Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Sensors

Measurement of Ultra-Low Frequency Vibrations Using an Atom Interferometer

Zenghan Ma, Wei Zhuang, Yang Zhao, Chuanjing Ruan, Qin Tian, Jiamin Yao, Jinyang Feng, Shuqing Wu, Fang Fang, Ling Wan

Published Jul 2, 2025• 0 citations
Publisher

Abstract

Measuring low-frequency and ultra-low-frequency vibration signals is of critical importance in fields such as structural mechanics, geological exploration, aerospace, precision machining, and biomedicine. Existing methods face limitations in achieving both ultra-low-frequency range and high precision. We present an ultra-low-frequency vibration measurement method based on the atom interferometer, capable of measuring vibration signals from 0.01 Hz to DC. The performance of measurement was experimentally demonstrated for vibrations between 0.007 Hz and 0.01 Hz, achieving a sensitivity of 1.1 μm/s2/Hz. Incorporating active vibration isolation can further enhance the measurement range, increasing the optimal sensitivity to 0.2 μm/s2/Hz.

DOI
10.3390/s25134136

Related papers

High data-rate atom interferometer for measuring acceleration

Hayden McGuinness, Akash V. Rakholia, Grant W. Biedermann

We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57μg/Hz to 36.7μg/Hz, respectively. Our method offers a dramatic increase in data rate and demonstrates a path to applications in highly dynamic environments. The performance of the device can largely be attributed to the high recapture efficiency of atoms from one interferometer measurement cycle to another.

arXiv:1109.4610•Applied Physics Letters•Jan 2, 2012•88 citations

Vibration compensation of an atom gravimeter

Aopeng Xu, Delong Kong, Zhijie Fu +2 more

For most atom interferometers, the vibration isolation unit is applied to reduce vibration noise. In our experiment, instead of isolation, the vibration signals are monitored, and combining with the sensitive function, the compensation phase shift for the atom interferometer is obtained. We focus on the correction over a wide spectrum rather than on "monochromatic" frequencies. The sensitivity of the atom gravimeter can be upgraded by a factor of more than two. Furthermore, we demonstrate that the atom interferometer can still produce a good measurement result without passive vibration isolation in extremely noisy environments by using vibration compensation.

Chinese Optics Letters•Jan 1, 2019•20 citations

Demonstration of an ultrahigh-sensitivity atom-interferometry absolute gravimeter

Zhong-Kun Hu, Bu-Liang Sun, Xiao‐Chun Duan +5 more

We present an ultrahigh-sensitivity gravimeter based on an ${}^{87}$Rb atom interferometer using stimulated Raman transitions. Compared with our previous work, a two-dimensional magneto-optical trap is added in the new gravimeter to increase the atom number and improve the detection signal-to-noise ratio, and a better optical phase-locked loop system is used to reduce the phase noise of Raman beams. Benefiting from these efforts and the excellent performance of the active vibration isolator, a short-term sensitivity of about 4.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$ ($1\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}\mathrm{Gal}=1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ $\text{m}/{\text{s}}^{2}$) is reached, which improves the sensitivity by a factor of 2 compared with the former best reported value. By a modulation experiment, we further indicate that the residual vibration noise contribution is about 1.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$, which implies a possible improvement over the present absolute gravity measurement level by about one order of magnitude. Moreover, we demonstrate a calibration experiment to directly evaluate the sub-$\ensuremath{\mu}$Gal resolution of our gravimeter.

Physical Review A•Oct 8, 2013•403 citations

Vibrational dephasing in matter-wave interferometers

A Rembold, G Schütz, R Röpke +4 more

Matter-wave interferometry is a highly sensitive tool to measure small perturbations in a quantum system.This property allows the creation of precision sensors for dephasing mechanisms such as mechanical vibrations.They are a challenge for phase measurements under perturbing conditions that cannot be perfectly decoupled from the interferometer, e.g.for mobile interferometric devices or vibrations with a broad frequency range.Here, we demonstrate a method based on second-order correlation theory in combination with Fourier analysis, to use an electron interferometer as a sensor that precisely characterizes the mechanical vibration spectrum of the interferometer.Using the high spatial and temporal single-particle resolution of a delay line detector, the data allows to reveal the original contrast and spatial periodicity of the interference pattern from 'washed-out' matter-wave interferograms that have been vibrationally disturbed in the frequency region between 100 and 1000 Hz.Other than with electromagnetic dephasing, due to excitations of higher harmonics and additional frequencies induced from the environment, the parts in the setup oscillate with frequencies that can be different to the applied ones.The developed numerical search algorithm is capable to determine those unknown oscillations and corresponding amplitudes.The technique can identify vibrational dephasing and decrease damping and shielding requirements in electron, ion, neutron, atom and molecule interferometers that generate a spatial fringe pattern on the detector plane.

arXiv:1608.04966•New Journal of Physics•Feb 15, 2017•9 citations

Hybrid quantum sensing using an optomechanical resonator coupled atom interferometer

Ashwin Rajagopalan

Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.

•Jan 1, 2026•0 citations

Decoherence-free neutron interferometry

Dmitry A. Pushin, M. Arif, David G. Cory

Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.

arXiv:1602.05938•Physical Review A•May 21, 2009•22 citations
Measuring low-frequency and ultra-low-frequency vibration signals is of critical importance in fields such as structural mechanics, geological exploration, aerospace, precision machining, and biomedicine. Existing methods face limitations in achieving both ultra-low-frequency range and high precision. We present an ultra-low-frequency vibration measurement method based on the atom interferometer, capable of measuring vibration signals from 0.01 Hz to DC. The performance of measurement was experimentally demonstrated for vibrations between 0.007 Hz and 0.01 Hz, achieving a sensitivity of 1.1 μm/s2/Hz. Incorporating active vibration isolation can further enhance the measurement range, increasing the optimal sensitivity to 0.2 μm/s2/Hz.
For most atom interferometers, the vibration isolation unit is applied to reduce vibration noise. In our experiment, instead of isolation, the vibration signals are monitored, and combining with the sensitive function, the compensation phase shift for the atom interferometer is obtained. We focus on the correction over a wide spectrum rather than on "monochromatic" frequencies. The sensitivity of the atom gravimeter can be upgraded by a factor of more than two. Furthermore, we demonstrate that the atom interferometer can still produce a good measurement result without passive vibration isolation in extremely noisy environments by using vibration compensation.
We present an ultrahigh-sensitivity gravimeter based on an 87{}^{87}87Rb atom interferometer using stimulated Raman transitions. Compared with our previous work, a two-dimensional magneto-optical trap is added in the new gravimeter to increase the atom number and improve the detection signal-to-noise ratio, and a better optical phase-locked loop system is used to reduce the phase noise of Raman beams. Benefiting from these efforts and the excellent performance of the active vibration isolator, a short-term sensitivity of about 4.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$ ($1\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}\mathrm{Gal}=1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ m/s2\text{m}/{\text{s}}^{2}m/s2) is reached, which improves the sensitivity by a factor of 2 compared with the former best reported value. By a modulation experiment, we further indicate that the residual vibration noise contribution is about 1.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$, which implies a possible improvement over the present absolute gravity measurement level by about one order of magnitude. Moreover, we demonstrate a calibration experiment to directly evaluate the sub-$\ensuremath{\mu}$Gal resolution of our gravimeter.
Matter-wave interferometry is a highly sensitive tool to measure small perturbations in a quantum system.This property allows the creation of precision sensors for dephasing mechanisms such as mechanical vibrations.They are a challenge for phase measurements under perturbing conditions that cannot be perfectly decoupled from the interferometer, e.g.for mobile interferometric devices or vibrations with a broad frequency range.Here, we demonstrate a method based on second-order correlation theory in combination with Fourier analysis, to use an electron interferometer as a sensor that precisely characterizes the mechanical vibration spectrum of the interferometer.Using the high spatial and temporal single-particle resolution of a delay line detector, the data allows to reveal the original contrast and spatial periodicity of the interference pattern from 'washed-out' matter-wave interferograms that have been vibrationally disturbed in the frequency region between 100 and 1000 Hz.Other than with electromagnetic dephasing, due to excitations of higher harmonics and additional frequencies induced from the environment, the parts in the setup oscillate with frequencies that can be different to the applied ones.The developed numerical search algorithm is capable to determine those unknown oscillations and corresponding amplitudes.The technique can identify vibrational dephasing and decrease damping and shielding requirements in electron, ion, neutron, atom and molecule interferometers that generate a spatial fringe pattern on the detector plane.
Quantum sensing using atom interferometry possesses immense potential for application in gravimetry, inertial navigation and for gravitational wave detection, apart from carrying out tests of fundamental physics. Atom interferometry can be used to perform absolute inertial measurements with unprecedented long term stability, unlike classical sensors which are prone to drift and incur calibration errors. However, atom interferometers seldom achieve their fundamental sensitivity due to the coupling of ambient vibrations. It is the dominant noise source that not only impairs performance but also affects its operability. Ideal compensation of the effects due to vibration noise using a versatile accelerometer, while concurrently enabling miniaturized atom interferometer setups has not been pioneered. Such a compact hybrid quantum sensor will enable reliable operation with an enhanced performance in field applications, paving the way for robust atom interferometry beyond laboratory conditions. A novel optomechanical resonator has been designed, developed and successfully hybridized with an atom interferometer to suppress the effects of vibration noise, and the results are presented in this thesis. The optomechanical resonator’s inertial test mass is simultaneously used to create a continuous intracavity optical lattice to sense its displacement, and a pulsed optical lattice to manipulate the atoms. For the first time, a broadband accelerometer is seamlessly hybridized with an atom interferometer via mechanical resonator mediated coupling of the optical lattices to measure acceleration. This enables elimination of vibration induced measurement ambiguity in our atom interferometer with a well defined mechanical transfer function. Vibration noise correlation is demonstrated up to our prototype atom interferometer’s most sensitive operating mode of T = 6 ms using double Bragg diffraction, ultimately limited by its technical noise. The optomechanical resonator measures acceleration with a sensitivity down to 1.1×10−6 ms−2/ √Hz corresponding to a displacement sensitivity of 8.6 × 10−15 m/ √Hz. Substantial 1/f noise suppression due to the developed optical readout scheme enables a measurement bandwidth spanning from sub-hertz frequencies up to several kilohertz. Multiple versions of the optomechanical resonator with different characteristics were developed and hybridized with our atom interferometer. This paves the way for developing tailored optomechanical resonators for specific inertial sensing applications.
Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.