Characterization of Response Time of Superconducting NbN Hot Electron Bolometer Mixers

GuoAo Xie, Ruixuan Tang, Zhenlin Luo, Kangmin Zhou, Jiameng Wang, Wei Miao, Weng Zhang, Yuan Ren, Sheng‐Cai Shi

Published May 17, 2025• 0 citations
Publisher

Abstract

Response time of a Superconducting Hot Electron Bolometer (HEB) mixers is a critical parameter, and significantly affects the intermediate frequency (IF) gain bandwidth. In this study, we investigated the effects of temperature and bias voltage on the response time. Response time of superconducting niobium nitride (NbN) HEB mixers were measured by using the pumpprobe technique at temperatures of 5 K, 7 K, and 9 K with different bias voltages. The measured response time ranged from 50 to 80 ps and decreased with increasing temperature and bias voltage. This approach provides a more comprehensive understanding of the thermal transport mechanisms in superconducting HEB mixers, which can ultimately lead to improved performance and properties of the HEB mixers.

DOI
10.1109/icet64964.2025.11103222

Related papers

Investigation of the Performance of NbN Superconducting HEB Mixers of Different Critical Temperatures

Wei Miao, Wen Zhang, Kangmin Zhou +7 more

In this paper, we investigate the critical temperature dependence of the performance of niobium nitride superconducting hot electron bolometer (HEB) mixers. The input noise temperature and intermediate frequency (IF) noise bandwidth of superconducting HEB mixers of different critical temperatures Tc(between 6 and 12 K) are simulated with a hot spot model. Simulation results show that the mixer input noise temperature is the lowest at Tcapproximately equal to 7-9.5 K and the IF noise bandwidth increases with Tc. We also measure three superconducting HEB mixers of different critical temperatures (i.e., 7.5, 8.8, and 10.3 K) at 0.85 and 1.3 THz. An agreement between measurement and prediction is observed.

IEEE Transactions on Applied Superconductivity•Nov 21, 2016•8 citations

Characterization of a quasi-optical NbN superconducting HEB mixer

Ling Jiang, Wei Miao, Wen Zhang +10 more

In this paper, the performance of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer, cryogenically cooled by a close-cycled 4-K refrigerator, is thoroughly investigated at 300, 500, and 850 GHz. The lowest receiver noise temperatures measured at the respective three frequencies are 1400, 900, and 1350 K, which can go down to 659, 413, and 529 K, respectively, after correcting the loss and associated noise contribution of the quasi-optical system before the measured superconducting HEB mixer. The stability of the quasi-optical superconducting HEB mixer is also investigated here. The Allan variance time measured with a local oscillator pumping at 500 GHz and an IF bandwidth of 110 MHz is 1.5 s at the dc-bias voltage exhibiting the lowest noise temperature and increases to 2.5 s at a dc bias twice that voltage.

IEEE Transactions on Microwave Theory and Techniques•Jul 1, 2006•19 citations

Performance Investigation of a Quasi-Optical NbN HEB Mixer at Submillimeter Wavelength

Wei Miao, Y. Delorme, A. Féret +8 more

In this paper, the performance of a quasi-optical phonon-cooled NbN superconducting hot electron bolometer (HEB) mixer is thoroughly investigated. The variation of the receiver noise temperature and the conversion gain around 600 GHz with respect to DC bias voltage and LO pumping level has been measured. The lowest receiver noise temperature is 750 K and reduced to about 250 K after correcting the quasi-optical losses before the HEB mixer. We compared the measured results with the predictions according to one dimensional distributed hot spot model. A reasonable match between theoretical model and experiment is observed. In addition, the direct response of the HEB mixer (integrated with a log-periodic spiral antenna) is measured by using Fourier Transform Spectrometer (FTS). The stability of the receiver is also investigated by means of Allan variance time measurements performed with an intermediate frequency (IF) bandwidth of 40 MHz.

•Apr 1, 2009•0 citations

Bias Dependence of the Thermal Time Constant in Nb Superconducting Diffusion-Cooled HEB Mixers

D. Wilms Floet, J. R. Gao, T. M. Klapwijk +1 more

In this paper, we present an experimental study of the intermediate frequency bandwidth of a Nb diffusion-cooled hot-electron bolometer mixer for different bias voltages. The measurements show that the bandwidth increases with increasing voltage. Analysis of the data reveals that this effect is mainly caused

•May 1, 2000•0 citations

IF Gain Bandwidth of a Quasi-Optical NbN Superconducting HEB Mixer

Aiqin Cao, Ling Jiang, S. H. Chen +2 more

In this paper, the intermediate frequency (IF) gain bandwidth of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer is investigated at 500 GHz with an IF system incorporating with a frequency down-converting scheme which is able to sweep the IF signal in a frequency range of 0.3-4 GHz. The IF gain bandwidth of the device is measured to be 1.5 GHz when it is biased at a voltage of the minimum noise temperature, and becomes larger when the bias voltage increases.

International Conference on Microwave and Millimeter Wave Technology (ICMMT)•Apr 1, 2007•0 citations

Effect of NbN-Au contact pads on the performance of a superconducting NbN hot electron bolometer mixer

Xiaohui Guo, Wen Zhang, W. Miao +2 more

In this paper we study the effect of NbN-Au contact pads on the performance of a superconducting NbN hot electron bolometer (HEB) mixer. The receiver noise temperature (Trec) and IF noise bandwidth (BN) at a LO frequency of 1.3 THz are measured at different bath temperatures between 3.3 K and 8.5 K. The measured Trec and BN of the superconducting HEB mixer are nearly constant for Tbath/Tc less than 0.7, and increase quickly with the further increase of Tbath. Measurement results demonstrate that the NbN-Au contact pads in superconducting state nearly have no influence on Trec and Bn, but the contact pads in resistive state make Trec and BN increase quickly with Tbath, indicated by the slope change of current-voltage curves and IF output power peak.

IEEE International Workshop on Electromagnetics: Applications and Student Innovation Competition•May 1, 2016•0 citations
Response time of a Superconducting Hot Electron Bolometer (HEB) mixers is a critical parameter, and significantly affects the intermediate frequency (IF) gain bandwidth. In this study, we investigated the effects of temperature and bias voltage on the response time. Response time of superconducting niobium nitride (NbN) HEB mixers were measured by using the pumpprobe technique at temperatures of 5 K, 7 K, and 9 K with different bias voltages. The measured response time ranged from 50 to 80 ps and decreased with increasing temperature and bias voltage. This approach provides a more comprehensive understanding of the thermal transport mechanisms in superconducting HEB mixers, which can ultimately lead to improved performance and properties of the HEB mixers.
In this paper, we investigate the critical temperature dependence of the performance of niobium nitride superconducting hot electron bolometer (HEB) mixers. The input noise temperature and intermediate frequency (IF) noise bandwidth of superconducting HEB mixers of different critical temperatures Tc(between 6 and 12 K) are simulated with a hot spot model. Simulation results show that the mixer input noise temperature is the lowest at Tcapproximately equal to 7-9.5 K and the IF noise bandwidth increases with Tc. We also measure three superconducting HEB mixers of different critical temperatures (i.e., 7.5, 8.8, and 10.3 K) at 0.85 and 1.3 THz. An agreement between measurement and prediction is observed.
In this paper, the performance of a quasi-optical NbN superconducting hot-electron bolometer (HEB) mixer, cryogenically cooled by a close-cycled 4-K refrigerator, is thoroughly investigated at 300, 500, and 850 GHz. The lowest receiver noise temperatures measured at the respective three frequencies are 1400, 900, and 1350 K, which can go down to 659, 413, and 529 K, respectively, after correcting the loss and associated noise contribution of the quasi-optical system before the measured superconducting HEB mixer. The stability of the quasi-optical superconducting HEB mixer is also investigated here. The Allan variance time measured with a local oscillator pumping at 500 GHz and an IF bandwidth of 110 MHz is 1.5 s at the dc-bias voltage exhibiting the lowest noise temperature and increases to 2.5 s at a dc bias twice that voltage.
In this paper, the performance of a quasi-optical phonon-cooled NbN superconducting hot electron bolometer (HEB) mixer is thoroughly investigated. The variation of the receiver noise temperature and the conversion gain around 600 GHz with respect to DC bias voltage and LO pumping level has been measured. The lowest receiver noise temperature is 750 K and reduced to about 250 K after correcting the quasi-optical losses before the HEB mixer. We compared the measured results with the predictions according to one dimensional distributed hot spot model. A reasonable match between theoretical model and experiment is observed. In addition, the direct response of the HEB mixer (integrated with a log-periodic spiral antenna) is measured by using Fourier Transform Spectrometer (FTS). The stability of the receiver is also investigated by means of Allan variance time measurements performed with an intermediate frequency (IF) bandwidth of 40 MHz.
In this paper we study the effect of NbN-Au contact pads on the performance of a superconducting NbN hot electron bolometer (HEB) mixer. The receiver noise temperature (Trec) and IF noise bandwidth (BN) at a LO frequency of 1.3 THz are measured at different bath temperatures between 3.3 K and 8.5 K. The measured Trec and BN of the superconducting HEB mixer are nearly constant for Tbath/Tc less than 0.7, and increase quickly with the further increase of Tbath. Measurement results demonstrate that the NbN-Au contact pads in superconducting state nearly have no influence on Trec and Bn, but the contact pads in resistive state make Trec and BN increase quickly with Tbath, indicated by the slope change of current-voltage curves and IF output power peak.