Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Magnetics

Effect of Spatial Homogeneity of Spin Polarization on Magnetic Field Response of an Optically Pumped Atomic Magnetometer Using a Hybrid Cell of K and Rb Atoms

Yosuke Ito, Hiroyuki Ohnishi, Keigo Kamada, Tetsuo Kobayashi

Published Oct 18, 2012• 27 citations
Publisher

Abstract

We measured the spatial homogeneity of spin polarization, which is directly related to the sensitivity and magnetic linewidth of an optically pumped atomic magnetometer with a hybrid cell of K and Rb atoms. This was done by changing the position of the probe beam. Furthermore, for comparison, we also measured the sensitivity and magnetic linewidth of atomic magnetometers with single K and single Rb cells, and found that optically thick atoms were spin polarized homogeneously with the hybrid cell. Optically thin alkali metal vapor can be spin polarized homogeneously, and the spin polarization transfers to an optically thick alkali metal vapor. An atomic magnetometer with the hybrid cell was found to be more effective in realizing simultaneous signal measurements at different locations with the uniform sensitivity and magnetic linewidth.

DOI
10.1109/tmag.2012.2199966

Related papers

Sensitivity Improvement of Spin-Exchange Relaxation Free Atomic Magnetometers by Hybrid Optical Pumping of Potassium and Rubidium

Yosuke Ito, Hiroyuki Ohnishi, Keigo Kamada +1 more

An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.

IEEE Transactions on Magnetics•Oct 1, 2011•53 citations

Density-ratio dependence of spin polarization and spatial homogeneity in hybrid Rb–Cs vapor cells

Ge Jin, Tao shi, Yuxin Chen +2 more

Abstract Hybrid spin-exchange optical pumping (hybrid SEOP) using multiple alkali-metal species is commonly employed to improve the spatial homogeneity of alkali spin polarization in atomic magnetometers and comagnetometers. We investigate the dependence of spin polarization and its spatial homogeneity on the alkali density ratio D r = [ Rb ] / [ Cs ] in Rb–Cs hybrid vapor cells. A series of cells with controlled D r were fabricated and characterized using absolute electron paramagnetic resonance polarimetry at multiple positions along the cell axis. The results show that the density ratio strongly influences both the magnitude and spatial uniformity of alkali polarization through the competition among optical pumping, spin exchange, and spin-destruction processes. An optimal density ratio is observed near D r ≈ 6.59 ± 0.47 , where the polarization reaches its maximum while maintaining high spatial homogeneity (end-to-end ratio ∼89% and RMS homogeneity > 95 % ). Under typical operating conditions, the optimal density ratio lies in the range D r ≈ 4 –10. These results clarify the role of the alkali density ratio in Rb–Cs hybrid SEOP and provide practical guidance for optimizing hybrid vapor cells used in precision atomic magnetometers and comagnetometers.

Journal of Physics D Applied Physics•Apr 21, 2026•1 citation

Ultrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell

Yintao Ma, Yao Chen, Mingzhi Yu +8 more

Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.

Microsystems & Nanoengineering•Aug 30, 2024•62 citations

Improvement of spin polarization spatial uniformity in optically pumped atomic magnetometers based on counter-propagating pump beams and atomic diffusion

Junpeng Zhao, Gang Liu, Jixi Lu +9 more

Abstract In an optically pumped alkali vapor cell with a high density of atoms, the attenuation of the pump light generates a spatially non-uniform distribution of the electronic spin polarization of alkali atoms, which is detrimental to biomagnetism applications of magnetometers as well as the hyperpolarization of noble gas atoms. Therefore, in this study, we propose a new scheme to generate a nearly uniform, unsaturated spin polarization region based on counter-propagating pump beams and atomic diffusion. A finite element method-based simulation is used to demonstrate the three-dimensional distribution of the spin polarization in a spherical cell. The effects of cell temperature and pump light power on the homogeneity of the spin polarization are studied. The distribution of spin polarization near the center of the cell is experimentally measured and a 1 cm uniform spin polarization region is achieved in the center of the cell. The uniformity of spin polarization in the center region of the cell increased by 50% compared with single beam pumping. The advantage of our proposed scheme is that it can generate an unsaturated uniform region of spin polarization in the center of a cell using a single species of alkali atoms.

Measurement Science and Technology•Nov 9, 2020•49 citations

Research on the influence of alkali polarization on an all-optical atomic spin magnetometer based on hybrid pumping potassium and rubidium

Hong Zhang, Sheng Zou, Xiyuan Chen +1 more

An all-optical atomic spin magnetometer using a hybrid cell of K and Rb atoms is demonstrated in this paper. Via deriving and solving the Bloch equations, we established the models for the polarization rate of Rb and the magnetometer’s output signal, respectively. In order to achieve the maximum sensitivity, we carried out research on the influence of the pump power on the polarization rate and magnetometer’s output signal. The magnetometer’s sensitivity was found to be proportional to the polarization rate of Rb, which was confined by the pump power. In a certain context, theoretical predictions indicated that the larger the pump power was, the higher magnetometer’s sensitivity that could be realized. However, the theoretical estimate deviated from the experimental results. An analysis of the errors between the actual value and the theoretical value showed that the different molar ratio between the two species of alkali-metal atoms was the primary reason causing the deviation. By comparing the experimental measurement result with simulation result, we found the difference in the molar ratio to be approximate 4 times. After various parameters had been optimized, a sensitivity of 18 fT/Hz 1/2 was achieved by analyzing the signal-to-noise ratio.

Journal of the Korean Physical Society•Apr 1, 2015•9 citations

Spin-exchange relaxation-free magnetometry using elliptically polarized light

Vishal Shah, Michael V. Romalis

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of $7\text{ }\text{fT}/\sqrt{\text{Hz}}$ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.

arXiv:0903.2447•Physical Review A•Jul 24, 2009•273 citations
We measured the spatial homogeneity of spin polarization, which is directly related to the sensitivity and magnetic linewidth of an optically pumped atomic magnetometer with a hybrid cell of K and Rb atoms. This was done by changing the position of the probe beam. Furthermore, for comparison, we also measured the sensitivity and magnetic linewidth of atomic magnetometers with single K and single Rb cells, and found that optically thick atoms were spin polarized homogeneously with the hybrid cell. Optically thin alkali metal vapor can be spin polarized homogeneously, and the spin polarization transfers to an optically thick alkali metal vapor. An atomic magnetometer with the hybrid cell was found to be more effective in realizing simultaneous signal measurements at different locations with the uniform sensitivity and magnetic linewidth.
An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.
Abstract Hybrid spin-exchange optical pumping (hybrid SEOP) using multiple alkali-metal species is commonly employed to improve the spatial homogeneity of alkali spin polarization in atomic magnetometers and comagnetometers. We investigate the dependence of spin polarization and its spatial homogeneity on the alkali density ratio D r = [ Rb ] / [ Cs ] in Rb–Cs hybrid vapor cells. A series of cells with controlled D r were fabricated and characterized using absolute electron paramagnetic resonance polarimetry at multiple positions along the cell axis. The results show that the density ratio strongly influences both the magnitude and spatial uniformity of alkali polarization through the competition among optical pumping, spin exchange, and spin-destruction processes. An optimal density ratio is observed near D r ≈ 6.59 ± 0.47 , where the polarization reaches its maximum while maintaining high spatial homogeneity (end-to-end ratio ∼89% and RMS homogeneity > 95 % ). Under typical operating conditions, the optimal density ratio lies in the range D r ≈ 4 –10. These results clarify the role of the alkali density ratio in Rb–Cs hybrid SEOP and provide practical guidance for optimizing hybrid vapor cells used in precision atomic magnetometers and comagnetometers.
Abstract The chip-scale hybrid optical pumping spin-exchange relaxation-free (SERF) atomic magnetometer with a single-beam arrangement has prominent applications in biomagnetic measurements because of its outstanding features, including ultrahigh sensitivity, an enhanced signal-to-noise ratio, homogeneous spin polarization and a much simpler optical configuration than other devices. In this work, a miniaturized single-beam hybrid optical pumping SERF atomic magnetometer based on a microfabricated atomic vapor cell is demonstrated. Although the optically thin Cs atoms are spin-polarized, the dense Rb atoms determine the experimental results. The enhanced signal strength and narrowed resonance linewidth are experimentally proven, which shows the superiority of the proposed magnetometer scheme. By using a differential detection scheme, we effectively suppress optical noise with an approximate five-fold improvement. Moreover, the cell temperature markedly affects the performance of the magnetometer. We systematically investigate the effects of temperature on the magnetometer parameters. The theoretical basis for these effects is explained in detail. The developed miniaturized magnetometer has an optimal magnetic sensitivity of 20 fT/Hz 1/2 . The presented work provides a foundation for the chip-scale integration of ultrahighly sensitive quantum magnetometers that can be used for forward-looking magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
Abstract In an optically pumped alkali vapor cell with a high density of atoms, the attenuation of the pump light generates a spatially non-uniform distribution of the electronic spin polarization of alkali atoms, which is detrimental to biomagnetism applications of magnetometers as well as the hyperpolarization of noble gas atoms. Therefore, in this study, we propose a new scheme to generate a nearly uniform, unsaturated spin polarization region based on counter-propagating pump beams and atomic diffusion. A finite element method-based simulation is used to demonstrate the three-dimensional distribution of the spin polarization in a spherical cell. The effects of cell temperature and pump light power on the homogeneity of the spin polarization are studied. The distribution of spin polarization near the center of the cell is experimentally measured and a 1 cm uniform spin polarization region is achieved in the center of the cell. The uniformity of spin polarization in the center region of the cell increased by 50% compared with single beam pumping. The advantage of our proposed scheme is that it can generate an unsaturated uniform region of spin polarization in the center of a cell using a single species of alkali atoms.
An all-optical atomic spin magnetometer using a hybrid cell of K and Rb atoms is demonstrated in this paper. Via deriving and solving the Bloch equations, we established the models for the polarization rate of Rb and the magnetometer’s output signal, respectively. In order to achieve the maximum sensitivity, we carried out research on the influence of the pump power on the polarization rate and magnetometer’s output signal. The magnetometer’s sensitivity was found to be proportional to the polarization rate of Rb, which was confined by the pump power. In a certain context, theoretical predictions indicated that the larger the pump power was, the higher magnetometer’s sensitivity that could be realized. However, the theoretical estimate deviated from the experimental results. An analysis of the errors between the actual value and the theoretical value showed that the different molar ratio between the two species of alkali-metal atoms was the primary reason causing the deviation. By comparing the experimental measurement result with simulation result, we found the difference in the molar ratio to be approximate 4 times. After various parameters had been optimized, a sensitivity of 18 fT/Hz 1/2 was achieved by analyzing the signal-to-noise ratio.
Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer using a single elliptically polarized off-resonant laser beam. Circular component of the light creates relatively uniform spin polarization while the linear component is used to measure optical rotation generated by the atoms. Modulation of the atomic spin direction with an oscillating magnetic field shifts the detected signal to high frequencies. Using a fiber-coupled distributed feedback laser, we achieve magnetic field sensitivity of 7 fT/Hz7\text{ }\text{fT}/\sqrt{\text{Hz}}7 fT/Hz​ with a miniature $5\ifmmode\times\else\texttimes\fi{}5\ifmmode\times\else\texttimes\fi{}5\text{ }\text{mm}\text{ }\text{Rb}$ vapor cell.