Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Metrology for Bits and Qubits in Meters: Operational Standards, State-Space Geometry, and Traceable Calibration Chains

Douglas C Youvan

Published Jan 1, 2026• 0 citations
Publisher
DOI
10.13140/rg.2.2.32445.52966

Related papers

Quantum calibrations traceable through classical radiometry

Michelle S. Stephens, M. G. White, Thomas Gerrits +2 more

A system for calibrating single photon detector efficiency that is traceable to the SI through a state-of-the-art classical optical fibre radiometer has been developed and is in the process of being vetted as a calibration service at the National Institute of Standards and Technology (NIST). The method of calibration is direct substitution to power meters relative to NIST's optical fibre cryogenic primary standard and builds on the existing measurement infrastructure for the calibration of optical fibre power meters. Recent improvements to the optical fibre cryogenic radiometer make it more robust and deployable. The traceability of the single photon detector calibration service under development to these classical measurements is discussed, along with a description of the technique used in this calibration service to calibrate the detection efficiency of single photon detectors. Finally, we discuss work on the development of these technologies so that in the future they may be deployable to the point-of- use.

Measurement Sensors•Sep 22, 2021•3 citations

Introduction to Quantum Metrology

Waldemar Nawrocki

Springer eBooks•Jan 1, 2015•12 citations

Pilot comparison on the measurement of detection efficiency of InGaAs/InP single-photon detectors (Conference Presentation)

Marco López

InGaAs/InP single-photon detectors are today the most frequently used detectors for fibre-based Quantum Key Distribution (QKD) [1,2]. The performance of the QKD-systems greatly depends on the optical properties of its detector, such as quantum efficiency, dead time, dark counts, gating rate, etc., which need to be metrologically characterized to fully grantee the QKD network security. Therefore, several European National Metrological Institutes (NMIs) are putting today great efforts in developing novel measurement methods and calibration facilities, which allow to perform the traceable characterisation of single-photon detectors by using reference standards [3, 4]. From the metrological, and specifically radiometric, point of view, the detection efficiency of the single-photon detector is the main parameter that needs to be traceable to the primary standard for optical power (i.e. the cryogenic radiometer), which is maintained by most of the NMIs. Recently, four European NMIs have carried out a pilot comparison on the detection efficiency of a free-running InGaAs/InP single-photon detector, which main purpose has been to provide a snapshot of the measurement capabilities of the four European NMIs in the field of photon counting detection. The comparison was carried out in the framework of the EMPIR project 14IND05 “Optical metrology for quantum-enhanced secure telecommunication (MIQC2)” at the telecom wavelength of 1550 nm by using different reference standards with independently traceability chains. The results of this comparison, including the different experimental setups, the measurement methods, the traceability chain and the uncertainty evaluation of each participant, will be presented in this conference. References: [1] Akihisa Tomita, et al., “High speed quantum key distribution system”, Optical Fiber Technology, 16, Issue 1, 55-62 (2010). [2] Damien Stucki, et al., “Photon counting for quantum key distribution with peltier cooled InGaAs/InP APDs”, Journal of Modern Optics, 48, Issue 13, 1967-1981 (2001). [3] M. López, et al, “Detection efficiency calibration of single-photon silicon avalanche photodiodes traceable using double attenuator technique, Journal of Modern Optics 62, S21 – S27, 2015. [4] G. Porrovecchio, et al., “Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique”, Metrologia 53, 1115-1122 (2016).

SPIE Quantum Technologies•May 29, 2018•0 citations

Introduction to Quantum Metrology

Waldemar Nawrocki

Springer eBooks•Jan 1, 2019•16 citations

Quantum Metrology: Foundation of Units and Measurements

Ernst Otto Göbel, U. Siegner

Wiley eBooks•Jun 12, 2015•35 citations

Metrology Perspective of Single‐Photon Detectors: Review on Global Calibration Methods

Anish Mahavir Bhargav, Rajib Kumar Rakshit, Samaresh Das +1 more

Abstract The evolution of quantum standards for SI units and funding support from national governments has led to rapid technological developments in the quantum sciences. With this, new and more powerful quantum optical devices that find applications in several fields are obtained. Single‐photon detectors (SPDs) are considered as a critical element in these emerging technologies. A traceability chain for SPD calibration is required to ensure their performance reliability and quality. Different methods and techniques are being developed worldwide for the calibration of SPDs. In this paper, the developments that have occurred globally in SPD calibration and the uncertainty value achieved until now are summarized along with the scope of possible improvement areas.

Advanced Quantum Technologies•Aug 12, 2021•14 citations
A system for calibrating single photon detector efficiency that is traceable to the SI through a state-of-the-art classical optical fibre radiometer has been developed and is in the process of being vetted as a calibration service at the National Institute of Standards and Technology (NIST). The method of calibration is direct substitution to power meters relative to NIST's optical fibre cryogenic primary standard and builds on the existing measurement infrastructure for the calibration of optical fibre power meters. Recent improvements to the optical fibre cryogenic radiometer make it more robust and deployable. The traceability of the single photon detector calibration service under development to these classical measurements is discussed, along with a description of the technique used in this calibration service to calibrate the detection efficiency of single photon detectors. Finally, we discuss work on the development of these technologies so that in the future they may be deployable to the point-of- use.
InGaAs/InP single-photon detectors are today the most frequently used detectors for fibre-based Quantum Key Distribution (QKD) [1,2]. The performance of the QKD-systems greatly depends on the optical properties of its detector, such as quantum efficiency, dead time, dark counts, gating rate, etc., which need to be metrologically characterized to fully grantee the QKD network security. Therefore, several European National Metrological Institutes (NMIs) are putting today great efforts in developing novel measurement methods and calibration facilities, which allow to perform the traceable characterisation of single-photon detectors by using reference standards [3, 4]. From the metrological, and specifically radiometric, point of view, the detection efficiency of the single-photon detector is the main parameter that needs to be traceable to the primary standard for optical power (i.e. the cryogenic radiometer), which is maintained by most of the NMIs. Recently, four European NMIs have carried out a pilot comparison on the detection efficiency of a free-running InGaAs/InP single-photon detector, which main purpose has been to provide a snapshot of the measurement capabilities of the four European NMIs in the field of photon counting detection. The comparison was carried out in the framework of the EMPIR project 14IND05 “Optical metrology for quantum-enhanced secure telecommunication (MIQC2)” at the telecom wavelength of 1550 nm by using different reference standards with independently traceability chains. The results of this comparison, including the different experimental setups, the measurement methods, the traceability chain and the uncertainty evaluation of each participant, will be presented in this conference. References: [1] Akihisa Tomita, et al., “High speed quantum key distribution system”, Optical Fiber Technology, 16, Issue 1, 55-62 (2010). [2] Damien Stucki, et al., “Photon counting for quantum key distribution with peltier cooled InGaAs/InP APDs”, Journal of Modern Optics, 48, Issue 13, 1967-1981 (2001). [3] M. López, et al, “Detection efficiency calibration of single-photon silicon avalanche photodiodes traceable using double attenuator technique, Journal of Modern Optics 62, S21 – S27, 2015. [4] G. Porrovecchio, et al., “Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique”, Metrologia 53, 1115-1122 (2016).
Abstract The evolution of quantum standards for SI units and funding support from national governments has led to rapid technological developments in the quantum sciences. With this, new and more powerful quantum optical devices that find applications in several fields are obtained. Single‐photon detectors (SPDs) are considered as a critical element in these emerging technologies. A traceability chain for SPD calibration is required to ensure their performance reliability and quality. Different methods and techniques are being developed worldwide for the calibration of SPDs. In this paper, the developments that have occurred globally in SPD calibration and the uncertainty value achieved until now are summarized along with the scope of possible improvement areas.