Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Optimization of SQUID-based microwave parametric amplifiers for qubit readout

Chris Macklin, Rajamani Vijay, Eli M. Levenson-Falk, D. H. Slichter, Zlatko Minev, Irfan A. Siddiqi

Published Mar 21, 2011• 0 citations
OpenAlex

Related papers

Ultra-broadband microwave travelling-wave parametric amplifier for qubit readout

Chris Macklin, D. H. Slichter, Oded Yaakobi +6 more

Bulletin of the American Physical Society•Mar 18, 2013•0 citations

Qubit readout with a directional parametric amplifier

Katrina Sliwa, Baleegh Abdo, A. Narla +5 more

Bulletin of the American Physical Society•Mar 5, 2014•0 citations

On-chip Parametric Amplification in a Double Quantum Dots Circuit

Yong-Qiang Xu, Rui Wu, Si-Si Gu +8 more

In microwave-based quantum circuits, including double quantum dots (DQDs), superconducting qubits and spin qubits, parametric amplifiers are indispensable in achieving high-fidelity qubit readouts. Despite its importance, the application of parametric amplifiers is hampered by several challenges, such as high insertion losses, constrained tunability, and a pronounced vulnerability to magnetic fields. Here, we demonstrate an on-site single-atom parametric amplifier (SAPA) within a reconfigurable quantum circuit, which consists of a superconducting microwave cavity and two GaAs gate-defined DQDs. Leveraging the inherent nonlinearity of the DQD, a parametric gain exceeding 11 dB is achieved. This gain contributes to enhance the qubit readout, as evidenced by exceeding two times improvement in the signal-to-noise ratio (SNR) when employing the DQD-based amplifier for reading out another DQD. Our work not only presents a versatile experimental platform with enhanced readout capabilities in quantum computing, but also introduces alternative choices of parametric amplifiers for a variety of microwave-based quantum circuits.

quant-pharXiv:2603.18666•Science China Physics Mechanics and Astronomy•Mar 20, 2026•0 citations

A Fully Integrated CMOS Parametric Amplifier for Cryogenic Qubit Readout

Gabriel López-Pinar, C. Aldea, Santiago Celma +1 more

International Conference on Synthesis, Modeling, Analysis and Simulation Methods and Applications to Circuit Design•Jun 1, 2026•0 citations

Parametric amplifiers for simplified quantum readout

Nikita S. Klimovich

Nature Electronics•Nov 14, 2025•0 citations

Optimizing Pump Conditions of Parametric Amplifiers for Fast Multiplexed Readout of Superconducting Qubits

Jeongwon Kim, Wei Dai, Omrie Ovdat +3 more

Low-noise parametric amplifiers are widely used as the first-stage amplifier in qubit readout chains. The performance of parametric amplifiers depends sensitively on the choice of the pump condition. We propose a strategy for determining the pump condition that is tailored for fast multiplexed readout. Choosing the amplifier pump to maximize the signal-to-noise ratio (SNR) improvement at the readout frequency of the limiting qubit--the qubit that requires the longest readout time to reach a target SNR--minimizes the total multiplexed readout time. We demonstrate our pump calibration strategy experimentally on a five-qubit multiplexed readout chain with a traveling-wave parametric amplifier. Using our strategy, we reduce the multiplexed readout time by 320 ns compared to optimizing the average SNR improvement on all qubits, without degrading the target SNR for any qubit.

quant-pharXiv:2606.22080•Jun 23, 2026•0 citations
In microwave-based quantum circuits, including double quantum dots (DQDs), superconducting qubits and spin qubits, parametric amplifiers are indispensable in achieving high-fidelity qubit readouts. Despite its importance, the application of parametric amplifiers is hampered by several challenges, such as high insertion losses, constrained tunability, and a pronounced vulnerability to magnetic fields. Here, we demonstrate an on-site single-atom parametric amplifier (SAPA) within a reconfigurable quantum circuit, which consists of a superconducting microwave cavity and two GaAs gate-defined DQDs. Leveraging the inherent nonlinearity of the DQD, a parametric gain exceeding 11 dB is achieved. This gain contributes to enhance the qubit readout, as evidenced by exceeding two times improvement in the signal-to-noise ratio (SNR) when employing the DQD-based amplifier for reading out another DQD. Our work not only presents a versatile experimental platform with enhanced readout capabilities in quantum computing, but also introduces alternative choices of parametric amplifiers for a variety of microwave-based quantum circuits.
Low-noise parametric amplifiers are widely used as the first-stage amplifier in qubit readout chains. The performance of parametric amplifiers depends sensitively on the choice of the pump condition. We propose a strategy for determining the pump condition that is tailored for fast multiplexed readout. Choosing the amplifier pump to maximize the signal-to-noise ratio (SNR) improvement at the readout frequency of the limiting qubit--the qubit that requires the longest readout time to reach a target SNR--minimizes the total multiplexed readout time. We demonstrate our pump calibration strategy experimentally on a five-qubit multiplexed readout chain with a traveling-wave parametric amplifier. Using our strategy, we reduce the multiplexed readout time by 320 ns compared to optimizing the average SNR improvement on all qubits, without degrading the target SNR for any qubit.