Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Thermorefractive-Noise Quiet Point of Optical Parametric Oscillators

Yun Zhao, Karl J. McNulty, Michal F. Lipson, Alexander L. Gaeta

Published Jan 1, 2025• 0 citations
Publisher

Abstract

We demonstrate a new mechanism to suppress the thermorefractive-induced frequency noise in optical parametric oscillators. By operating at the quiet point we observe a 5× noise reduction in the phase noise of the signal-idler difference frequency.
DOI
10.1364/cleo_si.2025.ss120_5

Related papers

Phase Diffusion and Quantum Noise in the Optical Parametric Oscillator: A Semiclassical Approach

J.-Y. Courtois, A. D. Smith, Claude Fabre +1 more

We calculate by the semiclassical method the noise spectra of a non-degenerate optical parametric oscillator operating above threshold when taking into account two independent diffusion processes on the pump phase and on the signal-idler phase difference. We also show that the phase diffusion processes are important when calculating the quantum noise in an optical parametric oscillator for noise frequencies close to the beat frequency between the signal and idler modes.

Journal of Modern Optics•Jan 1, 1991•33 citations

Experimental investigation of amplitude and phase quantum correlations in a type II optical parametric oscillator above threshold: from nondegenerate to degenerate operation

Julien Laurat, Laurent Longchambon, Claude Fabre +1 more

We describe a stable type II optical parametric oscillator operated above threshold that provides 9.7 +/- 0.5 dB (89%) of quantum noise reduction on the intensity difference of the signal and idler modes. We also report the first experimental study, to our knowledge, by homodyne detection of the generated bright two-mode state in the case of frequency-degenerate operation obtained by the introduction of a birefringent plate inside an optical cavity.

arXiv:quant-ph/0412108•Optics Letters•May 15, 2005•81 citations

Observation of large quantum noise reduction using an optical parametric oscillator

Thierry Debuisschert, Serge Reynaud, A. Heidmann +2 more

The authors have observed a quantum noise reduction of 69% around 2 MHz on the intensity difference between the two beams generated by a non-degenerate optical parametric oscillator operating above threshold.

Quantum Optics Journal of the European Optical Society Part B•Sep 1, 1989•70 citations

Nonclassical intensity correlation from a type I phase-matched optical parametric oscillator

K. W. Leong, N. C. Wong, Jeffrey H. Shapiro

Signal and idler beams from a type I phase-matched nondegenerate optical parametric oscillator are separated by a Mach-Zehnder interferometer. Broadband nonclassical intensity correlation is observed, in agreement with a theory that includes pump noise. The maximum observed correlation, which occurs at 1.1 MHz, yields a noise level 2.8 dB below the shot noise.

Optics Letters•Oct 1, 1990•20 citations

Observation of Quantum Noise Reduction on Twin Laser Beams

A. Heidmann, R. J. Horowicz, Serge Reynaud +3 more

We have used a two-mode optical parametric oscillator operating above threshold to generate high-intensity twin beams which exhibit quantum correlations. The noise power measured on the intensity difference between two such beams is reduced by 30% below the shot-noise limit. Noise reduction is observed over a broad range of frequencies.

Physical Review Letters•Nov 30, 1987•635 citations

Squeezing Phase Diffusion

S. Cialdi, Edoardo Suerra, Stefano Olivares +2 more

We address the use of optical parametric oscillator (OPO) to counteract phase diffusion, and demonstrate phase-noise reduction for coherent signals traveling through a suitably tuned OPO. In particular, we theoretically and experimentally show that there is a threshold value on the phase noise, above which OPO can be exploited to "squeeze" phase noise. The threshold depends on the energy of the input coherent state, and on the relevant parameters of the OPO, i.e., gain and input-output and crystal loss rates.

arXiv:1905.13158•Physical Review Letters•Apr 23, 2020•12 citations
We address the use of optical parametric oscillator (OPO) to counteract phase diffusion, and demonstrate phase-noise reduction for coherent signals traveling through a suitably tuned OPO. In particular, we theoretically and experimentally show that there is a threshold value on the phase noise, above which OPO can be exploited to "squeeze" phase noise. The threshold depends on the energy of the input coherent state, and on the relevant parameters of the OPO, i.e., gain and input-output and crystal loss rates.