Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Extended precision measurements of a strontium single ion optical frequency standard and its development as an optical atomic clock

Alan A. Madej, P. Dubé, J. E. Bernard, Andrew D. Shiner, L. Marmet, J. Jiang, David J. Jones

Published Jun 1, 2008• 0 citations
Publisher

Abstract

We describe the recent advances of the NRC single ion based optical frequency standard using the 445-THz S-D transition in88Sr+. Laser cooled confinement and probing of the clock transition has been obtained for periods exceeding 24 hours showing high levels of stability. Spectral resolutions better than 5 Hz at 445 THz have been obtained. Work is described on the development of an improved ion trap system and the continuous linkage of the optical frequency to the RF domain using a fiber based frequency comb.

DOI
10.1109/cpem.2008.4574668

Related papers

Recent progress on the NRC 88Sr+ single-ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +4 more

We report our recent progress made with the NRC88Sr+single-ion optical frequency standard. The long-term operation of the standard was improved by actively stabilizing the cooling, repump and clearout laser sources, and by using a femtosecond fiber laser frequency comb to link the probe laser frequency to the microwave time standards. With the femtosecond fiber comb, we have demonstrated continuous operation for a period of eight days and continuous measurement of the probe laser source for three days. Micromotion shifts have been the dominant source of uncertainty in our rf Paul trap because laser beam access is only possible along one axis in the current design. With the aim of reducing to a minimum these shifts, we have constructed an endcap trap designed for minimization of micromotion along three orthogonal axes. We report on the successful trapping of single ions with this endcap trap. Since electrode contamination during trap loading can also induce micromotion shifts as a result of evolving patch potentials, we have increased the trap loading efficiency with photo-ionization.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2010•2 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations

Indium single ion optical frequency standard

T. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•3 citations

Indium single-ion optical frequency standard

Thomas P. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

Single laser-cooled ions in radiofrequency traps can serve as the basis for highly stable optical frequency standards. Here we present recent results on In+, using the 1S0 yields 3P0 line at 236.5 nm wavelength as the clock transition. This resonance has a natural linewidth of only 0.82 Hz and systematic shifts should be controllable at the mHz level. A single indium ion is stored in a miniature Paul- Straubel trap and laser cooled to a temperature of about 100 (mu) K. The clock transition is excited using a frequency quadrupled 946 nm Nd:YAG laser. A fractional resolution of 1.3 (DOT) 10-13 has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute optical frequency of the clock transition has been measured with an uncertainty being less than 3 (DOT) 10-13 using a frequency chain and a methane-stabilized HeNe laser that was calibrated with a cesium clock.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•0 citations

Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion

Helen S. Margolis, G. P. Barwood, Guozheng Huang +4 more

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.

Science•Nov 18, 2004•302 citations

High Precision Spectroscopy of Strontium in an Optical Lattice: Towards a New Standard for Frequency and Time

Martin M. Boyd

Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise

•Jan 1, 2007•36 citations
We describe the recent advances of the NRC single ion based optical frequency standard using the 445-THz S-D transition in88Sr+. Laser cooled confinement and probing of the clock transition has been obtained for periods exceeding 24 hours showing high levels of stability. Spectral resolutions better than 5 Hz at 445 THz have been obtained. Work is described on the development of an improved ion trap system and the continuous linkage of the optical frequency to the RF domain using a fiber based frequency comb.
We report our recent progress made with the NRC88Sr+single-ion optical frequency standard. The long-term operation of the standard was improved by actively stabilizing the cooling, repump and clearout laser sources, and by using a femtosecond fiber laser frequency comb to link the probe laser frequency to the microwave time standards. With the femtosecond fiber comb, we have demonstrated continuous operation for a period of eight days and continuous measurement of the probe laser source for three days. Micromotion shifts have been the dominant source of uncertainty in our rf Paul trap because laser beam access is only possible along one axis in the current design. With the aim of reducing to a minimum these shifts, we have constructed an endcap trap designed for minimization of micromotion along three orthogonal axes. We report on the successful trapping of single ions with this endcap trap. Since electrode contamination during trap loading can also induce micromotion shifts as a result of evolving patch potentials, we have increased the trap loading efficiency with photo-ionization.
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.
A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.
Single laser-cooled ions in radiofrequency traps can serve as the basis for highly stable optical frequency standards. Here we present recent results on In+, using the 1S0 yields 3P0 line at 236.5 nm wavelength as the clock transition. This resonance has a natural linewidth of only 0.82 Hz and systematic shifts should be controllable at the mHz level. A single indium ion is stored in a miniature Paul- Straubel trap and laser cooled to a temperature of about 100 (mu) K. The clock transition is excited using a frequency quadrupled 946 nm Nd:YAG laser. A fractional resolution of 1.3 (DOT) 10-13 has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute optical frequency of the clock transition has been measured with an uncertainty being less than 3 (DOT) 10-13 using a frequency chain and a methane-stabilized HeNe laser that was calibrated with a cesium clock.
The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.
Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise