Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optimal quantum control and optical beam shaping for atomic gravi-gradiometer

Joel Gomes Baptista, Louis Pagot, Léo Rol, Niranjan Myneni, Leonid A. Sidorenkov, Sébastien Merlet, Franck Pereira dos Santos

Published Sep 8, 2025• 0 citations
OpenAlex

Related papers

Ultra high sensitivity quantum gravi-gradiometer

Joel Gomes Baptista, Valentin Cambier, Leonid A. Sidorenkov +2 more

•Jun 12, 2023•0 citations

Quantum enhanced ultra high sensitivity gravi-gradiometer

Valentin Cambier, Joel Gomes Baptista, Leonid A. Sidorenkov +2 more

•Jun 18, 2023•0 citations

Quantum Optimal Control for Sensitive Atomic Gravimetry

Leonid A. Sidorenkov, Joel Gomes Baptista, Valentin Cambier +2 more

•Jun 25, 2024•0 citations

Quantum optimal control for sensitive atomic gravimetry

Louis Pagot, Joel Gomes Baptista, Léo Rol +5 more

•Jul 21, 2025•0 citations

Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure

Zinan Wu, Jialong Zhang, Wei Chen +4 more

We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz 1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.

Optics Letters•Apr 18, 2024•8 citations

Quantum Optimal Control for Atomic Interferometer

Louis Pagot, Joel Gomes Baptista, Léo Rol +4 more

•Jun 30, 2025•0 citations
We report a single-beam synthetic gradiometer operated in the spin-exchange-relaxation free (SERF) regime, using the structure of two separate atomic vapor cells spaced 2 cm apart. To improve the capability of the gradiometer in suppressing the common-mode magnetic field noise, we are aiming at investigating the effects of the system parameters on the gradiometer common-mode rejection ratio (CMRR). The mathematical expression for the relationship between the gradiometer CMRR and the two variables including the linewidth ratio and the pumping factor ratio is constructed for the first time, to our knowledge. This means that the CMRR can be optimized by controlling the linewidth and the pumping factor, which is easy to implement in the operation process. As a result, a CMRR of 246 is achieved and a gradiometer sensitivity of 4.5 fT/cm/Hz 1/2 is also measured. This method provides a theoretical and experimental basis for the automated operation of gradiometers, and the gradiometer system performance can be tuned to a desired state by simply controlling the linewidth and the incident light intensity.