Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEICE Technical Report; IEICE Tech. Rep.

Analysis of rf-SQUID ladder circuits with a single flux quantum signal for the transmission direction

祐也 辻, 武 小野美, 康治 中島

Published Jan 16, 2014• 0 citations
OpenAlex

Related papers

Analysis of Single Flux Quantum Logic Circuits using rf-SQUIDs

Hiroki Kodaka, Yoichi Okabe

Springer eBooks•Jan 1, 1996•0 citations

Single-flux-quantum pump based on a three-junction superconducting quantum interference device

Yoshinao Mizugaki, Jian Chen, Satoshi Nishikata +3 more

We demonstrate the operation of a single-flux-quantum (SFQ) pump that is electromagnetically dual to the single-electron pump. The circuit is composed of a three-junction superconducting quantum interference device with three control lines. By applying two phase-shifted rf signals magnetically, the SFQ-pump transfers one SFQ per one cycle of the rf signals even at zero- and negatively-biased condition. The circuit was fabricated using a Nb/AlOx/Nb Josephson junction technology. When we fed rf signals of 4.5 GHz, we observed a Shapiro step crossing the zero-current axis. Periodic dependence of voltage at the zero-biasing state upon dc offset flux was also confirmed.

Applied Physics Letters•Jun 17, 2002•6 citations

Flux-Quantum Transitions in a Three-Junction SQUID Controlled by Two RF Signals

Yoshinao Mizugaki

IEICE Transactions on Electronics•Mar 1, 2002•2 citations

Radio‐Frequency (rf) SQUID

Yi Zhang, Hui Dong, Hans‐Joachim Krause +2 more

To read out radio frequency (rf) superconducting quantum interference device (SQUID) signals, an rf resonance tank circuit is usually needed. Similar to dc SQUID systems, an rf SQUID system also detects a flux signal that can change slowly over time. In fact, rf SQUID readout electronics exhibit potential advantages over dc SQUID electronics in the direct readout scheme. A merit of rf SQUID systems is the need for just one coaxial cable to connect the readout electronics to the two-terminal element. In a complete magnetometric SQUID system, an input coil connects to a receiver loop (flux antenna) to pick up the measured signals and couples it to the SQUID via a mutual inductance. This chapter discusses the main differences between rf SQUIDs and dc SQUIDs. The significant difference between rf and DC SQUIDs is the occurrence of higher harmonic components in the flux-to-voltage characteristics.

Wiley eBooks•May 29, 2020•0 citations

SIGNAL AND NOISE CHARACTERISTICS OF RF-SQUIDS

V. I. Shnyrkov, Georgy M. Tsoi

WORLD SCIENTIFIC eBooks•Jun 1, 1992•6 citations

rf PUMPED SQUID WITH LARGE OUTPUT SIGNAL

G.S. Krivoy, V. A. Komashko

The dc SQUID had been presented for use in the rf SQUID instead of a weak link. The new device, referred to as “double SQUID”, possesses a large output signal (hundreds of microvolts) in operating in a hysteretic mode. For making an operating mode a double SQUID is coupled to a circuit traditional for rf SQUIDs containing a tank circuit and an rf current pumping generator. The magnetic flux being measured is recognized by the dc SQUID quantization loop which results in changing its critical current. As a result the height of the flat part of the tank circuit I–V characteristics coupled to a double SQUID is modulated. It is this modulation that is the SQUID output signal. The experimental investigations of the double SQUID showed the validity of the assumptions under consideration. Output signals up to 690 μV, noise spectral density ≈2×10−5ϕ0/ Hz 1/2 (ϕ0 is the flux quantum) and energy resolution ≈1.4×10−29 J/Hz have been obtained.

Modern Physics Letters B•Feb 28, 1991•5 citations
We demonstrate the operation of a single-flux-quantum (SFQ) pump that is electromagnetically dual to the single-electron pump. The circuit is composed of a three-junction superconducting quantum interference device with three control lines. By applying two phase-shifted rf signals magnetically, the SFQ-pump transfers one SFQ per one cycle of the rf signals even at zero- and negatively-biased condition. The circuit was fabricated using a Nb/AlOx/Nb Josephson junction technology. When we fed rf signals of 4.5 GHz, we observed a Shapiro step crossing the zero-current axis. Periodic dependence of voltage at the zero-biasing state upon dc offset flux was also confirmed.
To read out radio frequency (rf) superconducting quantum interference device (SQUID) signals, an rf resonance tank circuit is usually needed. Similar to dc SQUID systems, an rf SQUID system also detects a flux signal that can change slowly over time. In fact, rf SQUID readout electronics exhibit potential advantages over dc SQUID electronics in the direct readout scheme. A merit of rf SQUID systems is the need for just one coaxial cable to connect the readout electronics to the two-terminal element. In a complete magnetometric SQUID system, an input coil connects to a receiver loop (flux antenna) to pick up the measured signals and couples it to the SQUID via a mutual inductance. This chapter discusses the main differences between rf SQUIDs and dc SQUIDs. The significant difference between rf and DC SQUIDs is the occurrence of higher harmonic components in the flux-to-voltage characteristics.
The dc SQUID had been presented for use in the rf SQUID instead of a weak link. The new device, referred to as “double SQUID”, possesses a large output signal (hundreds of microvolts) in operating in a hysteretic mode. For making an operating mode a double SQUID is coupled to a circuit traditional for rf SQUIDs containing a tank circuit and an rf current pumping generator. The magnetic flux being measured is recognized by the dc SQUID quantization loop which results in changing its critical current. As a result the height of the flat part of the tank circuit I–V characteristics coupled to a double SQUID is modulated. It is this modulation that is the SQUID output signal. The experimental investigations of the double SQUID showed the validity of the assumptions under consideration. Output signals up to 690 μV, noise spectral density ≈2×10−5ϕ0/ Hz 1/2 (ϕ0 is the flux quantum) and energy resolution ≈1.4×10−29 J/Hz have been obtained.