Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Differential phase extraction in an atom gradiometer

Franck Pereira dos Santos

Published Jun 12, 2015• 0 citations
Publisher

Abstract

We present here a method for the extraction of the differential phase of an atom gradiometer that exploits the correlation of the vibration signal measured by an auxiliary classical sensor, such as a seismometer or an accelerometer. We show that sensitivities close to the quantum projection noise limit can be reached, even when the vibration noise induces phase fluctuations larger than $2\ensuremath{\pi}$. This method does not require the correlation between the atomic and classical signals to be perfect and allows for an exact determination of the differential phase, with no bias. It can also be applied to other configurations of differential interferometers, such as gyrometers, conjugate interferometers for the measurement of the fine-structure constant, or differential accelerometers for tests of the equivalence principle or detection of gravitational waves.

DOI
10.1103/physreva.91.063615

Related papers

Differential phase extraction in an atom gradiometer

Franck Pereira dos Santos

We present here a method for the extraction of the differential phase of an atom gradiometer that exploits the correlation of the vibration signal measured by an auxiliary classical sensor, such as a seismometer or an accelerometer. We show that sensitivities close to the quantum projection noise limit can be reached, even when the vibration noise induces phase fluctuations larger than 2$π$. This method doesn't require the correlation between the atomic and classical signals to be perfect and allows for an exact determination of the differential phase, with no bias. It can also be applied to other configurations of differential interferometers, such as for instance gyrometers, conjugate interferometers for the measurement of the fine structure constant, or differential accelerometers for tests of the equivalence principle or detection of gravitational waves.

arXiv:1506.01815•Jun 5, 2015•29 citations

Differential phase extraction in dual interferometers exploiting the correlation between classical and quantum sensors

Mehdi Langlois, Romain Caldani, Azer Trimeche +2 more

We perform the experimental demonstration of the method proposed earlier [F. P. Dos Santos, Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.

arXiv:1712.02071•Physical Review A•Nov 20, 2017•18 citations

Correlative methods for dual-species quantum tests of the weak equivalence principle

B. Barrett, Laura Antoni‐Micollier, Laure Chichet +5 more

Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.

arXiv:1503.08423•New Journal of Physics•Aug 27, 2015•64 citations

A prototype differential atom interferometer for fundamental physics

Charles F. A. Baynham, Richard Hobson, O. L. Buchmueller +97 more

Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .

arXiv:2504.09158•Nature•Jun 17, 2026•3 citations

Squeezing-enhanced accurate differential sensing under large phase noise

Robin Corgier, Marco Malitesta, Leonid A. Sidorenkov +6 more

Atom interferometers are reaching sensitivities fundamentally constrained by quantum fluctuations. A main challenge is to integrate entanglement into quantum sensing protocols to enhance precision while ensuring robustness against noise and systematics. Here, we theoretically investigate differential phase measurements with two atom interferometers using spin-squeezed states, accounting for common-mode phase noise spanning the full $2π$ range. We estimate the differential signal using model-free ellipse fitting, a robust method requiring no device calibration and resilient to additional noise sources. Our results show that spin-squeezing enables sensitivities below the standard quantum limit. Specifically, we identify optimal squeezed states that minimize the differential phase variance, scaling as $N^{-2/3}$, while eliminating bias inherent in ellipse fitting methods. We benchmark our protocol against the Cramér-Rao bound and compare it with hybrid methods that incorporate auxiliary classical sensors. Our findings provide a pathway to robust and high-precision atom interferometry, in realistic noisy environments and using readily available states and estimation methods.

arXiv:2501.18256•Jan 30, 2025•0 citations

Real-time compensation scheme for the accurate measurement of the differential phase in a dual-atom-interferometer gyroscope

Ze-Xi Lu, Zhan-Wei Yao, Honghui Chen +10 more

A dual-atom-interferometer gyroscope has high sensitivity for accurate rotation measurements because of its immunity to common-mode noise. However, a measurement error is induced as the common phase noise, e.g., vibration noise, increases. In this work, we demonstrated a real-time compensation (RTC) scheme to improve the accuracy of measurements of the differential phase in dual atom interferometers. The vibration noise was measured by two seismometers and its induced phase shift was fed back to the Raman lasers after this shift was calculated based on the sensitivity function of the atom interferometers. After the RTC module was applied, the interference signals obtained via the square modulation method were stabilized at their midfringe points, which caused the vibration-induced phase noise for each of the atom interferometers to decrease from 495 mrad to 165 mrad. The differential phase error obtained by the dual atom interferometers and two seismometers was reduced from 114.8 mrad to 49.6 mrad, which implies that the rotation measurement error was improved by a factor of 2.3. This work paves the way to accurately measuring the rotation signal and has promising applications in fields of precision measurements.

Physical Review A•Mar 10, 2025•2 citations
We present here a method for the extraction of the differential phase of an atom gradiometer that exploits the correlation of the vibration signal measured by an auxiliary classical sensor, such as a seismometer or an accelerometer. We show that sensitivities close to the quantum projection noise limit can be reached, even when the vibration noise induces phase fluctuations larger than 2\ensuremathπ2\ensuremath{\pi}2\ensuremathπ. This method does not require the correlation between the atomic and classical signals to be perfect and allows for an exact determination of the differential phase, with no bias. It can also be applied to other configurations of differential interferometers, such as gyrometers, conjugate interferometers for the measurement of the fine-structure constant, or differential accelerometers for tests of the equivalence principle or detection of gravitational waves.
We present here a method for the extraction of the differential phase of an atom gradiometer that exploits the correlation of the vibration signal measured by an auxiliary classical sensor, such as a seismometer or an accelerometer. We show that sensitivities close to the quantum projection noise limit can be reached, even when the vibration noise induces phase fluctuations larger than 2πππ. This method doesn't require the correlation between the atomic and classical signals to be perfect and allows for an exact determination of the differential phase, with no bias. It can also be applied to other configurations of differential interferometers, such as for instance gyrometers, conjugate interferometers for the measurement of the fine structure constant, or differential accelerometers for tests of the equivalence principle or detection of gravitational waves.
We perform the experimental demonstration of the method proposed earlier [F. P. Dos Santos, Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.
Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle (WEP). The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous 87 Rb and 39 K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the WEP with a sensitivity of 1.6 × 10 − 6 per measurement with an interrogation time of T = 10 ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.
Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .
Atom interferometers are reaching sensitivities fundamentally constrained by quantum fluctuations. A main challenge is to integrate entanglement into quantum sensing protocols to enhance precision while ensuring robustness against noise and systematics. Here, we theoretically investigate differential phase measurements with two atom interferometers using spin-squeezed states, accounting for common-mode phase noise spanning the full 2π2π2π range. We estimate the differential signal using model-free ellipse fitting, a robust method requiring no device calibration and resilient to additional noise sources. Our results show that spin-squeezing enables sensitivities below the standard quantum limit. Specifically, we identify optimal squeezed states that minimize the differential phase variance, scaling as N−2/3N^{-2/3}N−2/3, while eliminating bias inherent in ellipse fitting methods. We benchmark our protocol against the Cramér-Rao bound and compare it with hybrid methods that incorporate auxiliary classical sensors. Our findings provide a pathway to robust and high-precision atom interferometry, in realistic noisy environments and using readily available states and estimation methods.
A dual-atom-interferometer gyroscope has high sensitivity for accurate rotation measurements because of its immunity to common-mode noise. However, a measurement error is induced as the common phase noise, e.g., vibration noise, increases. In this work, we demonstrated a real-time compensation (RTC) scheme to improve the accuracy of measurements of the differential phase in dual atom interferometers. The vibration noise was measured by two seismometers and its induced phase shift was fed back to the Raman lasers after this shift was calculated based on the sensitivity function of the atom interferometers. After the RTC module was applied, the interference signals obtained via the square modulation method were stabilized at their midfringe points, which caused the vibration-induced phase noise for each of the atom interferometers to decrease from 495 mrad to 165 mrad. The differential phase error obtained by the dual atom interferometers and two seismometers was reduced from 114.8 mrad to 49.6 mrad, which implies that the rotation measurement error was improved by a factor of 2.3. This work paves the way to accurately measuring the rotation signal and has promising applications in fields of precision measurements.