Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

VTT MIKESin Sr88+ -ionikellon tilastollisen ja systemaattisen epävarmuuden pienentäminen

Seppäläinen, Lauri

Published Dec 14, 2021• 0 citations
OpenAlex

Abstract

Optical single-ion clocks offer a novel way to create a so-called frequency standard, a device for measuring frequencies, with unprecedented accuracy. These standards are often called clocks for simplicity. In recent years, this new approach has been steadily pushing the uncertainty records of atomic clocks well beyond those of more traditional microwave domain implementations. Here, optical clocks refer to atomic clocks where the oscillator of the clock is a laser. In this work, we examine the current state of the VTT MIKES Sr88+ single-ion optical clock and present a new approach to probing the reference ion. The greatest improvement in the systematic uncertainty of the clock has been the new helical resonator, which allows us to trap the ion such that is moves at a so-called ``magic frequency''. At this frequency, motion-related shifts in the reference transition of the ion are minimized. In addition, a bichromatic probing scheme is presented and its stability compared in simulation to a more traditional probing sequence. This new probing sequence is shown to offer an increase in stability in use cases where ion state preparation is not possible. With the simulation, we show that the bichromatic sampling sequence increases the stability of a clock by a factor of 1/\sqrt{2} in the ideal case and a factor of 0.76 in a realistic case, as predicted by theory. To provide a look into the state of the current clock system and near-future upgrades we analyze the results from a 30-hour clock run (continuous operation of the clock) in late 2020. In the clockrun, we reach a stability, as measured by the Allan deviation, extending into the low 10^(-15) range.

Related papers

Sr88+ single-ion optical clock with a stability approaching the quantum projection noise limit

P. Dubé, Alan A. Madej, Andrew D. Shiner +1 more

A number of optical frequency standards have been evaluated with fractional uncertainties between ${10}^{\ensuremath{-}17}$ and ${10}^{\ensuremath{-}18}$. Reduction of the statistical uncertainty of a clock comparison to this level is challenging, requiring the best possible stability to avoid excessively long averaging times. We report recent improvements of our $^{88}\mathrm{Sr}{}^{+}$ single-ion standard that have reduced its 1-s Allan deviation from $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, yielding an order of magnitude decrease in averaging time for a given statistical uncertainty level. Among the improvements made are the implementation of a clear-out laser that transfers the ion from the metastable state to the ground state at each cycle, followed by a state preparation step that transfers the ion to the ground-state magnetic sublevel of the probed transition. With these changes, the ion clock transition interacts with the probe laser at every interrogation cycle. The stability of our optical standard is essentially limited by the quantum projection noise for pulse lengths up to $\ensuremath{\approx}100$ ms.

Physical Review A•Oct 22, 2015•51 citations

Extended precision measurements of a strontium single ion optical frequency standard and its development as an optical atomic clock

Alan A. Madej, P. Dubé, J. E. Bernard +4 more

We describe the recent advances of the NRC single ion based optical frequency standard using the 445-THz S-D transition in88Sr+. Laser cooled confinement and probing of the clock transition has been obtained for periods exceeding 24 hours showing high levels of stability. Spectral resolutions better than 5 Hz at 445 THz have been obtained. Work is described on the development of an improved ion trap system and the continuous linkage of the optical frequency to the RF domain using a fiber based frequency comb.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•0 citations

Spectroscopic characterization of ion motion for an optical clock based on Coulomb crystals

Keller, Jonas

Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.

•Jan 1, 2015•5 citations

Quantum projection noise limited stability of a88Sr+ atomic clock

Bin Jian, P. Dubé, Alan A. Madej

The evaluated accuracy of a single trapped 88 Sr + ion clock referenced to the 5s 2 S 1/2 - 4d 2 D 5/2 transition at 445 THz at the National Research Council of Canada has reached 1.2 x 10 -17 over recent years. On the other hand, the stability of an atomic clock determines how long the signals from two similar clocks have to be compared to reach a given level of uncertainty. Here, we report on the improvement of the stability of NRC's 88 Sr + single ion clock by reducing the Allan deviation from 1 x 10 -14 to 3 x 10 -15 at 1 second averaging time. This is done by the implementation of a clear out laser that transfers the ion from the metastable state to the ground state at each cycle, followed by a state-preparation step that transfers the ion to the desired ground state magnetic sublevel of the probed transition.

Journal of Physics Conference Series•Jun 1, 2016•2 citations

High-Stability Single-Ion Clock with 5.5 × 10 − 19 Systematic Uncertainty

Mason C. Marshall, Daniel A. Rodriguez Castillo, Willa J. Arthur-Dworschack +10 more

We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.

arXiv:2504.13071•Physical Review Letters•Jul 14, 2025•91 citations

Improvements to a Strontium Optical Lattice Clock

Rees L. McNally

In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.

•Jan 1, 2014•0 citations
Optical single-ion clocks offer a novel way to create a so-called frequency standard, a device for measuring frequencies, with unprecedented accuracy. These standards are often called clocks for simplicity. In recent years, this new approach has been steadily pushing the uncertainty records of atomic clocks well beyond those of more traditional microwave domain implementations. Here, optical clocks refer to atomic clocks where the oscillator of the clock is a laser. In this work, we examine the current state of the VTT MIKES Sr88+ single-ion optical clock and present a new approach to probing the reference ion. The greatest improvement in the systematic uncertainty of the clock has been the new helical resonator, which allows us to trap the ion such that is moves at a so-called ``magic frequency''. At this frequency, motion-related shifts in the reference transition of the ion are minimized. In addition, a bichromatic probing scheme is presented and its stability compared in simulation to a more traditional probing sequence. This new probing sequence is shown to offer an increase in stability in use cases where ion state preparation is not possible. With the simulation, we show that the bichromatic sampling sequence increases the stability of a clock by a factor of 1/\sqrt{2} in the ideal case and a factor of 0.76 in a realistic case, as predicted by theory. To provide a look into the state of the current clock system and near-future upgrades we analyze the results from a 30-hour clock run (continuous operation of the clock) in late 2020. In the clockrun, we reach a stability, as measured by the Allan deviation, extending into the low 10^(-15) range.
A number of optical frequency standards have been evaluated with fractional uncertainties between ${10}^{\ensuremath{-}17}$ and ${10}^{\ensuremath{-}18}$. Reduction of the statistical uncertainty of a clock comparison to this level is challenging, requiring the best possible stability to avoid excessively long averaging times. We report recent improvements of our 88Sr+^{88}\mathrm{Sr}{}^{+}88Sr+ single-ion standard that have reduced its 1-s Allan deviation from $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, yielding an order of magnitude decrease in averaging time for a given statistical uncertainty level. Among the improvements made are the implementation of a clear-out laser that transfers the ion from the metastable state to the ground state at each cycle, followed by a state preparation step that transfers the ion to the ground-state magnetic sublevel of the probed transition. With these changes, the ion clock transition interacts with the probe laser at every interrogation cycle. The stability of our optical standard is essentially limited by the quantum projection noise for pulse lengths up to $\ensuremath{\approx}100$ ms.
We describe the recent advances of the NRC single ion based optical frequency standard using the 445-THz S-D transition in88Sr+. Laser cooled confinement and probing of the clock transition has been obtained for periods exceeding 24 hours showing high levels of stability. Spectral resolutions better than 5 Hz at 445 THz have been obtained. Work is described on the development of an improved ion trap system and the continuous linkage of the optical frequency to the RF domain using a fiber based frequency comb.
Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.
The evaluated accuracy of a single trapped 88 Sr + ion clock referenced to the 5s 2 S 1/2 - 4d 2 D 5/2 transition at 445 THz at the National Research Council of Canada has reached 1.2 x 10 -17 over recent years. On the other hand, the stability of an atomic clock determines how long the signals from two similar clocks have to be compared to reach a given level of uncertainty. Here, we report on the improvement of the stability of NRC's 88 Sr + single ion clock by reducing the Allan deviation from 1 x 10 -14 to 3 x 10 -15 at 1 second averaging time. This is done by the implementation of a clear out laser that transfers the ion from the metastable state to the ground state at each cycle, followed by a state-preparation step that transfers the ion to the desired ground state magnetic sublevel of the probed transition.
We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.
In 2013, for the first time ever, a many-atom optical lattice clock surpassed single ion clocks as the most stable, and accurate frequency standard in existence. Since this first result, continued improvements to the clock's accuracy and stability have been made. This work will focus on two of these major improvements. Firstly the frequency uncertainty was brought down to 2.5*10^-18, thanks in part to an accurate determination of the black body radiation shift, based on better characterization of the level structure of 87Sr. Secondly, a control modification will be demonstrated which provides 20% reduction in the standard deviation for the clock's frequency under differential measurement schemes. This represents a new record for clock accuracy, pushing performance towards the 10^-19 level.