A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Jongmin Lee, Roger Ding, Justin Christensen, Randy R. Rosenthal, Aaron M. Ison, Daniel Gillund, David Bossert, Kyle Fuerschbach, William Kindel, Patrick Sean Finnegan, Joel R. Wendt, Michael R. Gehl, Ashok Kodigala, Hayden McGuinness, Charles Alan Walker, Shanalyn A. Kemme, Anthony L. Lentine, Grant W. Biedermann, Peter D. D. Schwindt

Published Sep 1, 2022• 101 citations
Publisher

Abstract

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. We describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. The vacuum package is integrated into the optomechanical design of a compact cold-atom sensor head with fixed optical components. In addition, a multichannel laser system driven by a single seed laser has been implemented with time-multiplexed frequency shifting using single sideband modulators, reducing the number of optical channels connected to the sensor head. This laser system architecture is compatible with a highly miniaturized photonic integrated circuit approach, and by demonstrating atom-interferometer operation with this laser system, we show feasibility for the integrated photonic approach. In the compact sensor head, sub-Doppler cooling in the GMOT produces 15 μK temperatures, which can operate at a 20 Hz data rate for the atom interferometer sequence. After validating atomic coherence with Ramsey interferometry, we demonstrate a light-pulse atom interferometer in a gravimeter configuration without vibration isolation for 10 Hz measurement cycle rate and T = 0 - 4.5 ms interrogation time, resulting in Δg/g = 2.0e-6. All these efforts demonstrate progress towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

DOI
10.1038/s41467-022-31410-4

Related papers

A Compact Cold-Atom Interferometer with a High Data-Rate Grating Magneto-Optical Trap and a Photonic-Integrated-Circuit-Compatible Laser System

Jongmin Lee, Roger Ding, Christensen, Justin +16 more

The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 uK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0 - 4.5 ms interrogation time, resulting in $Δ$ g / g = 2.0e-6. This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

arXiv:2107.04792•Jul 10, 2021•1 citation

Towards miniature cold-atom inertial sensors

Jongmin Lee

We demonstrate a compact light-pulse atom interferometer (LPAI) with a high data-rate grating magneto-optical trap (GMOT) and a photonic-integrated-circuit (PIC)-compatible laser system. These efforts are aligned with one of our primary goals, LPAI operation in high-dynamic environments through ruggedization and miniaturization of the sensor head and laser systems. The compact sensor head is based on a custom vacuum package and a grating chip with fixed optical components. The high data-rate LPAI operation with a GMOT enables the operation of LPAIs in high dynamics. PIC-compatible and PIC-based laser systems are realized and used to demonstrate LPAIs towards miniature cold-atom inertial sensors. Acknowledgement This work was supported by the Laboratory Directed Research and Development program at Sandia National Laboratories and is funded under the DARPA APhI program. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. This paper describes technical results and analysis. Any subjective views or opinions that might be expressed in the paper do not necessarily represent the view of the U.S. Department of Energy or the United States Government.

Optical and Quantum Sensing and Precision Metrology II•Mar 9, 2022•0 citations

INTEGRATED PHOTONICS AND VACUUM PACKAGE DEVELOPMENT FOR A COLD-ATOM INTERFEROMETER .

Peter D. D. Schwindt

We report the current progress in the development of a compact, deployable cold-atom interferometry sensor platform towards atomic sensors for position, navigation, and time (PNT) applications.A simplified atomic sensor head with diffractive optics, a fixed-alignment optical package, and photonic-integrated-circuit (PIC) compatible laser architecture [1] are essential for its compactness and deployability.This cold atom sensor platform can be generally applied to gravimeters, accelerometers, gyroscopes, and clocks, and the sensor platform includes significant engineering efforts in the development of grating-mirror magneto-optical traps (G-MOTs), ridgid structural design, a custom titanium vacuum package with passive pumping, and silicon photonics multi-channel on-chip single sideband modulators.

•Dec 1, 2021•0 citations

A Compact, High-Data-Rate, High-Sensitivity GMOT-Based Light-Pulse Atom Interferometer toward Time-Multiplexed, Multi-Axis Inertial Sensing

Benjamin Smith, Adrian Orozco, Jongmin Lee

Light-pulse atom interferometry has emerged as a promising approach for developing quantum inertial and gravity sensors for real-world applications, but achieving robust operation in dynamic environments without sacrificing sensitivity remains challenging. To mitigate performance degradations resulting from vibration-induced noise and mismatches in the spatial overlap between free-falling atoms and light pulses, we demonstrate a first-of-a-kind high-data-rate, high-sensitivity grating magneto-optical trap (GMOT)-based light-pulse atom interferometer (LPAI). This system uses a compact, rugged GMOT architecture, based on an in-vacuum microfabricated grating chip and a single laser-cooling beam, to enable high-data-rate GMOT-based cold-atom generation with sub-Doppler cooling. Our GMOT-based LPAI operates at high data rates (up to 100 Hz), while simultaneously achieving both high acceleration sensitivity (550 ng/rt-Hz at 20 Hz, 1.49 ug/rt-Hz at 45 Hz, and 6.31 ug/rt-Hz at 70 Hz) and good bias stability (71 ng). This compact, rugged architecture paves the way for field-deployable quantum inertial and gravity sensors in high dynamics and for time-multiplexed, multi-axis inertial sensing.

arXiv:2610.01735•Oct 1, 2026•0 citations

A cold atom interferometry sensor platform based on diffractive optics and integrated photonics

Peter D. D. Schwindt, Jongmin Lee, Hayden McGuinness +15 more

We report the current progress in the development of a compact, deployable cold-atom interferometry sensor platform towards atomic sensors for position, navigation, and time (PNT) applications. A simplified atomic sensor head with diffractive optics, an alignment-free optical package, and photonic-integrated-circuit (PIC) compatible laser architecture [1] are essential for its compactness and deployability. This cold-atom sensor platform can be generally applied to gravimeters, accelerometers, gyroscopes, and clocks, and the sensor platform includes significant engineering efforts in the development of grating-mirror magneto-optical traps (G-MOTs), custom titanium vacuum package with passive pumping, and silicon photonics multi-channel on-chip single sideband modulators.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Progress on a Miniature Cold-Atom Frequency Standard

David R. Scherer, Robert Lutwak, Mark J. Mescher +8 more

Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.

arXiv:1411.5006•Nov 18, 2014•7 citations
Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. We describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. The vacuum package is integrated into the optomechanical design of a compact cold-atom sensor head with fixed optical components. In addition, a multichannel laser system driven by a single seed laser has been implemented with time-multiplexed frequency shifting using single sideband modulators, reducing the number of optical channels connected to the sensor head. This laser system architecture is compatible with a highly miniaturized photonic integrated circuit approach, and by demonstrating atom-interferometer operation with this laser system, we show feasibility for the integrated photonic approach. In the compact sensor head, sub-Doppler cooling in the GMOT produces 15 μK temperatures, which can operate at a 20 Hz data rate for the atom interferometer sequence. After validating atomic coherence with Ramsey interferometry, we demonstrate a light-pulse atom interferometer in a gravimeter configuration without vibration isolation for 10 Hz measurement cycle rate and T = 0 - 4.5 ms interrogation time, resulting in Δg/g = 2.0e-6. All these efforts demonstrate progress towards deployable cold-atom inertial sensors under large amplitude motional dynamics.
The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 uK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0 - 4.5 ms interrogation time, resulting in ΔΔΔ g / g = 2.0e-6. This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.
We demonstrate a compact light-pulse atom interferometer (LPAI) with a high data-rate grating magneto-optical trap (GMOT) and a photonic-integrated-circuit (PIC)-compatible laser system. These efforts are aligned with one of our primary goals, LPAI operation in high-dynamic environments through ruggedization and miniaturization of the sensor head and laser systems. The compact sensor head is based on a custom vacuum package and a grating chip with fixed optical components. The high data-rate LPAI operation with a GMOT enables the operation of LPAIs in high dynamics. PIC-compatible and PIC-based laser systems are realized and used to demonstrate LPAIs towards miniature cold-atom inertial sensors. Acknowledgement This work was supported by the Laboratory Directed Research and Development program at Sandia National Laboratories and is funded under the DARPA APhI program. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. This paper describes technical results and analysis. Any subjective views or opinions that might be expressed in the paper do not necessarily represent the view of the U.S. Department of Energy or the United States Government.
We report the current progress in the development of a compact, deployable cold-atom interferometry sensor platform towards atomic sensors for position, navigation, and time (PNT) applications.A simplified atomic sensor head with diffractive optics, a fixed-alignment optical package, and photonic-integrated-circuit (PIC) compatible laser architecture [1] are essential for its compactness and deployability.This cold atom sensor platform can be generally applied to gravimeters, accelerometers, gyroscopes, and clocks, and the sensor platform includes significant engineering efforts in the development of grating-mirror magneto-optical traps (G-MOTs), ridgid structural design, a custom titanium vacuum package with passive pumping, and silicon photonics multi-channel on-chip single sideband modulators.
Light-pulse atom interferometry has emerged as a promising approach for developing quantum inertial and gravity sensors for real-world applications, but achieving robust operation in dynamic environments without sacrificing sensitivity remains challenging. To mitigate performance degradations resulting from vibration-induced noise and mismatches in the spatial overlap between free-falling atoms and light pulses, we demonstrate a first-of-a-kind high-data-rate, high-sensitivity grating magneto-optical trap (GMOT)-based light-pulse atom interferometer (LPAI). This system uses a compact, rugged GMOT architecture, based on an in-vacuum microfabricated grating chip and a single laser-cooling beam, to enable high-data-rate GMOT-based cold-atom generation with sub-Doppler cooling. Our GMOT-based LPAI operates at high data rates (up to 100 Hz), while simultaneously achieving both high acceleration sensitivity (550 ng/rt-Hz at 20 Hz, 1.49 ug/rt-Hz at 45 Hz, and 6.31 ug/rt-Hz at 70 Hz) and good bias stability (71 ng). This compact, rugged architecture paves the way for field-deployable quantum inertial and gravity sensors in high dynamics and for time-multiplexed, multi-axis inertial sensing.
We report the current progress in the development of a compact, deployable cold-atom interferometry sensor platform towards atomic sensors for position, navigation, and time (PNT) applications. A simplified atomic sensor head with diffractive optics, an alignment-free optical package, and photonic-integrated-circuit (PIC) compatible laser architecture [1] are essential for its compactness and deployability. This cold-atom sensor platform can be generally applied to gravimeters, accelerometers, gyroscopes, and clocks, and the sensor platform includes significant engineering efforts in the development of grating-mirror magneto-optical traps (G-MOTs), custom titanium vacuum package with passive pumping, and silicon photonics multi-channel on-chip single sideband modulators.
Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.