Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Spectroscopy

Magnetometer Based on Single-Pass Generation in Atomic Alkali-Metal Vapors

Armen D. Sargsyan, David G. Sarkisyan

Published Nov 1, 2025• 2 citations
Publisher
DOI
10.1007/s10812-025-02000-1

Related papers

High-sensitivity multi-channel atomic magnetometer

Young Jin Kim

High-sensitivity multi-channel atomic magnetometers are described. Methods for operating multi-channel atomic magnetometers are also described. Moreover, devices incorporating a plurality of multi-channel atomic magnetometers are described. A multi-channel atomic magnetometer may use the spin-exchange relaxation-free (SERF) technique. A multi-channel atomic magnetometer may achieve multi-channel operation in a single module, reducing the cost of sensors. A multi-channel atomic magnetometer may be a 16-channel atomic magnetometer. A multi-channel atomic magnetometer may include a single large vapor cell including alkali-metal atoms and at least one buffer gas that restricts motion of atomic spins of the alkali-metal atoms, thereby making relatively small internal cell volumes act as a multiple independent local sensing channels. A multi-channel atomic magnetometer may include a broad pump beam that simultaneously polarizes all (or substantially all) of the alkali-metal atoms in each internal sensing volume of the vapor cell, and a broad probe beam that simultaneously measures magnetic fields at multiple sensing volumes with a photodiode array.

•Jan 23, 2023•0 citations

A compact fiberized alkali-vapor atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

Bulletin of the American Physical Society•Jun 5, 2012•0 citations

Developments in alkali -metal atomic magnetometry

Scott J. Seltzer

•Jan 1, 2008•307 citations

Effect of Spatial Homogeneity of Spin Polarization on Magnetic Field Response of an Optically Pumped Atomic Magnetometer Using a Hybrid Cell of K and Rb Atoms

Yosuke Ito, Hiroyuki Ohnishi, Keigo Kamada +1 more

We measured the spatial homogeneity of spin polarization, which is directly related to the sensitivity and magnetic linewidth of an optically pumped atomic magnetometer with a hybrid cell of K and Rb atoms. This was done by changing the position of the probe beam. Furthermore, for comparison, we also measured the sensitivity and magnetic linewidth of atomic magnetometers with single K and single Rb cells, and found that optically thick atoms were spin polarized homogeneously with the hybrid cell. Optically thin alkali metal vapor can be spin polarized homogeneously, and the spin polarization transfers to an optically thick alkali metal vapor. An atomic magnetometer with the hybrid cell was found to be more effective in realizing simultaneous signal measurements at different locations with the uniform sensitivity and magnetic linewidth.

IEEE Transactions on Magnetics•Oct 18, 2012•27 citations

Real-time measurement of pump beam polarization through the transmitted light intensity in a polarized alkali metal vapor cell

Lihong Duan, Lele Ma, Zeyi Hu +2 more

A laser beam with left-/right-handed circular polarization is generally used to create the oriented atomic spins for precision measurements in a spin-exchange relaxation-free (SERF) co-magnetometer. The fluctuation of laser polarization interferes with the spin polarization of alkali metal atoms, leading to the system performance degradation. Here, we report a method for real-time polarization state measurement by using the transmitted light intensity of the pump beam passing through the vapor cell. Based on the principle of circular dichroism, the optical absorption model of polarized alkali metal atoms is established. The simulation results of the transmittance of the pump laser with different polarization states through the alkali metal vapor cell are given and verified by experiments. The experimental results show that the circularly polarized beam has the weakest absorption, while the linearly polarized laser beam is absorbed the strongest. The achieved measurement accuracy stands at an impressive 98.83 %. This work provides a simple and easy-to-use way to measure the polarization state of the laser beam used in the vapor cell devices, particularly the microfabricated prototypes with limited space.

Optics Express•May 30, 2024•2 citations

Magnetometer and frequency standard based on coherently prepared thermal alkali atomic vapors

Affolderbach, Kemp, Knappe +3 more

Quantum Electronics and Laser Science Conference•Jan 1, 2000•0 citations
High-sensitivity multi-channel atomic magnetometers are described. Methods for operating multi-channel atomic magnetometers are also described. Moreover, devices incorporating a plurality of multi-channel atomic magnetometers are described. A multi-channel atomic magnetometer may use the spin-exchange relaxation-free (SERF) technique. A multi-channel atomic magnetometer may achieve multi-channel operation in a single module, reducing the cost of sensors. A multi-channel atomic magnetometer may be a 16-channel atomic magnetometer. A multi-channel atomic magnetometer may include a single large vapor cell including alkali-metal atoms and at least one buffer gas that restricts motion of atomic spins of the alkali-metal atoms, thereby making relatively small internal cell volumes act as a multiple independent local sensing channels. A multi-channel atomic magnetometer may include a broad pump beam that simultaneously polarizes all (or substantially all) of the alkali-metal atoms in each internal sensing volume of the vapor cell, and a broad probe beam that simultaneously measures magnetic fields at multiple sensing volumes with a photodiode array.
We measured the spatial homogeneity of spin polarization, which is directly related to the sensitivity and magnetic linewidth of an optically pumped atomic magnetometer with a hybrid cell of K and Rb atoms. This was done by changing the position of the probe beam. Furthermore, for comparison, we also measured the sensitivity and magnetic linewidth of atomic magnetometers with single K and single Rb cells, and found that optically thick atoms were spin polarized homogeneously with the hybrid cell. Optically thin alkali metal vapor can be spin polarized homogeneously, and the spin polarization transfers to an optically thick alkali metal vapor. An atomic magnetometer with the hybrid cell was found to be more effective in realizing simultaneous signal measurements at different locations with the uniform sensitivity and magnetic linewidth.
A laser beam with left-/right-handed circular polarization is generally used to create the oriented atomic spins for precision measurements in a spin-exchange relaxation-free (SERF) co-magnetometer. The fluctuation of laser polarization interferes with the spin polarization of alkali metal atoms, leading to the system performance degradation. Here, we report a method for real-time polarization state measurement by using the transmitted light intensity of the pump beam passing through the vapor cell. Based on the principle of circular dichroism, the optical absorption model of polarized alkali metal atoms is established. The simulation results of the transmittance of the pump laser with different polarization states through the alkali metal vapor cell are given and verified by experiments. The experimental results show that the circularly polarized beam has the weakest absorption, while the linearly polarized laser beam is absorbed the strongest. The achieved measurement accuracy stands at an impressive 98.83 %. This work provides a simple and easy-to-use way to measure the polarization state of the laser beam used in the vapor cell devices, particularly the microfabricated prototypes with limited space.