Metrology for Bits and Qubits in Meters: Operational Standards, State-Space Geometry, and Traceable Calibration Chains

Douglas C Youvan

Published Jan 1, 2026• 0 citations
Publisher
DOI
10.13140/rg.2.2.32445.52966

Related papers

Introduction to Quantum Metrology: Quantum Standards and Instrumentation

Waldemar Nawrocki

Springer eBooks•Jan 1, 2015•27 citations

Quantum calibrations traceable through classical radiometry

Michelle S. Stephens, M. G. White, Thomas Gerrits +2 more

A system for calibrating single photon detector efficiency that is traceable to the SI through a state-of-the-art classical optical fibre radiometer has been developed and is in the process of being vetted as a calibration service at the National Institute of Standards and Technology (NIST). The method of calibration is direct substitution to power meters relative to NIST's optical fibre cryogenic primary standard and builds on the existing measurement infrastructure for the calibration of optical fibre power meters. Recent improvements to the optical fibre cryogenic radiometer make it more robust and deployable. The traceability of the single photon detector calibration service under development to these classical measurements is discussed, along with a description of the technique used in this calibration service to calibrate the detection efficiency of single photon detectors. Finally, we discuss work on the development of these technologies so that in the future they may be deployable to the point-of- use.

Measurement Sensors•Sep 22, 2021•4 citations

Pilot comparison on the measurement of detection efficiency of InGaAs/InP single-photon detectors (Conference Presentation)

Marco López

InGaAs/InP single-photon detectors are today the most frequently used detectors for fibre-based Quantum Key Distribution (QKD) [1,2]. The performance of the QKD-systems greatly depends on the optical properties of its detector, such as quantum efficiency, dead time, dark counts, gating rate, etc., which need to be metrologically characterized to fully grantee the QKD network security. Therefore, several European National Metrological Institutes (NMIs) are putting today great efforts in developing novel measurement methods and calibration facilities, which allow to perform the traceable characterisation of single-photon detectors by using reference standards [3, 4]. From the metrological, and specifically radiometric, point of view, the detection efficiency of the single-photon detector is the main parameter that needs to be traceable to the primary standard for optical power (i.e. the cryogenic radiometer), which is maintained by most of the NMIs. Recently, four European NMIs have carried out a pilot comparison on the detection efficiency of a free-running InGaAs/InP single-photon detector, which main purpose has been to provide a snapshot of the measurement capabilities of the four European NMIs in the field of photon counting detection. The comparison was carried out in the framework of the EMPIR project 14IND05 “Optical metrology for quantum-enhanced secure telecommunication (MIQC2)” at the telecom wavelength of 1550 nm by using different reference standards with independently traceability chains. The results of this comparison, including the different experimental setups, the measurement methods, the traceability chain and the uncertainty evaluation of each participant, will be presented in this conference. References: [1] Akihisa Tomita, et al., “High speed quantum key distribution system”, Optical Fiber Technology, 16, Issue 1, 55-62 (2010). [2] Damien Stucki, et al., “Photon counting for quantum key distribution with peltier cooled InGaAs/InP APDs”, Journal of Modern Optics, 48, Issue 13, 1967-1981 (2001). [3] M. López, et al, “Detection efficiency calibration of single-photon silicon avalanche photodiodes traceable using double attenuator technique, Journal of Modern Optics 62, S21 – S27, 2015. [4] G. Porrovecchio, et al., “Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique”, Metrologia 53, 1115-1122 (2016).

SPIE Quantum Technologies•May 29, 2018•0 citations

Qubits, Operators and Measurement

Jack D. Hidary

Springer eBooks•Sep 30, 2021•0 citations

Qubits, Operators and Measurement

Jack D. Hidary

Springer eBooks•Jan 1, 2019•1 citation

相关光子自校准微光辐亮度计的光学设计

史佳庆 SHI Jiaqing, 俞兵 Yu Bing, 储隽伟 Chu Junwei +3 more

The high-precision self-calibration radiation reference source is currently the research focus of satellite remote sensing calibration. In order to meet the requirements of quantitative applications such as climate monitoring, low-light radiation metering and single photon source radiance measurement, in view of the application requirements and technical requirements of visible to near infrared low-light radiometer, a compact three-channel low-light radiance meter based on correlated photon self-calibration is designed. This design method can improve the measurement accuracy of low light irradiance by using objective physical effect instead of physical standard, reducing the cumulative error caused by standard transfer chain. The absolute calibration of the detector responsivity can be achieved by the spontaneous parameter down-conversion effect, and the absolute radiation observation can be achieved without relying on the external reference. Based on this study, combined with the special application requirements of radiance meter, a numerical model of spectral rate and geometric transmission characteristics of wide spectrum correlated photons is established, and two basic operating modes of self-calibration and radiation observation are determined. The interaction between 355 nm pump source and nonlinear medium generates three-wave mixing, and the correlated photons are generated by class I non-collinear spontaneous parametric downconversion, the combined effect of monochromatic pump photon flow and quantum vacuum noise on non-centrosymmetric nonlinear crystal makes each incident photon spontaneously split into two photons with lower energy with a certain probability, called signal photons and idle photons respectively, they have a wide sptrum distribution from pump wave frequency to lattice resonance frequency. Correlated photon source has the technical characteristics of time and space correlation, natural wide spectrum and absolute reproducibility, so it has high absolute accuracy. Integrated design of self-calibration and radiation observation can monitor and correct changes in response characteristics in real time, maintain long-term stability of response characteristics, and improve traceability and accuracy of observation data. This design method solve the key technologies such as preparation and value transfer of correlated photon sources, suppression of pump stray light, high precision and high efficiency coupling of correlated photons, UV radiation resistance of space single-photon detectors, packaging reinforcement technology of space single-photon detectors,self-calibration and integrated design of radiation observation. The spectral measurement range of the low-light radiance meter is from 460 nm to 1 550 nm, the measurement range of radiance is 1×10-9~1×10-6 W/(cm2·sr·nm). In the design, the integration, miniaturization and modularization of the whole system are considered, and the eight spectral bands are integrated into a three-channel structure, solving the preparation of wide spectrum dependent photon source, optical multiplexing of calibration optical path, radiation measurement, high precision coincidence measurement and full optical path calibration of radiance meter, and achieving high precision radiation observation from visible to near infrared and periodic self-calibration research targets. In the self-calibration mode, the multiplex optical path module periodically introduces the spontaneous parametric down-conversion correlated photons, and the photon counting and coincidence detection module are used to calibrate the absolute quantum efficiency of the three channels. In the radiation observation mode, the multiplex optical path module introduces the low-light level target radiation and obtains the absolute spectral radiance of the observation target in the band of 460~1 550 nm at the same time. The calibration coefficient obtained by the self-calibration mode is used to correct the observation results. The effects of link error limited by radiation reference value transfer, optical decay of optical path and electronic decay of optical path on the measurement accuracy of microradiance are fundamentally solved. The visible near-infrared band adopts free space coupling mode and the short-wave infrared band adopts multi-mode fiber coupling mode. Through design optimization analysis, the focusing spots of the first and second channels meet the 300 μm pixel requirement of Si single photon detector, and the focusing spot of the third channel meets the 62.5 μm core diameter and 0.22 numerical aperture requirement of multi-mode fiber, all of them can be received by the detector photosensitive surface, meeting the design objectives. The method based on correlated photon calibration does not need to trace the high-precision primary standard in the laboratory and the lengthy standard transfer chain. By using the correlated photon generated in the process of parametric down-conversion, the calibration source of time, space and polarization can be obtained, and the high-precision observation of the low-light spectrum radiance from visible to near infrared band can be realized. The solution to the scientific problem of low-light observation instrument in space platform measurement can obtain higher calibration accuracy, and play an important role in climate monitoring, low-light radiation metrology, single-photon source radiance measurement and so on.

ACTA PHOTONICA SINICA•Jan 1, 2023•1 citation
A system for calibrating single photon detector efficiency that is traceable to the SI through a state-of-the-art classical optical fibre radiometer has been developed and is in the process of being vetted as a calibration service at the National Institute of Standards and Technology (NIST). The method of calibration is direct substitution to power meters relative to NIST's optical fibre cryogenic primary standard and builds on the existing measurement infrastructure for the calibration of optical fibre power meters. Recent improvements to the optical fibre cryogenic radiometer make it more robust and deployable. The traceability of the single photon detector calibration service under development to these classical measurements is discussed, along with a description of the technique used in this calibration service to calibrate the detection efficiency of single photon detectors. Finally, we discuss work on the development of these technologies so that in the future they may be deployable to the point-of- use.
InGaAs/InP single-photon detectors are today the most frequently used detectors for fibre-based Quantum Key Distribution (QKD) [1,2]. The performance of the QKD-systems greatly depends on the optical properties of its detector, such as quantum efficiency, dead time, dark counts, gating rate, etc., which need to be metrologically characterized to fully grantee the QKD network security. Therefore, several European National Metrological Institutes (NMIs) are putting today great efforts in developing novel measurement methods and calibration facilities, which allow to perform the traceable characterisation of single-photon detectors by using reference standards [3, 4]. From the metrological, and specifically radiometric, point of view, the detection efficiency of the single-photon detector is the main parameter that needs to be traceable to the primary standard for optical power (i.e. the cryogenic radiometer), which is maintained by most of the NMIs. Recently, four European NMIs have carried out a pilot comparison on the detection efficiency of a free-running InGaAs/InP single-photon detector, which main purpose has been to provide a snapshot of the measurement capabilities of the four European NMIs in the field of photon counting detection. The comparison was carried out in the framework of the EMPIR project 14IND05 “Optical metrology for quantum-enhanced secure telecommunication (MIQC2)” at the telecom wavelength of 1550 nm by using different reference standards with independently traceability chains. The results of this comparison, including the different experimental setups, the measurement methods, the traceability chain and the uncertainty evaluation of each participant, will be presented in this conference. References: [1] Akihisa Tomita, et al., “High speed quantum key distribution system”, Optical Fiber Technology, 16, Issue 1, 55-62 (2010). [2] Damien Stucki, et al., “Photon counting for quantum key distribution with peltier cooled InGaAs/InP APDs”, Journal of Modern Optics, 48, Issue 13, 1967-1981 (2001). [3] M. López, et al, “Detection efficiency calibration of single-photon silicon avalanche photodiodes traceable using double attenuator technique, Journal of Modern Optics 62, S21 – S27, 2015. [4] G. Porrovecchio, et al., “Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique”, Metrologia 53, 1115-1122 (2016).
The high-precision self-calibration radiation reference source is currently the research focus of satellite remote sensing calibration. In order to meet the requirements of quantitative applications such as climate monitoring, low-light radiation metering and single photon source radiance measurement, in view of the application requirements and technical requirements of visible to near infrared low-light radiometer, a compact three-channel low-light radiance meter based on correlated photon self-calibration is designed. This design method can improve the measurement accuracy of low light irradiance by using objective physical effect instead of physical standard, reducing the cumulative error caused by standard transfer chain. The absolute calibration of the detector responsivity can be achieved by the spontaneous parameter down-conversion effect, and the absolute radiation observation can be achieved without relying on the external reference. Based on this study, combined with the special application requirements of radiance meter, a numerical model of spectral rate and geometric transmission characteristics of wide spectrum correlated photons is established, and two basic operating modes of self-calibration and radiation observation are determined. The interaction between 355 nm pump source and nonlinear medium generates three-wave mixing, and the correlated photons are generated by class I non-collinear spontaneous parametric downconversion, the combined effect of monochromatic pump photon flow and quantum vacuum noise on non-centrosymmetric nonlinear crystal makes each incident photon spontaneously split into two photons with lower energy with a certain probability, called signal photons and idle photons respectively, they have a wide sptrum distribution from pump wave frequency to lattice resonance frequency. Correlated photon source has the technical characteristics of time and space correlation, natural wide spectrum and absolute reproducibility, so it has high absolute accuracy. Integrated design of self-calibration and radiation observation can monitor and correct changes in response characteristics in real time, maintain long-term stability of response characteristics, and improve traceability and accuracy of observation data. This design method solve the key technologies such as preparation and value transfer of correlated photon sources, suppression of pump stray light, high precision and high efficiency coupling of correlated photons, UV radiation resistance of space single-photon detectors, packaging reinforcement technology of space single-photon detectors,self-calibration and integrated design of radiation observation. The spectral measurement range of the low-light radiance meter is from 460 nm to 1 550 nm, the measurement range of radiance is 1×10-9~1×10-6 W/(cm2·sr·nm). In the design, the integration, miniaturization and modularization of the whole system are considered, and the eight spectral bands are integrated into a three-channel structure, solving the preparation of wide spectrum dependent photon source, optical multiplexing of calibration optical path, radiation measurement, high precision coincidence measurement and full optical path calibration of radiance meter, and achieving high precision radiation observation from visible to near infrared and periodic self-calibration research targets. In the self-calibration mode, the multiplex optical path module periodically introduces the spontaneous parametric down-conversion correlated photons, and the photon counting and coincidence detection module are used to calibrate the absolute quantum efficiency of the three channels. In the radiation observation mode, the multiplex optical path module introduces the low-light level target radiation and obtains the absolute spectral radiance of the observation target in the band of 460~1 550 nm at the same time. The calibration coefficient obtained by the self-calibration mode is used to correct the observation results. The effects of link error limited by radiation reference value transfer, optical decay of optical path and electronic decay of optical path on the measurement accuracy of microradiance are fundamentally solved. The visible near-infrared band adopts free space coupling mode and the short-wave infrared band adopts multi-mode fiber coupling mode. Through design optimization analysis, the focusing spots of the first and second channels meet the 300 μm pixel requirement of Si single photon detector, and the focusing spot of the third channel meets the 62.5 μm core diameter and 0.22 numerical aperture requirement of multi-mode fiber, all of them can be received by the detector photosensitive surface, meeting the design objectives. The method based on correlated photon calibration does not need to trace the high-precision primary standard in the laboratory and the lengthy standard transfer chain. By using the correlated photon generated in the process of parametric down-conversion, the calibration source of time, space and polarization can be obtained, and the high-precision observation of the low-light spectrum radiance from visible to near infrared band can be realized. The solution to the scientific problem of low-light observation instrument in space platform measurement can obtain higher calibration accuracy, and play an important role in climate monitoring, low-light radiation metrology, single-photon source radiance measurement and so on.