paves the way for bringing quantum sensors to field applications.

Conference on Lasers and Electro-Optics•Jan 1, 2020•4 citations

Demonstration of an ultrahigh-sensitivity atom-interferometry absolute gravimeter

Zhong-Kun Hu, Bu-Liang Sun, Xiao‐Chun Duan +5 more

We present an ultrahigh-sensitivity gravimeter based on an ${}^{87}$Rb atom interferometer using stimulated Raman transitions. Compared with our previous work, a two-dimensional magneto-optical trap is added in the new gravimeter to increase the atom number and improve the detection signal-to-noise ratio, and a better optical phase-locked loop system is used to reduce the phase noise of Raman beams. Benefiting from these efforts and the excellent performance of the active vibration isolator, a short-term sensitivity of about 4.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$ ($1\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}\mathrm{Gal}=1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ $\text{m}/{\text{s}}^{2}$) is reached, which improves the sensitivity by a factor of 2 compared with the former best reported value. By a modulation experiment, we further indicate that the residual vibration noise contribution is about 1.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$, which implies a possible improvement over the present absolute gravity measurement level by about one order of magnitude. Moreover, we demonstrate a calibration experiment to directly evaluate the sub-$\ensuremath{\mu}$Gal resolution of our gravimeter.

Physical Review A•Oct 8, 2013•403 citations

Grating chips for quantum technologies

J. P. McGilligan, Paul F. Griffin, Rachel Elvin +3 more

Rb atoms to 3 μK in a micro-fabricated grating magneto-optical trap (GMOT), enabling future mass-deployment in highly accurate compact quantum sensors. We magnetically trap the atoms, and use Larmor spin precession for magnetic sensing in the vicinity of the atomic sample. Finally, we demonstrate an array of magneto-optical traps with a single laser beam, which will be utilised for future cold atom gradiometry.

arXiv:1702.04150•Scientific Reports•Mar 17, 2017•89 citations

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Jongmin Lee, Roger Ding, Justin Christensen +16 more

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. We describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. The vacuum package is integrated into the optomechanical design of a compact cold-atom sensor head with fixed optical components. In addition, a multichannel laser system driven by a single seed laser has been implemented with time-multiplexed frequency shifting using single sideband modulators, reducing the number of optical channels connected to the sensor head. This laser system architecture is compatible with a highly miniaturized photonic integrated circuit approach, and by demonstrating atom-interferometer operation with this laser system, we show feasibility for the integrated photonic approach. In the compact sensor head, sub-Doppler cooling in the GMOT produces 15 μK temperatures, which can operate at a 20 Hz data rate for the atom interferometer sequence. After validating atomic coherence with Ramsey interferometry, we demonstrate a light-pulse atom interferometer in a gravimeter configuration without vibration isolation for 10 Hz measurement cycle rate and T = 0 - 4.5 ms interrogation time, resulting in Δg/g = 2.0e-6. All these efforts demonstrate progress towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

Nature Communications•Sep 1, 2022•101 citations
We present a compact quantum gravimeter based on a grating magneto-optical trap using 87Rb atoms that achieves μGal-level long-term stability without passive vibration isolation. The sensor head integrates magnetic shielding, an ion pump, optical components, and a classical seismometer within a total volume of less than 75L. The gravimeter achieves a sensitivity of 270 μGal/Hz and a stability of 5 μGal at a 1-h average with the long-term gravity record in good agreement with the theoretical tidal model. These results demonstrate a field-deployable platform for portable and chip-integrable quantum gravimetry.
The quantum gravimeter QG-1 is designed to perform local gravity measurements in field with residual uncertainties surpassing state-of-the-art absolute gravimeters. It will use delta-kick collimated Bose-Einstein condensates (BEC) of 87 Rb atoms as the source for matter-wave interferometry and aims for an uncertainty level below 3 nm/s 2 with a repetition rate of 0.5 Hz. In the frame of this thesis, the atom-chip source has been set up and characterized. In order to meet the requirements for transportability, the apparatus needs to be compact and robust. Additionally, a high BEC flux is desired for the targeted statistical uncertainty. To meet these requirements a double magneto-optical trap (MOT) configuration based on a 3-layer atom chip has been implemented. Furthermore, a compact high power fiber-based laser system has been developed to provide the light for atomic manipulation. To power and control this laser system and generate the magnetic fields necessary to trap atoms, a miniaturized electronic system with low power consumption has been utilized and characterized. The steps towards trapping the atoms inside a magnetic trap on which the evaporation will be implemented have been realized and optimized. A two-dimensional MOT has been employed and an optimized atomic beam flux of 2.2 × 10 9 atoms/s with a mean longitudinal velocity of 17.2 m/s and a narrow longitudinal velocity distribution of 2.2 m/s has been used to load a 3D-chip MOT. The resulting 3D-MOT has been characterized and a loading rate of 8.1×10 8 atoms/s has been attained. After loading for 300 ms, 2.4×10 8 atoms are trapped in the 3D-MOT. Applying a subsequent compressed MOT stage, the cloud density has been increased by a factor of 10. This denser atomic ensemble with 2.9 × 10 10 atoms/cm 3 has been further cooled in a polarization gradient cooling (PGC) stage to 5.6 μK in order to increase the mode match with the subsequent magnetic trap. In the initial large volume magnetic trap generated by the wire structures on the mesoscopic and the base layers of the atom-chip assembly, 3.6 × 10 7 atoms have been captured. This trap features a temperature of 44.3 μK, a trapping frequency of 9.1 Hz in its weak confining axis and a phase-space density of 4.5 × 10 −7 . The process of transferring the atoms into the final magnetic trap with higher trapping frequency for an efficient BEC evaporation, which is formed by the wire structures on the base and science chip has been tested. With this, all the necessary functionalities of a high-flux BEC source setup have been demonstrated.
We present an ultrahigh-sensitivity gravimeter based on an 87{}^{87}87Rb atom interferometer using stimulated Raman transitions. Compared with our previous work, a two-dimensional magneto-optical trap is added in the new gravimeter to increase the atom number and improve the detection signal-to-noise ratio, and a better optical phase-locked loop system is used to reduce the phase noise of Raman beams. Benefiting from these efforts and the excellent performance of the active vibration isolator, a short-term sensitivity of about 4.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$ ($1\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}\mathrm{Gal}=1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ m/s2\text{m}/{\text{s}}^{2}m/s2) is reached, which improves the sensitivity by a factor of 2 compared with the former best reported value. By a modulation experiment, we further indicate that the residual vibration noise contribution is about 1.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$, which implies a possible improvement over the present absolute gravity measurement level by about one order of magnitude. Moreover, we demonstrate a calibration experiment to directly evaluate the sub-$\ensuremath{\mu}$Gal resolution of our gravimeter.
Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. We describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. The vacuum package is integrated into the optomechanical design of a compact cold-atom sensor head with fixed optical components. In addition, a multichannel laser system driven by a single seed laser has been implemented with time-multiplexed frequency shifting using single sideband modulators, reducing the number of optical channels connected to the sensor head. This laser system architecture is compatible with a highly miniaturized photonic integrated circuit approach, and by demonstrating atom-interferometer operation with this laser system, we show feasibility for the integrated photonic approach. In the compact sensor head, sub-Doppler cooling in the GMOT produces 15 μK temperatures, which can operate at a 20 Hz data rate for the atom interferometer sequence. After validating atomic coherence with Ramsey interferometry, we demonstrate a light-pulse atom interferometer in a gravimeter configuration without vibration isolation for 10 Hz measurement cycle rate and T = 0 - 4.5 ms interrogation time, resulting in Δg/g = 2.0e-6. All these efforts demonstrate progress towards deployable cold-atom inertial sensors under large amplitude motional dynamics.