Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Squeezed vacuum states from PPLN waveguide chips

Hsin-Hung Wu, Jui-Yuan Hou, Li‐An Chu, Rui-Cheng Hong, Te-Hwei Suen, Chien-Ming Wu, Yen-Hung Chen, Ray‐Kuang Lee

Published Jan 1, 2025• 0 citations
Publisher

Abstract

We report the experimental generation and measurement of quantum squeezed light source from a PPMgO:LN ridge waveguide at 1550 nm, up to a maximum squeezing level of -3.1 dB directly recorded, which provides an important platform for the development of quantum integrated optical circuits.
DOI
10.1364/cleo_at.2025.jps200_153

Related papers

Degradation analyses on the squeezed vacuum states generated from the PPLN waveguide chip

Hsin-Hung Wu, Po-Hsun Chu, Tzu-Yu Huang +6 more

We report the generation of squeezed light at 1550 nm, as well as the corresponding degradation analyses, from a fiber-based periodically poled lithium niobate (PPLN) waveguide chip. As an optical parametric amplifier (OPA), the highest squeezing level reaches over -3.0 dB. The performance of this on-chip squeezer is analyzed with the help of machine-learning quantum state tomography, to estimate the optical loss and phase noise, as well as the purity of the generated squeezed states at different pump powers. For quantum integrated optical circuits, our results provides a systematic characterization on the quantum light sources in continues variables.

Conference on Lasers and Electro-Optics•Jan 1, 2026•0 citations

4-dB Quadrature Squeezing With Fiber-Coupled PPLN Ridge Waveguide Module

Naoto Takanashi, Takahiro Kashiwazaki, Takushi Kazama +4 more

We have developed an optical parametric amplification module for quadrature squeezing with input and output ports coupled with optical fibers for both fundamental and second harmonic. The module consists of a periodically poled LiNbO3ridge waveguide fabricated with dry etching, dichroic beamsplitters, lenses and four optical fiber pigtales. The high durability of the waveguide and the good separation of squeezed light from a pump beam by the dichroic beamsplitter enable us to inject intense continuous-wave pump light with the power of over 300 mW. We perform -4.0±0.1 dB of noise reduction for a vacuum state at 1553.3 nm by using a fiber-optics-based measurement setup, which consists of a fiber-optic beamsplitter and a homemade fiber-receptacle balanced detector. The intrinsic loss of the squeezed vacuum in the module is estimated to be 25%. Excluding the extrinsic loss of the measuremental system, the squeezing level in the output fiber of the module is estimated to be -5.7±0.1 dB. A modularized alignment-free fiber-coupled quadrature squeezer could help to realize quantum information processing with fiber optics.

arXiv:1906.09749•IEEE Journal of Quantum Electronics•Mar 23, 2020•26 citations

Detection of 3-dB continuous-wave squeezing at 1.55 {\mu}m from a fiber-coupled single-pass PPLN ridge waveguide

Naoto Takanashi, Takahiro Kashiwazaki, Takushi Kazama +4 more

We have developed an optical parametric amplification module for quadrature squeezing with input and output ports coupled with optical fibers for both fundamental and second harmonic. The module consists of a periodically poled LiNbO${}_{3}$ ridge waveguide fabricated with dry etching, dichroic beamsplitters, lenses and four optical fiber pigtales. The high durability of the waveguide and the good separation of squeezed light from a pump beam by the dichroic beamsplitter enable us to inject intense continuous-wave pump light with the power of over 300 mW. We perform $-$4.0${\pm}$0.1 dB of noise reduction for a vacuum state at 1553.3 nm by using a fiber-optics-based measurement setup, which consists of a fiber-optic beamsplitter and a homemade fiber-receptacle balanced detector. The intrinsic loss of the squeezed vacuum in the module is estimated to be 25%. Excluding the extrinsic loss of the measuremental system, the squeezing level in the output fiber of the module is estimated to be $-$5.7${\pm}$0.1 dB. A modularized alignment-free fiber-coupled quadrature squeezer could help to realize quantum information processing with fiber optics.

•Jun 24, 2019•0 citations

Generation of pulsed squeezed light at telecommunication wavelength using a high efficiency PPLN optical waveguide

M. Yoshimura, T. Sugaya, Takuya Hirano +4 more

In the present work, we report the generation of pulsed squeezed light at 1550 nm by parametric amplification in a low-optical-loss high-efficiency PPLN-WG of length 51 mm developed by NIMS/Waseda. We observed -1.7 dB of squeezing and +6.5 dB of anti-squeezing when the pump pulse energy was only 3nJ (peak power was 0.5 W). The results indicate that the waveguide is capable of generating more than 6 dB squeezing by improving optical losses by shortening the WG length, anti-reflecting coating on WG surfaces, and temporal shaping of the local oscillator, and more that 10 dB squeezing may be possible by using the state of-the-art high efficiency photodiodes.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•0 citations

Integrated waveguide sources of squeezed vacuum for gravitational wave detection and quantum metrology

Hamza Hasnaoui, M. Leonardi, J.-P. Zendri +2 more

Integrated optics is one of the most promising platforms for quantum technologies. Integrated nonlinear waveguides have been used for the generation of quantum states of light for several applications. Here we discuss a project for the generation of squeezed vacuum in periodically poled waveguides made on a lithium niobate substrate. This non-classical optical state has been used for enhancing high precision measurements in gravitational wave detectors. However, in this application bulk sources of squeezed vacuum states have been employed. Integrated optics can provide a more robust and reliable way for the generation of these states which have great potential not only for interferometric GW detectors, but also for other high-precision optical measurements as well as for quantum computing purposes.

Frontiers in Sensors•Dec 1, 2025•0 citations

Improved waveguide-based ultraviolet light generation and pulsed squeezing at 795 nm

Aki Torii, Kosuke Shibata, Yujiro Eto +1 more

We report on the waveguide-based generation of pulsed squeezed light at 795 nm, suitable for quantum enhanced measurements with rubidium atoms. Pulsed ultraviolet second harmonic light with a power of more than 400 mW is produced using a periodically poled LiNbO3 (PPLN) waveguide and is injected into another PPLN waveguide to generate quadrature squeezing. We find that the phase of the second harmonic pulse is shifted within a pulse, and we attribute the shift to heating due to blue-light induced infrared absorption (BLIIRA) from a comparison between the experiment and a numerical simulation. A squeezing level of −1.5(1) dB is observed in homodyne detection when we apply a linear phase shift to the local oscillator. The experiment and simulation imply that the squeezing level can be further improved by reducing BLIIRA.

Optics Express•Jun 28, 2022•2 citations
We report the generation of squeezed light at 1550 nm, as well as the corresponding degradation analyses, from a fiber-based periodically poled lithium niobate (PPLN) waveguide chip. As an optical parametric amplifier (OPA), the highest squeezing level reaches over -3.0 dB. The performance of this on-chip squeezer is analyzed with the help of machine-learning quantum state tomography, to estimate the optical loss and phase noise, as well as the purity of the generated squeezed states at different pump powers. For quantum integrated optical circuits, our results provides a systematic characterization on the quantum light sources in continues variables.
We have developed an optical parametric amplification module for quadrature squeezing with input and output ports coupled with optical fibers for both fundamental and second harmonic. The module consists of a periodically poled LiNbO3ridge waveguide fabricated with dry etching, dichroic beamsplitters, lenses and four optical fiber pigtales. The high durability of the waveguide and the good separation of squeezed light from a pump beam by the dichroic beamsplitter enable us to inject intense continuous-wave pump light with the power of over 300 mW. We perform -4.0±0.1 dB of noise reduction for a vacuum state at 1553.3 nm by using a fiber-optics-based measurement setup, which consists of a fiber-optic beamsplitter and a homemade fiber-receptacle balanced detector. The intrinsic loss of the squeezed vacuum in the module is estimated to be 25%. Excluding the extrinsic loss of the measuremental system, the squeezing level in the output fiber of the module is estimated to be -5.7±0.1 dB. A modularized alignment-free fiber-coupled quadrature squeezer could help to realize quantum information processing with fiber optics.
We have developed an optical parametric amplification module for quadrature squeezing with input and output ports coupled with optical fibers for both fundamental and second harmonic. The module consists of a periodically poled LiNbO3{}_{3}3​ ridge waveguide fabricated with dry etching, dichroic beamsplitters, lenses and four optical fiber pigtales. The high durability of the waveguide and the good separation of squeezed light from a pump beam by the dichroic beamsplitter enable us to inject intense continuous-wave pump light with the power of over 300 mW. We perform $-4.04.04.0{\pm}$0.1 dB of noise reduction for a vacuum state at 1553.3 nm by using a fiber-optics-based measurement setup, which consists of a fiber-optic beamsplitter and a homemade fiber-receptacle balanced detector. The intrinsic loss of the squeezed vacuum in the module is estimated to be 25%. Excluding the extrinsic loss of the measuremental system, the squeezing level in the output fiber of the module is estimated to be $-5.75.75.7{\pm}$0.1 dB. A modularized alignment-free fiber-coupled quadrature squeezer could help to realize quantum information processing with fiber optics.
In the present work, we report the generation of pulsed squeezed light at 1550 nm by parametric amplification in a low-optical-loss high-efficiency PPLN-WG of length 51 mm developed by NIMS/Waseda. We observed -1.7 dB of squeezing and +6.5 dB of anti-squeezing when the pump pulse energy was only 3nJ (peak power was 0.5 W). The results indicate that the waveguide is capable of generating more than 6 dB squeezing by improving optical losses by shortening the WG length, anti-reflecting coating on WG surfaces, and temporal shaping of the local oscillator, and more that 10 dB squeezing may be possible by using the state of-the-art high efficiency photodiodes.
Integrated optics is one of the most promising platforms for quantum technologies. Integrated nonlinear waveguides have been used for the generation of quantum states of light for several applications. Here we discuss a project for the generation of squeezed vacuum in periodically poled waveguides made on a lithium niobate substrate. This non-classical optical state has been used for enhancing high precision measurements in gravitational wave detectors. However, in this application bulk sources of squeezed vacuum states have been employed. Integrated optics can provide a more robust and reliable way for the generation of these states which have great potential not only for interferometric GW detectors, but also for other high-precision optical measurements as well as for quantum computing purposes.
We report on the waveguide-based generation of pulsed squeezed light at 795 nm, suitable for quantum enhanced measurements with rubidium atoms. Pulsed ultraviolet second harmonic light with a power of more than 400 mW is produced using a periodically poled LiNbO3 (PPLN) waveguide and is injected into another PPLN waveguide to generate quadrature squeezing. We find that the phase of the second harmonic pulse is shifted within a pulse, and we attribute the shift to heating due to blue-light induced infrared absorption (BLIIRA) from a comparison between the experiment and a numerical simulation. A squeezing level of −1.5(1) dB is observed in homodyne detection when we apply a linear phase shift to the local oscillator. The experiment and simulation imply that the squeezing level can be further improved by reducing BLIIRA.