Physical Review Letters

Liquid-Nitrogen-Cooled 40 Ca + Ion Optical Clock with a Systematic Uncertainty of 4.4 × 10 − 19

Bao-Lin 宝林 Zhang 张, Zixiao Ma, Yao Huang, Hui-Li Han, Ru-ming Hu, Yuzhuo Wang, Hua-qing Zhang, Li-Yan Tang, Ting-Yun Shi, Guan Hua, Kelin Gao

Published Dec 22, 2025• 13 citations
Publisher

Abstract

We report a single-ion optical clock based on the 4S_{1/2}→3D_{5/2} transition of the ^{40}Ca^{+} ion, operated in a liquid nitrogen cryogenic environment, achieving a total systematic uncertainty of 4.4×10^{-19}. We employ a refined temperature evaluation scheme to reduce the frequency uncertainty due to blackbody radiation, and 3D sideband cooling to minimize the second-order Doppler shift. We have precisely determined the average Zeeman coefficient of the ^{40}Ca^{+} clock transition to be 14.345(15) Hz/mT^{2}, thereby significantly reducing the quadratic Zeeman shift uncertainty. Moreover, the cryogenic environment enables the lowest reported heating rate due to ambient electric field noise in trapped-ion optical clocks.

DOI
10.1103/vngc-c1xv

Related papers

A liquid nitrogen-cooled Ca+ optical clock with systematic uncertainty of 3×10-18

Yao Huang, Baolin Zhang, Mengyan Zeng +6 more

Abstract Here we present a liquid nitrogen-cooled Ca+ optical clock with an overall systematic uncertainty of 3×10-18. In contrast with the room-temperature Ca+ optical clock that we have reported previously, the temperature of the blackbody radiation (BBR) shield in vacuum has been reduced to 82(5) K using liquid nitrogen. An ion trap with a lower heating rate and improved cooling lasers were also introduced. This allows cooling the ion temperature to the Doppler cooling limit during the clock operation, and the systematic uncertainty due to the ion’s secular (thermal) motion is reduced to < 1×10-18. The uncertainty due to the probe laser light shift and the servo error are also reduced to < 1×10-19 and 4×10-19 with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two was measured with a fractional statistical uncertainty of 7×10-18. The differential BBR shift was used to calculate the static differential polarizability, and it was found in excellent agreement with our previous measurement with a different method. This work suggests that the BBR shift of optical clocks can be well suppressed in a liquid nitrogen environment. This is advantageous because conventional liquid-helium cryogenic systems for optical clocks are more expensive and complicated. Moreover, the proposed system can be used to suppress the BBR shift significantly in other types of optical clocks such as Yb+, Sr+, Yb, Sr, etc.

arXiv:2103.08913•Mar 16, 2021•10 citations

Liquid-Nitrogen-Cooled Ca + Optical Clock with Systematic Uncertainty of 3×10−18

Yao Huang, Baolin Zhang, Mengyan Zeng +7 more

We present a liquid-nitrogen-cooled $\mathrm{Ca}$${}^{+}$ optical clock with an overall systematic uncertainty of $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. In contrast to the room-temperature $\mathrm{Ca}$${}^{+}$ optical clock that we have reported previously, the cryogenic black-body radiation (BBR) shield in vacuum is cooled to $82\ifmmode\pm\else\textpm\fi{}5$ K using liquid nitrogen. We also implement an ion trap with a reduced heating rate and improved laser cooling. This allows the ion temperature to fall to the Doppler-cooling limit during the clock operation and the systematic uncertainty associated with the secular (thermal) motion of the ion is reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The uncertainty arising from the probe laser light shift and the servo error is also reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ and $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two is determined with a fractional statistical uncertainty of $7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The differential BBR shift is used to calculate the static differential polarizability and the result is found to be in excellent agreement with our previous measurement using a different method. This work suggests that the BBR shift of optical clocks can be suppressed well in a liquid-nitrogen environment. Systems similar to what is presented here can also be used to suppress the BBR shift significantly in other types of optical clocks, such as $\mathrm{Yb}$${}^{+}$, $\mathrm{Sr}$${}^{+}$, $\mathrm{Yb}$, Sr, etc.

Physical Review Applied•Mar 15, 2022•82 citations

Towards a transportable Ca$^+$ optical clock with a systematic uncertainty of $4.8\times 10^{-18}$

Mengyan Zeng, Yao Tien Huang, Baolin Zhang +8 more

We present a compact, long-term nearly continuous operation of a room-temperature Ca$^+$ optical clock setup towards a transportable clock, achieving an overall systematic uncertainty of $4.8\times 10^{-18}$ and an uptime rate of 97.8% over an 8-day period. The active liquid-cooling scheme is adopted, combined with the precise temperature measurement with 13 temperature sensors both inside and outside the vacuum chamber to ensure the accurate evaluation of the thermal environment for the optical clock. The environmental temperature uncertainty is evaluated as 293.31(0.4) K, corresponding to a blackbody radiation (BBR) frequency shift uncertainty of $4.6\times 10^{-18}$, which is reduced more than two times compared to our previous work. Through the frequency comparison between the room temperature Ca$^+$ optical clock and a cryogenic Ca$^+$ optical clock, the overall uncertainty of the clock comparison is $7.5\times 10^{-18}$, including a statistic uncertainty of $4.9\times 10^{-18}$ and a systematic uncertainty of $5.7\times 10^{-18}$. This work provides a set of feasible implementations for high-precision transportable ion optical clocks.

arXiv:2303.07566•Mar 14, 2023•0 citations

A cryogenic radio-frequency ion trap for a 40Ca+ optical clock

Mengyan Zeng, Yao 垚 Huang 黄, Baolin 宝林 Zhang 张 +6 more

A liquid-nitrogen cryogenic 40Ca+ optical clock is presented that is designed to greatly reduce the blackbody radiation (BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the liquid-nitrogen container, keeping the ions in a cryogenic environment at liquid-nitrogen temperature. Compared with the first design in our previous work, many improvements have been made to increase the performance. The liquid-nitrogen maintenance time has been increased by about three times by increasing the volume of the liquid-nitrogen container; the trap position recovery time after refilling the liquid-nitrogen container has been decreased more than three times by using a better fixation scheme in the liquid-nitrogen container; and the magnetic field noise felt by the ions has been decreased more than three times by a better design of the magnetic shielding system. These optimizations make the scheme for reducing the BBR shift uncertainty of liquid-nitrogen-cooled optical clocks more mature and stable, and develop a stable lock with a narrower linewidth spectrum, which would be very beneficial for further reducing the overall systematic uncertainty of optical clocks.

Chinese Physics B•Mar 28, 2023•2 citations

Evaluation of the performance of a ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ optical clock

Kaifeng Cui, Sijia Chao, Chenglong Sun +6 more

We report the evaluation of the systematic shifts and the total uncertainty of an ${}^{27}\textrm{Al}^+$ optical clock sympathetically cooled by a ${}^{40}\textrm{Ca}^+$ ion. Due to its relatively low Doppler cooling limit and the suitability of its mass ratio to the ${}^{27}\textrm{Al}^+$ ion, the time dilation shift of the secular motion of our ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ clock is smaller than the shift of a ${}^{25}\textrm{Mg}^+ - {}^{27}\textrm{Al}^+$ clock. The total systematic uncertainty of our ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ quantum logic clock has been estimated to be $7.6 \times 10^{-18}$, which was mainly limited by the uncertainty of the quadratic Zeeman shift.

•Dec 10, 2020•0 citations

Progress on the 40Ca+ ion optical clock*

Baolin Zhang, Yao Huang, Huaqing Zhang +4 more

Progress of the 40Ca+ ion optical clock based on the 42S1/2 – 3d 2D5/2 electric quadrupole transition is reported. By setting the drive frequency to the “magic” frequency Ω 0, the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10−19 level. By precisely measuring the differential static scalar polarizability Δα 0, the uncertainty due to the blackbody radiation (BBR) shift (coefficient) is reduced to the 10−19 level. With the help of a second-order integrating servo algorithm, the uncertainty due to the servo error is reduced to the 10−18 level. The total fractional uncertainty of the 40Ca+ ion optical clock is then improved to 2.2× 10−17, whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations. The state preparation is introduced together with improvements in the pulse sequence, and furthermore, a better signal to noise ratio (SNR) and less dead time are achieved. The clock stability of a single clock is improved to 4.8 × 10 − 15 / τ ( in seconds ) .

Chinese Physics B•May 19, 2020•18 citations
We report a single-ion optical clock based on the 4S_{1/2}→3D_{5/2} transition of the ^{40}Ca^{+} ion, operated in a liquid nitrogen cryogenic environment, achieving a total systematic uncertainty of 4.4×10^{-19}. We employ a refined temperature evaluation scheme to reduce the frequency uncertainty due to blackbody radiation, and 3D sideband cooling to minimize the second-order Doppler shift. We have precisely determined the average Zeeman coefficient of the ^{40}Ca^{+} clock transition to be 14.345(15) Hz/mT^{2}, thereby significantly reducing the quadratic Zeeman shift uncertainty. Moreover, the cryogenic environment enables the lowest reported heating rate due to ambient electric field noise in trapped-ion optical clocks.
Abstract Here we present a liquid nitrogen-cooled Ca+ optical clock with an overall systematic uncertainty of 3×10-18. In contrast with the room-temperature Ca+ optical clock that we have reported previously, the temperature of the blackbody radiation (BBR) shield in vacuum has been reduced to 82(5) K using liquid nitrogen. An ion trap with a lower heating rate and improved cooling lasers were also introduced. This allows cooling the ion temperature to the Doppler cooling limit during the clock operation, and the systematic uncertainty due to the ion’s secular (thermal) motion is reduced to < 1×10-18. The uncertainty due to the probe laser light shift and the servo error are also reduced to < 1×10-19 and 4×10-19 with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two was measured with a fractional statistical uncertainty of 7×10-18. The differential BBR shift was used to calculate the static differential polarizability, and it was found in excellent agreement with our previous measurement with a different method. This work suggests that the BBR shift of optical clocks can be well suppressed in a liquid nitrogen environment. This is advantageous because conventional liquid-helium cryogenic systems for optical clocks are more expensive and complicated. Moreover, the proposed system can be used to suppress the BBR shift significantly in other types of optical clocks such as Yb+, Sr+, Yb, Sr, etc.
We present a liquid-nitrogen-cooled Ca\mathrm{Ca}Ca+{}^{+}+ optical clock with an overall systematic uncertainty of $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. In contrast to the room-temperature Ca\mathrm{Ca}Ca+{}^{+}+ optical clock that we have reported previously, the cryogenic black-body radiation (BBR) shield in vacuum is cooled to $82\ifmmode\pm\else\textpm\fi{}5$ K using liquid nitrogen. We also implement an ion trap with a reduced heating rate and improved laser cooling. This allows the ion temperature to fall to the Doppler-cooling limit during the clock operation and the systematic uncertainty associated with the secular (thermal) motion of the ion is reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The uncertainty arising from the probe laser light shift and the servo error is also reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ and $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two is determined with a fractional statistical uncertainty of $7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The differential BBR shift is used to calculate the static differential polarizability and the result is found to be in excellent agreement with our previous measurement using a different method. This work suggests that the BBR shift of optical clocks can be suppressed well in a liquid-nitrogen environment. Systems similar to what is presented here can also be used to suppress the BBR shift significantly in other types of optical clocks, such as Yb\mathrm{Yb}Yb+{}^{+}+, Sr\mathrm{Sr}Sr+{}^{+}+, Yb\mathrm{Yb}Yb, Sr, etc.
Towards a transportable Ca+^++ optical clock with a systematic uncertainty of 4.8×10−184.8\times 10^{-18}4.8×10−18
We present a compact, long-term nearly continuous operation of a room-temperature Ca+^++ optical clock setup towards a transportable clock, achieving an overall systematic uncertainty of 4.8×10−184.8\times 10^{-18}4.8×10−18 and an uptime rate of 97.8% over an 8-day period. The active liquid-cooling scheme is adopted, combined with the precise temperature measurement with 13 temperature sensors both inside and outside the vacuum chamber to ensure the accurate evaluation of the thermal environment for the optical clock. The environmental temperature uncertainty is evaluated as 293.31(0.4) K, corresponding to a blackbody radiation (BBR) frequency shift uncertainty of 4.6×10−184.6\times 10^{-18}4.6×10−18, which is reduced more than two times compared to our previous work. Through the frequency comparison between the room temperature Ca+^++ optical clock and a cryogenic Ca+^++ optical clock, the overall uncertainty of the clock comparison is 7.5×10−187.5\times 10^{-18}7.5×10−18, including a statistic uncertainty of 4.9×10−184.9\times 10^{-18}4.9×10−18 and a systematic uncertainty of 5.7×10−185.7\times 10^{-18}5.7×10−18. This work provides a set of feasible implementations for high-precision transportable ion optical clocks.
A liquid-nitrogen cryogenic 40Ca+ optical clock is presented that is designed to greatly reduce the blackbody radiation (BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the liquid-nitrogen container, keeping the ions in a cryogenic environment at liquid-nitrogen temperature. Compared with the first design in our previous work, many improvements have been made to increase the performance. The liquid-nitrogen maintenance time has been increased by about three times by increasing the volume of the liquid-nitrogen container; the trap position recovery time after refilling the liquid-nitrogen container has been decreased more than three times by using a better fixation scheme in the liquid-nitrogen container; and the magnetic field noise felt by the ions has been decreased more than three times by a better design of the magnetic shielding system. These optimizations make the scheme for reducing the BBR shift uncertainty of liquid-nitrogen-cooled optical clocks more mature and stable, and develop a stable lock with a narrower linewidth spectrum, which would be very beneficial for further reducing the overall systematic uncertainty of optical clocks.
Evaluation of the performance of a 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ optical clock
We report the evaluation of the systematic shifts and the total uncertainty of an 27Al+{}^{27}\textrm{Al}^+27Al+ optical clock sympathetically cooled by a 40Ca+{}^{40}\textrm{Ca}^+40Ca+ ion. Due to its relatively low Doppler cooling limit and the suitability of its mass ratio to the 27Al+{}^{27}\textrm{Al}^+27Al+ ion, the time dilation shift of the secular motion of our 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ clock is smaller than the shift of a 25Mg+−27Al+{}^{25}\textrm{Mg}^+ - {}^{27}\textrm{Al}^+25Mg+−27Al+ clock. The total systematic uncertainty of our 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ quantum logic clock has been estimated to be 7.6×10−187.6 \times 10^{-18}7.6×10−18, which was mainly limited by the uncertainty of the quadratic Zeeman shift.
Progress of the 40Ca+ ion optical clock based on the 42S1/2 – 3d 2D5/2 electric quadrupole transition is reported. By setting the drive frequency to the “magic” frequency Ω 0, the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10−19 level. By precisely measuring the differential static scalar polarizability Δα 0, the uncertainty due to the blackbody radiation (BBR) shift (coefficient) is reduced to the 10−19 level. With the help of a second-order integrating servo algorithm, the uncertainty due to the servo error is reduced to the 10−18 level. The total fractional uncertainty of the 40Ca+ ion optical clock is then improved to 2.2× 10−17, whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations. The state preparation is introduced together with improvements in the pulse sequence, and furthermore, a better signal to noise ratio (SNR) and less dead time are achieved. The clock stability of a single clock is improved to 4.8 × 10 − 15 / τ ( in seconds ) .