Cryogenic Optical Lattice Clock with Low 10-20 Blackbody Radiation Stark Uncertainty

Hassan, Youssef Salahuddin Sayed

Published Apr 14, 2025• 0 citations
OpenAlex

Abstract

Controlling the Stark perturbation from ambient thermal radiation is key to advancing the performance of many atomic frequency standards. This thermal radiation perturbs the atomic energy levels, inducing a Stark shift to the clock frequency conventionally known as the BBR shift. For over four decades, the BBR shift has been a persistent challenge in the pursuit of better atomic clock performance. For room-temperature optical lattice clocks (OLCs) based on Yb and Sr, the BBR shift represents the largest uncanceled systematic frequency shift while typically also constituting the largest source of uncertainty in these state-of-the-art clocks at the ≈ 1 × 10−18 level. In this thesis, I report on the design, assembly and integration of a BBR enclosure, or “shield,” that achieves an unprecedented BBR shift uncertainty of 1.7 × 10−20 by furnishing the interrogated atoms with a near-ideal BBR environment at a cryogenic temperature, while still allowing all the critical quantum control functions required for clock operation. Also, I present a novel lattice loading technique, known as ratchet loading, which enables programmable control over the spatial distribution of ultra-cold atoms confined in an optical lattice. This method allows for the loading of a large number of atoms, effectively reducing quantum projection noise (QPN) while also mitigating frequency shifts caused by atomic interactions. Additionally, ratchet loading facilitates the creation of spatially resolved atomic ensembles along the lattice, making it particularly useful for lattice light shift measurements and potentially advantageous for emerging techniques that probe atomic coherence beyond the local oscillator (LO) coherence time. With the near-elimination of blackbody radiation (BBR) uncertainty and improved clock stability for systematic evaluations, the realization of a mid- to low-10−19 uncertainty Yb optical lattice clock is now more attainable than ever.

Related papers

Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty

K. Beloy, N. Hinkley, Nate Phillips +7 more

The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of 5.5×10(-19). Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now 1×10(-18). Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.

arXiv:1412.1029•Physical Review Letters•Dec 24, 2014•137 citations

87Sr optical lattice clocks at JILA

Michael J. Martin, Matthew D. Swallows, Travis Nicholson +5 more

We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations

Combined atomic clock with blackbody-radiation-shift-induced instability below 10−19 under natural environment conditions

Valeriy I. Yudin, А. В. Тайченачев, M. Yu. Basalaev +4 more

Abstract We develop a method of synthetic frequency generation to construct an atomic clock with blackbody radiation (BBR) shift uncertainties below 10−19 at environmental conditions with a very low level of temperature control. The proposed method can be implemented for atoms and ions, which have two different clock transitions with frequencies ν 1 and ν 2 allowing to form a synthetic reference frequency ν syn = (ν 1 − ɛν 2)/(1 − ɛ), which is absent in the spectrum of the involved atoms or ions. Calibration coefficient ɛ can be chosen such that the temperature dependence of the BBR shift for the synthetic frequency ν syn has a local extremum at an arbitrary operating temperature T 0. This leads to a weak sensitivity of BBR shift with respect to the temperature variations near operating temperature T 0. As a specific example, the Yb+ ion is studied in detail, where the utilized optical clock transitions are of electric quadrupole (S → D) and octupole (S → F) type. In this case, temperature variations of ±7 K lead to BBR shift uncertainties of less than 10−19, showing the possibility to construct ultra-precise combined atomic clocks (including portable ones) without the use of cryogenic techniques.

New Journal of Physics•Jan 29, 2021•8 citations

A liquid nitrogen-cooled Ca+ optical clock with systematic uncertainty of 3×10-18

Yao Huang, Baolin Zhang, Mengyan Zeng +6 more

Abstract Here we present a liquid nitrogen-cooled Ca+ optical clock with an overall systematic uncertainty of 3×10-18. In contrast with the room-temperature Ca+ optical clock that we have reported previously, the temperature of the blackbody radiation (BBR) shield in vacuum has been reduced to 82(5) K using liquid nitrogen. An ion trap with a lower heating rate and improved cooling lasers were also introduced. This allows cooling the ion temperature to the Doppler cooling limit during the clock operation, and the systematic uncertainty due to the ion’s secular (thermal) motion is reduced to < 1×10-18. The uncertainty due to the probe laser light shift and the servo error are also reduced to < 1×10-19 and 4×10-19 with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two was measured with a fractional statistical uncertainty of 7×10-18. The differential BBR shift was used to calculate the static differential polarizability, and it was found in excellent agreement with our previous measurement with a different method. This work suggests that the BBR shift of optical clocks can be well suppressed in a liquid nitrogen environment. This is advantageous because conventional liquid-helium cryogenic systems for optical clocks are more expensive and complicated. Moreover, the proposed system can be used to suppress the BBR shift significantly in other types of optical clocks such as Yb+, Sr+, Yb, Sr, etc.

arXiv:2103.08913•Mar 16, 2021•10 citations

Tackling the blackbody shift in a strontium optical lattice clock

Thomas Middelmann, Christian Lisdat, Stephan Falke +3 more

A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock transition and, secondly, by interrogating the atoms in a cryogenic environment. Both approaches rely on transporting ultracold atoms over several cm within a probe cycle. We evaluate this approach of mechanically moving the optical lattice and conclude that it is feasible to transport the atoms over 50 mm within 300 ms. With this transport a dc Stark shift measurement will allow to reduce the contribution of the blackbody radiation to the fractional uncertainty below 2 * 10^-17 at room temperature by improving the shift coefficient known only from atomic structure calculations up to now. We propose a cryogenic environment at 77 K that will reduce this contribution to few parts in 10^-18.

arXiv:1009.2017•Sep 10, 2010•2 citations

Bestimmung des Einflusses thermischer Strahlung auf eine optische Strontium-Gitteruhr

Thomas Middelmann

Optical clocks have the potential to be 100 times more accurate than current best cesium atomic clocks within a fraction of the averaging time.This corresponds to a fractional uncertainty of the clock frequency on the level of 10 -18 and requires highaccuracy knowledge of systematic frequency shifts, such that they can be avoided or corrected for.In strontium optical lattice clocks an ensemble of ultracold strontium atoms is conned in an optical lattice, to allow for spectroscopy of the reference transition 5s 2 1 S 0 5s5p 3 P 0 in the Lamb-Dicke regime.The by far largest systematic frequency shift of the strontium clock transition is caused by its high sensitivity to blackbody radiation (BBR).The knowledge of the resulting frequency shift limited the achievable clock uncertainty to about 1 × 10 -16 .In this thesis for the rst time an experimental approach was followed, to determine the sensitivity of the strontium clock transition to blackbody radiation.At an environmental temperature of 300 K the resulting frequency shift corresponds to 2.277 8(23) Hz.The achieved uncertainty contributes with 5 × 10 -18 to the fractional systematic uncertainty of the clock frequency.The determination is based on a precision measurement of the dierence of static polarizabilities of the two clock states ∆α dc = α(5s5p 3 P 0 ) -α(5s 2 1 S 0 ) = 4.078 73(11) × 10 -39 Cm 2 /V.For this the dc Stark shift of the clock transition has been measured in the accurately known electric eld of a precision plate capacitor, which has been developed in this work.The attained static polarizability dierence ∆α dc corresponds to the rst term of a power series of the sensitivity to BBR.Higher orders are accumulated as dynamic part of the BBR shift.Which has been modelled using ∆α dc and experimental data for other atomic properties.To interrogate the ultracold atoms in the electric eld a novel transport technique has been developed, which uses the magic wavelength (813 nm) optical lattice to convey the atoms.For this, the interference pattern is translated together with the foci of the far-detuned lattice beams, by simultaneous translation of the lattice optics.In this way ultracold atoms have been transported within 250 ms over 5 cm, or several Rayleigh ranges respectively without signicant atom loss or heating.In the course of this work the rst frequency measurement with the strontium lattice clock of Physikalisch-Technischen Bundesanstalt (PTB) has been performed.The frequency of the 87 Sr clock transition was measured to be 429 228 004 229 872.9(5)Hz.The strontium lattice clock itself contributed with 1.5 × 10 -16 to the overall fractional uncertainty.Furthermore the thermal radiation eld in a cryogenic blackbody environment was modelled and a draft of a corresponding environment of the atoms was designed, which is suitable to be implemented in the strontium lattice clock of PTB.

•Jan 1, 2013•0 citations
Controlling the Stark perturbation from ambient thermal radiation is key to advancing the performance of many atomic frequency standards. This thermal radiation perturbs the atomic energy levels, inducing a Stark shift to the clock frequency conventionally known as the BBR shift. For over four decades, the BBR shift has been a persistent challenge in the pursuit of better atomic clock performance. For room-temperature optical lattice clocks (OLCs) based on Yb and Sr, the BBR shift represents the largest uncanceled systematic frequency shift while typically also constituting the largest source of uncertainty in these state-of-the-art clocks at the ≈ 1 × 10−18 level. In this thesis, I report on the design, assembly and integration of a BBR enclosure, or “shield,” that achieves an unprecedented BBR shift uncertainty of 1.7 × 10−20 by furnishing the interrogated atoms with a near-ideal BBR environment at a cryogenic temperature, while still allowing all the critical quantum control functions required for clock operation. Also, I present a novel lattice loading technique, known as ratchet loading, which enables programmable control over the spatial distribution of ultra-cold atoms confined in an optical lattice. This method allows for the loading of a large number of atoms, effectively reducing quantum projection noise (QPN) while also mitigating frequency shifts caused by atomic interactions. Additionally, ratchet loading facilitates the creation of spatially resolved atomic ensembles along the lattice, making it particularly useful for lattice light shift measurements and potentially advantageous for emerging techniques that probe atomic coherence beyond the local oscillator (LO) coherence time. With the near-elimination of blackbody radiation (BBR) uncertainty and improved clock stability for systematic evaluations, the realization of a mid- to low-10−19 uncertainty Yb optical lattice clock is now more attainable than ever.
The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of 5.5×10(-19). Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now 1×10(-18). Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.
We describe recent experimental progress with the JILA Sr optical frequency standard, which has a systematic uncertainty at the 10-16fractional frequency level, currently limited by frequency shifts due to atomic interactions and room temperature blackbody radiation (BBR). We will discuss systematic measurements of collisional shifts and provide a complete theory to understand these interaction effects at the 10-17level. We will also discuss plans to interrogate atoms inside a cryogenic shield region to eliminate BBR shifts. We will present our recent successful efforts in improving the laser stability with the aim for the JILA Sr standard to reach the standard quantum measurement limit and achieve record levels of stability. Finally, a second Sr optical lattice clock has been constructed at JILA, and we will discuss the results of intercomparison experiments between the two standards.
Abstract We develop a method of synthetic frequency generation to construct an atomic clock with blackbody radiation (BBR) shift uncertainties below 10−19 at environmental conditions with a very low level of temperature control. The proposed method can be implemented for atoms and ions, which have two different clock transitions with frequencies ν 1 and ν 2 allowing to form a synthetic reference frequency ν syn = (ν 1 − ɛν 2)/(1 − ɛ), which is absent in the spectrum of the involved atoms or ions. Calibration coefficient ɛ can be chosen such that the temperature dependence of the BBR shift for the synthetic frequency ν syn has a local extremum at an arbitrary operating temperature T 0. This leads to a weak sensitivity of BBR shift with respect to the temperature variations near operating temperature T 0. As a specific example, the Yb+ ion is studied in detail, where the utilized optical clock transitions are of electric quadrupole (S → D) and octupole (S → F) type. In this case, temperature variations of ±7 K lead to BBR shift uncertainties of less than 10−19, showing the possibility to construct ultra-precise combined atomic clocks (including portable ones) without the use of cryogenic techniques.
Abstract Here we present a liquid nitrogen-cooled Ca+ optical clock with an overall systematic uncertainty of 3×10-18. In contrast with the room-temperature Ca+ optical clock that we have reported previously, the temperature of the blackbody radiation (BBR) shield in vacuum has been reduced to 82(5) K using liquid nitrogen. An ion trap with a lower heating rate and improved cooling lasers were also introduced. This allows cooling the ion temperature to the Doppler cooling limit during the clock operation, and the systematic uncertainty due to the ion’s secular (thermal) motion is reduced to < 1×10-18. The uncertainty due to the probe laser light shift and the servo error are also reduced to < 1×10-19 and 4×10-19 with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two was measured with a fractional statistical uncertainty of 7×10-18. The differential BBR shift was used to calculate the static differential polarizability, and it was found in excellent agreement with our previous measurement with a different method. This work suggests that the BBR shift of optical clocks can be well suppressed in a liquid nitrogen environment. This is advantageous because conventional liquid-helium cryogenic systems for optical clocks are more expensive and complicated. Moreover, the proposed system can be used to suppress the BBR shift significantly in other types of optical clocks such as Yb+, Sr+, Yb, Sr, etc.
A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock transition and, secondly, by interrogating the atoms in a cryogenic environment. Both approaches rely on transporting ultracold atoms over several cm within a probe cycle. We evaluate this approach of mechanically moving the optical lattice and conclude that it is feasible to transport the atoms over 50 mm within 300 ms. With this transport a dc Stark shift measurement will allow to reduce the contribution of the blackbody radiation to the fractional uncertainty below 2 * 10^-17 at room temperature by improving the shift coefficient known only from atomic structure calculations up to now. We propose a cryogenic environment at 77 K that will reduce this contribution to few parts in 10^-18.
Optical clocks have the potential to be 100 times more accurate than current best cesium atomic clocks within a fraction of the averaging time.This corresponds to a fractional uncertainty of the clock frequency on the level of 10 -18 and requires highaccuracy knowledge of systematic frequency shifts, such that they can be avoided or corrected for.In strontium optical lattice clocks an ensemble of ultracold strontium atoms is conned in an optical lattice, to allow for spectroscopy of the reference transition 5s 2 1 S 0 5s5p 3 P 0 in the Lamb-Dicke regime.The by far largest systematic frequency shift of the strontium clock transition is caused by its high sensitivity to blackbody radiation (BBR).The knowledge of the resulting frequency shift limited the achievable clock uncertainty to about 1 × 10 -16 .In this thesis for the rst time an experimental approach was followed, to determine the sensitivity of the strontium clock transition to blackbody radiation.At an environmental temperature of 300 K the resulting frequency shift corresponds to 2.277 8(23) Hz.The achieved uncertainty contributes with 5 × 10 -18 to the fractional systematic uncertainty of the clock frequency.The determination is based on a precision measurement of the dierence of static polarizabilities of the two clock states ∆α dc = α(5s5p 3 P 0 ) -α(5s 2 1 S 0 ) = 4.078 73(11) × 10 -39 Cm 2 /V.For this the dc Stark shift of the clock transition has been measured in the accurately known electric eld of a precision plate capacitor, which has been developed in this work.The attained static polarizability dierence ∆α dc corresponds to the rst term of a power series of the sensitivity to BBR.Higher orders are accumulated as dynamic part of the BBR shift.Which has been modelled using ∆α dc and experimental data for other atomic properties.To interrogate the ultracold atoms in the electric eld a novel transport technique has been developed, which uses the magic wavelength (813 nm) optical lattice to convey the atoms.For this, the interference pattern is translated together with the foci of the far-detuned lattice beams, by simultaneous translation of the lattice optics.In this way ultracold atoms have been transported within 250 ms over 5 cm, or several Rayleigh ranges respectively without signicant atom loss or heating.In the course of this work the rst frequency measurement with the strontium lattice clock of Physikalisch-Technischen Bundesanstalt (PTB) has been performed.The frequency of the 87 Sr clock transition was measured to be 429 228 004 229 872.9(5)Hz.The strontium lattice clock itself contributed with 1.5 × 10 -16 to the overall fractional uncertainty.Furthermore the thermal radiation eld in a cryogenic blackbody environment was modelled and a draft of a corresponding environment of the atoms was designed, which is suitable to be implemented in the strontium lattice clock of PTB.