Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Frequency shifts due to ultra-cold atom collisions

Kurt Gibble

Published Dec 1, 1993• 0 citations
OpenAlex

Abstract

It was anticipated that laser cooling of atoms to 2 {mu}K would improve the accuracy and resolution of laser and microwave spectroscopies by 2 to 3 orders of magnitude. In state-of-the-art room temperature Cs frequency standards, the 9 GHz ground state hyperfine transition is measured with a fractional accuracy of 3 x 10{sup {minus}14}. Since all of the formerly known systematic effects that limit the accuracy increase either linearly or as some high power of the atom`s velocity, the accuracy of a laser cooled Cs standard should be {approx} 10{sup {minus}16}. However, at {mu}K temperatures, the de Broglie wavelengths of the atoms are much larger than the scale of the interatomic potential so that collision cross sections can be as large as {lambda}{sub dB}{sup 2}/2{pi} {approx} 10{sup {minus}10} cm{sup 2}. Here, collisional frequency shifts in a laser-cooled Cs fountain are measured to be {minus}1.4 x 10{sup {minus}12} corresponding to a cross section of 0.5 x 10{sup {minus}10} cm{sup 2}. The author also expects to report experimental results showing a potentially strong magnetic field dependence of these cross sections for fields smaller than 0.2 G. The field of ultra-cold collisions will also be reviewed.

Related papers

An experimental study of the spin-exchange frequency shift in a laser-cooled cesium fountain frequency standard

S. Ghezali, Philippe Laurent, S.N. Lea +1 more

The spin-exchange frequency shift due to cold collisions between ground-state atoms appears to be the systematic effect which could limit the accuracy of a laser-cooled cesium fountain operating as a frequency standard. We have investigated this shift for atoms distributed among all the Zeeman substates of either the F = 4 or F = 3 hyperfine level of the 6 S 1/2 ground state of cesium and for the case where most of the atoms are prepared in F = 3, M F = 0 sublevel. The measured relative frequency shifts are respectively − 1.0·10 −21 , − 0.6·10 −21 and − 2.0·10 −21 (at/cm 3 ) −1 . These results agree with the measurements performed by Gibble and Chu at higher atom densities with atoms prepared in F = 3, M F = 0 sublevel. However, the precision of our frequency measurements is much better and is only limited at 2·10 −15 by the H-maser used as a reference oscillator. Finally, we show that the relative frequency shift due to cold collisions can be reduced to 10 −15 , while preserving a short-term frequency stability of about 10 −13 τ −1/2 .

Europhysics Letters (EPL)•Oct 1, 1996•88 citations

A Laser-cooled Cesium Fountain Frequency Standard and a Measurement of the Frequency Shift due to Ultra-cold Collisions

Kurt Gibble, Steven Kasapi, Steven Chu

In our Cs atomic fountain, we laser cooled and trapped 10(exp 10) Cs atoms in 0.4 s. By shifting the frequencies of the laser beams, the atoms were launched upwards at 2.5 m/s and a fraction of the atoms were optically pumped into the F=3 ground state. The unwanted atoms in the F=4 ground state were removed from the fountain with radiation pressure from a laser beam tuned to excite only those atoms. The Cs atoms in the F=3 state traveled ballistically upwards, were excited by the microwave cavity, and then returned back through the same cavity in the atomic fountain configuration.

•Jun 1, 1993•0 citations

Laser-cooled Cs frequency standard and a measurement of the frequency shift due to ultracold collisions

Kurt Gibble, Steven Chu

We demonstate a laser-cooled Cs fountain which can be used as a frequency standard. The fountain has been used to measure the frequency shift due to ultracold Cs-Cs collisions at temperatures below 2.8 \ensuremath{\mu}K. The measured shift is -12.9\ifmmode\pm\else\textpm\fi{}0.7 mHz for a density of (2.7\ifmmode\pm\else\textpm\fi{}1.5)\ifmmode\times\else\texttimes\fi{}${10}^{9}$ ${\mathrm{cm}}^{\mathrm{\ensuremath{-}}3}$ beginning with an even distribution (\ifmmode\pm\else\textpm\fi{}10%) among the F=3, ${\mathit{m}}_{\mathit{F}}$ states. For a fountain with 95% of the atoms in the ${\mathit{m}}_{\mathit{F}}$=0 states, we measure a frequency shift of -5.5\ifmmode\pm\else\textpm\fi{}0.5 mHz at a density of (3.5\ifmmode\pm\else\textpm\fi{}2.0)\ifmmode\times\else\texttimes\fi{}${10}^{8}$ ${\mathrm{cm}}^{\mathrm{\ensuremath{-}}3}$.

Physical Review Letters•Mar 22, 1993•263 citations

Laser-cooled Rb clocks

Chad Fertig, Ronald Legere, W. Suptitz +1 more

The authors present a preliminary measurement of the cold collision shift for /sup 87/Rb where they found the shift to be more than a factor of 10 smaller than that of a laser-cooled Cs clock. They also discuss calculations for /sup 85/Rb and demonstrate a juggling fountain. Juggling fountain clocks can achieve higher stability without requiring large improvements in the local oscillator. In this first Cs juggling experiment, the effects of collisions between juggled balls of atoms are studied.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•0 citations

Laser-cooled Rb clock

Chad Fertig, Jérémie Bouttier, Kurt Gibble

We demonstrate a prototype of a laser-cooled /sup 87/Rb fountain clock and measure the frequency shift due to cold collisions. The shift is fractionally 30 times smaller than that in a laser-cooled Cs clock. We observe a density dependent pulling by the microwave cavity and use it to cancel the collision shift. We have also demonstrated a juggling atomic fountain to study cold collisions and we discuss the importance of juggling for future fountain clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 8, 2002•8 citations

Advances in 133Cs Fountains: Control of the Cold Collision Shift and Observation of Feshbach Resonances

S. Bize

This paper describes the work performed at BNM‐SYRTE (Observatoire de Paris) over the past few years toward the improvement and the use of microwave frequency standards using laser‐cooled atoms. First, recent improvements of the 133Cs and 87Rb atomic fountains are described. An important advance is the achievement of a fractional frequency instability of 1.6 × 10−14τ−1/2 where τ is the measurement time in seconds, thanks to the routine use of a cryogenic sapphire oscillator as an ultra‐stable local frequency reference. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of 2 × 10−16 at 50 000 s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of 7 × 10−16, one order of magnitude below that of uncooled devices.

AIP conference proceedings•Jan 1, 2005•1 citation
It was anticipated that laser cooling of atoms to 2 {mu}K would improve the accuracy and resolution of laser and microwave spectroscopies by 2 to 3 orders of magnitude. In state-of-the-art room temperature Cs frequency standards, the 9 GHz ground state hyperfine transition is measured with a fractional accuracy of 3 x 10{sup {minus}14}. Since all of the formerly known systematic effects that limit the accuracy increase either linearly or as some high power of the atom`s velocity, the accuracy of a laser cooled Cs standard should be {approx} 10{sup {minus}16}. However, at {mu}K temperatures, the de Broglie wavelengths of the atoms are much larger than the scale of the interatomic potential so that collision cross sections can be as large as {lambda}{sub dB}{sup 2}/2{pi} {approx} 10{sup {minus}10} cm{sup 2}. Here, collisional frequency shifts in a laser-cooled Cs fountain are measured to be {minus}1.4 x 10{sup {minus}12} corresponding to a cross section of 0.5 x 10{sup {minus}10} cm{sup 2}. The author also expects to report experimental results showing a potentially strong magnetic field dependence of these cross sections for fields smaller than 0.2 G. The field of ultra-cold collisions will also be reviewed.
The spin-exchange frequency shift due to cold collisions between ground-state atoms appears to be the systematic effect which could limit the accuracy of a laser-cooled cesium fountain operating as a frequency standard. We have investigated this shift for atoms distributed among all the Zeeman substates of either the F = 4 or F = 3 hyperfine level of the 6 S 1/2 ground state of cesium and for the case where most of the atoms are prepared in F = 3, M F = 0 sublevel. The measured relative frequency shifts are respectively − 1.0·10 −21 , − 0.6·10 −21 and − 2.0·10 −21 (at/cm 3 ) −1 . These results agree with the measurements performed by Gibble and Chu at higher atom densities with atoms prepared in F = 3, M F = 0 sublevel. However, the precision of our frequency measurements is much better and is only limited at 2·10 −15 by the H-maser used as a reference oscillator. Finally, we show that the relative frequency shift due to cold collisions can be reduced to 10 −15 , while preserving a short-term frequency stability of about 10 −13 τ −1/2 .
In our Cs atomic fountain, we laser cooled and trapped 10(exp 10) Cs atoms in 0.4 s. By shifting the frequencies of the laser beams, the atoms were launched upwards at 2.5 m/s and a fraction of the atoms were optically pumped into the F=3 ground state. The unwanted atoms in the F=4 ground state were removed from the fountain with radiation pressure from a laser beam tuned to excite only those atoms. The Cs atoms in the F=3 state traveled ballistically upwards, were excited by the microwave cavity, and then returned back through the same cavity in the atomic fountain configuration.
We demonstate a laser-cooled Cs fountain which can be used as a frequency standard. The fountain has been used to measure the frequency shift due to ultracold Cs-Cs collisions at temperatures below 2.8 \ensuremath{\mu}K. The measured shift is -12.9\ifmmode\pm\else\textpm\fi{}0.7 mHz for a density of (2.7\ifmmode\pm\else\textpm\fi{}1.5)\ifmmode\times\else\texttimes\fi{}109{10}^{9}109 ${\mathrm{cm}}^{\mathrm{\ensuremath{-}}3}$ beginning with an even distribution (\ifmmode\pm\else\textpm\fi{}10%) among the F=3, mF{\mathit{m}}_{\mathit{F}}mF​ states. For a fountain with 95% of the atoms in the mF{\mathit{m}}_{\mathit{F}}mF​=0 states, we measure a frequency shift of -5.5\ifmmode\pm\else\textpm\fi{}0.5 mHz at a density of (3.5\ifmmode\pm\else\textpm\fi{}2.0)\ifmmode\times\else\texttimes\fi{}108{10}^{8}108 ${\mathrm{cm}}^{\mathrm{\ensuremath{-}}3}$.
This paper describes the work performed at BNM‐SYRTE (Observatoire de Paris) over the past few years toward the improvement and the use of microwave frequency standards using laser‐cooled atoms. First, recent improvements of the 133Cs and 87Rb atomic fountains are described. An important advance is the achievement of a fractional frequency instability of 1.6 × 10−14τ−1/2 where τ is the measurement time in seconds, thanks to the routine use of a cryogenic sapphire oscillator as an ultra‐stable local frequency reference. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of 2 × 10−16 at 50 000 s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of 7 × 10−16, one order of magnitude below that of uncooled devices.