Capacitively Coupled Hot-Electron Microbolometer as a Perspective IR and Sub-mm Wave Sensor

L. S. Kuzmin

Published Mar 1, 1998• 1 citation
OpenAlex

Abstract

normal metal strip at low temperatures (so called electron effect) to produce a large A novel concept of the normal-metal hotelectron bolometer using capacitive coupling of the absorber to antenna (NHEB-CC) has been proposed. The concept is based on the normal metal hot-electron microbolometer with Andreev mirrors (NHEB-A) using a SIN junction as a temperature sensor [1-3]. The NHEB-A technology brings a possibility to fabricate the sub-mm wave receiver for space applications with a noise equivalent power NEP about 3x1 0' 8 W/Hz at 100 mK. However, the Andreev mirrors could give certain frequency limitations for using this bolometer for higher frequencies with the energy quantum hf higher than the energy of a superconducting gap A. The NHEB-CC technology with capacitive coupling of the absorber to antenna avoids these problems. The effective high frequency coupling of the external signal in NHEB-CC is achieved by a low impedance of the coupling capacitances. At the same time, the capacitance gives reliable protection against escaping the hot electrons from the absorber. Usual tunnel junctions with proper thickness of the barrier can be used as capacitors. In such realization, we keep the main advantage of the NHEB technology very small thermal conductance between electrons and phonons due to small volume of an absorber (typical value of G is 2x10 W/K for T=100 mK) in combination with frequency independent protection of the absorber against thermal leak to the antenna.

Related papers

Capacitively Coupled Hot-Electron Nanobolometer with SIN Tunnel Junctions

L. S. Kuzmin, M. Yu. Fominsky, Alexei Kalabukhov +2 more

A capacitively coupled hot-electron nanobolometer (CC-HEB) is the simplest and most effective antenna-coupled bolometer. The bolometer consists of a small absorber connected to the superconducting antenna by tunnel junctions. The tunnel junctions used for high-frequency coupling also give perfect thermal isolation of hot electrons in the small volume of the absorber. The same tunnel junctions are used for temperature measurements and electron cooling. This bolometer does not suffer from the frequency limitations in the submillimeter range due to the high potential barrier of the tunnel junctions as does the microbolometer with Andreev mirrors (A-HEB), which is limited by the superconducting gap. Theoretical analyses show that the two-junction configuration more than doubles the sensitivity of the bolometer in current-biased mode compared to the single-junction configuration used for A-HEB. Another important advantage of CC-HEB is its simple two-layer technology for sample fabrication. Samples were fabricated with an absorber made of a bilayer of Cr and Al to match the impedance of the antenna. Electrodes were made of Al and tunnel junctions were formed over the Al oxide layer. The coupling capacitances of the tunnel junctions, C ≈ 20 fF, in combination with the inductance of the 10 μm absorber create a bandpass filter with a central frequency around 300 GHz. Bolometers are integrated with log-periodic and double-dipole planar antennas made of Au. The temperature response of bolometer structures was measured at temperatures down to 256 mK. In our experiment we observed dV/dT=1.3 mV/K, corresponding to responsivity S=0.2.109 V/W. For amplifier noise Vna=3nV/Hz1/2 at 1 kHz the estimated total noise equivalent power is NEP=1.5.10-17 W/Hz1/2. The intrinsic bolometer self noise Vnbol=0.5 nV/Hz1/2 corresponds to NEP=3.10-18 W/Hz1/2. For microwave evaluation of bolometer sensitivity we used a black body radiation source comprising a thin NiCr stimulator placed on the cold plate of cryostat in front of a CC-HEB attached to an extended hemisphere sapphire lens. This measurements were consistent with estimates based on the dc responsivity of the bolometer.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 1, 2003•6 citations

Optimal Cold-Electron Bolometer with a Superconductor-Insulator-Normal Tunnel Junction and an Andreev Contact

L. S. Kuzmin

A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.

•May 1, 2006•4 citations

Capacitively coupled hot-electron nanobolometer as far-infrared photon counter

Dragoş-Victor Anghel, L. S. Kuzmin

We show theoretically that hot-electron nanobolometers consisting of a small piece of normal metal, capacitively coupled to a superconducting antenna through a pair of normal metal–insulator–superconductor (NIS) tunnel junctions may be used as far-infrared photon counters. To make the device most effective at high counting rates, we suggest the use of the bolometer in the simplest configuration, when the NIS tunnel junctions are used as both an electron cooler and thermometer. The absorbtion of the photon in the normal metal produces a pulse in the electron temperature, which is measured by the NIS junctions. The counter may resolve photons up to 0.3–0.4 mm wavelength and has a typical re-equilibration time constant of about 20 ns.

arXiv:cond-mat/0212288•Applied Physics Letters•Jan 9, 2003•19 citations

A Resonant Cold-Electron Bolometer With a Kinetic Inductance Nanofilter

L. S. Kuzmin

A novel type of resonant cold-electron bolometer (RCEB) is proposed. In this sensor, the internal resonance is organized by the kinetic inductance of an ultrasmall NbN superconducting nanostrip and the capacitance of the nanoscale superconductor-insulator-normal (SIN) tunnel junction. The size of kinetic inductance is about 300 times smaller than the size of geometrical inductance of the same value. This reduction of size gives an opportunity to create nanofilters with a total size considerably smaller than the wavelength. This internal resonance acts as a bandpass filter (instead of external filters) with a bandwidth of 3%-50%, something needed for radioastronomy applications. The use of NbN as Andreev contact material against escaping hot quasiparticles provides a unique opportunity to create an optimal CEB with only one SIN junction and an Andreev SN contact for thermal protection, in contrast to a classical CEB with two SIN junctions. The problem of hot quasiparticles escaping over the Andreev barrier (Δ) for Al electrode is overcome here by creating a barrier higher than quantum energy Δ > hf to have working kinetic inductance. Replacing two SIN junctions by one junction, we could use this junction of half the area to keep the same capacitive coupling. Therefore, a single-junction RCEB would have four times less area of junctions (and volume of absorber) in comparison with a two-junction RCEB and should show better noise performance due to the proportionally decreased e-ph (electron-phonon) noise component. The RCEB can be effectively used to create multiband elements that are actual tasks in submillimeter astronomy due to the benefit that comes from its ability to use co-located data, and problems with the dramatic increase of the size of the focal plane.

IEEE Transactions on Terahertz Science and Technology•Mar 25, 2014•14 citations

Ultrasensitive Cold-Electron Bolometer

Ian Jasper Agulo

The Cold-Electron Bolometer (CEB) is an ultrasensitive device designed for the detection of cosmic microwave background radiation. The key to its sensitivity is the electron cooling of the absorber by the superconductor-insulator-normal metal (SIN) tunnel junction. At a voltage near and below the superconducting gap, the electrons in the absorber are cooled well below the phonon temperature of the normal metal. This translates to the enhanced sensitivity of the CEB. This thesis describes the work we have done on the optimization of electron cooling of the normal metal absorber, and our measurement of the sensitivity of the CEB. We have optimized the electron cooling of the absorber by SIN tunnel junctions. The best electron cooling was achieved when normal metal traps were added in proximity to the superconducting electrodes in addition to the advanced geometry of the superconducting electrodes. With these modifications, we have decreased the electron temperature by 198 mK. With just the advanced geometry, the electron temperature drop was 129 mK. With just a simple geometry, the drop in temperature was 56 mK.The noise equivalent power (NEP) of the CEB was also measured at 100 mK to be at the level of 10^-18 W/Hz^1/2 at 1 kHz. The NEP was obtained by measuring the noise of the CEB, and then dividing that by its power responsivity, dV/dP. The main limitation in our measurements was the noise component from the amplifier. Finally, we have made measurements on the temperature sensitivity of the SIN tunnel junctions. We have compared the sensitivity between single and ten SIN junctions in series and found that it increases proportionally to the number of junctions. The best temperature responsivity obtained for 10 junctions was approximately 15 μV/mK. Using such thermometer, we have been able to measure the temperature stability of the Oxford Instruments cryogenfree refrigerator to be plus/minus 250 μK for a period of 8 hours. The resolution of the thermometer was measured to be plus/minus100 μK, limited by the noise due to the amplifier. The current and future works are also discussed. These include: a CEB array designed to distribute the total power load, improving further the sensitivity; a one-thousand SIN tunnel junction series thermometer in order to realize and understand the fundamental limitation of such a device; a superconducting cold-electron bolometer (SCEB) for high background power loads; and different read-out systems including an on-chip quasiparticle amplifier (QPA).

•Aug 1, 2007•0 citations

Low-Noise Wide Bandwith, Hot Electron Bolometer Mixers for Submillimeter Wavelengths

William R. McGrath

Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.

•Sep 1, 1995•0 citations
normal metal strip at low temperatures (so called electron effect) to produce a large A novel concept of the normal-metal hotelectron bolometer using capacitive coupling of the absorber to antenna (NHEB-CC) has been proposed. The concept is based on the normal metal hot-electron microbolometer with Andreev mirrors (NHEB-A) using a SIN junction as a temperature sensor [1-3]. The NHEB-A technology brings a possibility to fabricate the sub-mm wave receiver for space applications with a noise equivalent power NEP about 3x1 0' 8 W/Hz at 100 mK. However, the Andreev mirrors could give certain frequency limitations for using this bolometer for higher frequencies with the energy quantum hf higher than the energy of a superconducting gap A. The NHEB-CC technology with capacitive coupling of the absorber to antenna avoids these problems. The effective high frequency coupling of the external signal in NHEB-CC is achieved by a low impedance of the coupling capacitances. At the same time, the capacitance gives reliable protection against escaping the hot electrons from the absorber. Usual tunnel junctions with proper thickness of the barrier can be used as capacitors. In such realization, we keep the main advantage of the NHEB technology very small thermal conductance between electrons and phonons due to small volume of an absorber (typical value of G is 2x10 W/K for T=100 mK) in combination with frequency independent protection of the absorber against thermal leak to the antenna.
A capacitively coupled hot-electron nanobolometer (CC-HEB) is the simplest and most effective antenna-coupled bolometer. The bolometer consists of a small absorber connected to the superconducting antenna by tunnel junctions. The tunnel junctions used for high-frequency coupling also give perfect thermal isolation of hot electrons in the small volume of the absorber. The same tunnel junctions are used for temperature measurements and electron cooling. This bolometer does not suffer from the frequency limitations in the submillimeter range due to the high potential barrier of the tunnel junctions as does the microbolometer with Andreev mirrors (A-HEB), which is limited by the superconducting gap. Theoretical analyses show that the two-junction configuration more than doubles the sensitivity of the bolometer in current-biased mode compared to the single-junction configuration used for A-HEB. Another important advantage of CC-HEB is its simple two-layer technology for sample fabrication. Samples were fabricated with an absorber made of a bilayer of Cr and Al to match the impedance of the antenna. Electrodes were made of Al and tunnel junctions were formed over the Al oxide layer. The coupling capacitances of the tunnel junctions, C ≈ 20 fF, in combination with the inductance of the 10 μm absorber create a bandpass filter with a central frequency around 300 GHz. Bolometers are integrated with log-periodic and double-dipole planar antennas made of Au. The temperature response of bolometer structures was measured at temperatures down to 256 mK. In our experiment we observed dV/dT=1.3 mV/K, corresponding to responsivity S=0.2.109 V/W. For amplifier noise Vna=3nV/Hz1/2 at 1 kHz the estimated total noise equivalent power is NEP=1.5.10-17 W/Hz1/2. The intrinsic bolometer self noise Vnbol=0.5 nV/Hz1/2 corresponds to NEP=3.10-18 W/Hz1/2. For microwave evaluation of bolometer sensitivity we used a black body radiation source comprising a thin NiCr stimulator placed on the cold plate of cryostat in front of a CC-HEB attached to an extended hemisphere sapphire lens. This measurements were consistent with estimates based on the dc responsivity of the bolometer.
A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.
We show theoretically that hot-electron nanobolometers consisting of a small piece of normal metal, capacitively coupled to a superconducting antenna through a pair of normal metal–insulator–superconductor (NIS) tunnel junctions may be used as far-infrared photon counters. To make the device most effective at high counting rates, we suggest the use of the bolometer in the simplest configuration, when the NIS tunnel junctions are used as both an electron cooler and thermometer. The absorbtion of the photon in the normal metal produces a pulse in the electron temperature, which is measured by the NIS junctions. The counter may resolve photons up to 0.3–0.4 mm wavelength and has a typical re-equilibration time constant of about 20 ns.
A novel type of resonant cold-electron bolometer (RCEB) is proposed. In this sensor, the internal resonance is organized by the kinetic inductance of an ultrasmall NbN superconducting nanostrip and the capacitance of the nanoscale superconductor-insulator-normal (SIN) tunnel junction. The size of kinetic inductance is about 300 times smaller than the size of geometrical inductance of the same value. This reduction of size gives an opportunity to create nanofilters with a total size considerably smaller than the wavelength. This internal resonance acts as a bandpass filter (instead of external filters) with a bandwidth of 3%-50%, something needed for radioastronomy applications. The use of NbN as Andreev contact material against escaping hot quasiparticles provides a unique opportunity to create an optimal CEB with only one SIN junction and an Andreev SN contact for thermal protection, in contrast to a classical CEB with two SIN junctions. The problem of hot quasiparticles escaping over the Andreev barrier (Δ) for Al electrode is overcome here by creating a barrier higher than quantum energy Δ > hf to have working kinetic inductance. Replacing two SIN junctions by one junction, we could use this junction of half the area to keep the same capacitive coupling. Therefore, a single-junction RCEB would have four times less area of junctions (and volume of absorber) in comparison with a two-junction RCEB and should show better noise performance due to the proportionally decreased e-ph (electron-phonon) noise component. The RCEB can be effectively used to create multiband elements that are actual tasks in submillimeter astronomy due to the benefit that comes from its ability to use co-located data, and problems with the dramatic increase of the size of the focal plane.
The Cold-Electron Bolometer (CEB) is an ultrasensitive device designed for the detection of cosmic microwave background radiation. The key to its sensitivity is the electron cooling of the absorber by the superconductor-insulator-normal metal (SIN) tunnel junction. At a voltage near and below the superconducting gap, the electrons in the absorber are cooled well below the phonon temperature of the normal metal. This translates to the enhanced sensitivity of the CEB. This thesis describes the work we have done on the optimization of electron cooling of the normal metal absorber, and our measurement of the sensitivity of the CEB. We have optimized the electron cooling of the absorber by SIN tunnel junctions. The best electron cooling was achieved when normal metal traps were added in proximity to the superconducting electrodes in addition to the advanced geometry of the superconducting electrodes. With these modifications, we have decreased the electron temperature by 198 mK. With just the advanced geometry, the electron temperature drop was 129 mK. With just a simple geometry, the drop in temperature was 56 mK.The noise equivalent power (NEP) of the CEB was also measured at 100 mK to be at the level of 10^-18 W/Hz^1/2 at 1 kHz. The NEP was obtained by measuring the noise of the CEB, and then dividing that by its power responsivity, dV/dP. The main limitation in our measurements was the noise component from the amplifier. Finally, we have made measurements on the temperature sensitivity of the SIN tunnel junctions. We have compared the sensitivity between single and ten SIN junctions in series and found that it increases proportionally to the number of junctions. The best temperature responsivity obtained for 10 junctions was approximately 15 μV/mK. Using such thermometer, we have been able to measure the temperature stability of the Oxford Instruments cryogenfree refrigerator to be plus/minus 250 μK for a period of 8 hours. The resolution of the thermometer was measured to be plus/minus100 μK, limited by the noise due to the amplifier. The current and future works are also discussed. These include: a CEB array designed to distribute the total power load, improving further the sensitivity; a one-thousand SIN tunnel junction series thermometer in order to realize and understand the fundamental limitation of such a device; a superconducting cold-electron bolometer (SCEB) for high background power loads; and different read-out systems including an on-chip quasiparticle amplifier (QPA).
Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.