Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Enhancing quantum imaging efficiency by quantum entanglement light source using a BiBO crystal

Kanako Yoshimura, Naru Yoneda, Osamu Matoba

Published May 23, 2025• 0 citations
Publisher

Abstract

Quantum imaging utilizing entangled photon pairs takes advantage of their strong quantum correlations to surpass the limitations of classical imaging techniques in terms of spatial resolution and signal-to-noise ratio. However, due to the low brightness of entangled photon sources, an enormous amount number of intensity images (\(\sim 10^7\)) is required for imaging, posing a challenge for practical implementation. In this study, we propose the use of a BiBO crystal for generating entangled photons to enhance the efficiency of quantum imaging. A BiBO crystal has large nonlinear optical coefficient, so it has been expected to serve as a high-brightness entangled photon source. However, a BiBO crystal has never been applied to quantum imaging because it's relatively recently discovered. Here, we investigate the potential of a BiBO crystal as a light source for high-efficiency quantum imaging by performing parallel intensity correlation measurements and implementing quantum image distillation as an example in comparison with the commonly used a BBO crystal. As a result, we achieved a tenfold reduction in measurement time of the conventional method and a significant improvement in imaging efficiency.

DOI
10.1364/opticaopen.29135192.v1

Related papers

Enhancing quantum imaging efficiency by BiBO crystal-based entangled light source

Kanako Yoshimura, Naru Yoneda, Osamu Matoba

Quantum imaging utilizing entangled photon pairs takes advantage of their strong quantum correlations to surpass the limitations of classical imaging techniques in terms of spatial resolution and signal-to-noise ratio. However, due to the low brightness of entangled photon sources, an enormous number of intensity images (∼107) is required for imaging in previous studies in order to acquire images with a sufficient signal-to-noise ratio, posing a challenge for practical implementation. A BiBO crystal, known for its large nonlinear optical coefficient, is considered a promising high-brightness entangled photon source. However, its performance has not been quantitatively evaluated in the context of quantum imaging systems, particularly regarding its impact on imaging performance. Here, we investigate the potential of a BiBO crystal as a light source for high-efficiency quantum imaging by performing parallel intensity correlation measurements and implementing quantum image distillation as an example in comparison with a commonly used BBO crystal. The results demonstrate that the use of the BiBO crystal enables more efficient quantum imaging compared to the conventional BBO crystal.

AIP Advances•Jun 1, 2026•3 citations

High-performance quantum imaging at telecom band with enhanced noise resilience

Xiaodong Fan, Zhonghua Ou, Yunru Fan +12 more

Quantum imaging utilizes the correlation of photons to enhance the security, covertness, and noise resilience of optical imaging. Despite recent advances, developing a quantum imaging system with long-distance and strong noise resilience remains challenging. Here, we present an experimental demonstration of high-performance quantum imaging at telecom band with enhanced noise resilience. We use a fiber-integrated quantum light source via cascaded second-order nonlinear processes to generate high-quality correlated/entangled photon pairs at telecom band and a fiber-coupled confocal optical system to effectively suppress the background noise and improve the collection efficiency of echo signal photons by optimizing its bandwidth and aperture. In our demonstration, the quantum imaging with correlated/entangled photon pairs or heralded single photons is achieved at a distance of 11 m under indoor illumination. When the detected environment noise is 33 dB stronger than the signal photons, corresponding to a coincidence-to-accidental coincidence ratio of 1.7 ± 0.1, an imaging contrast of 0.23 ± 0.09 is achieved, which is 46 times higher than single-photon imaging without correlation. The results will open venues for the development of practical quantum imaging techniques.

APL Photonics•Jul 1, 2025•7 citations

The biaxial nonlinear crystal BiB_3O_6 as a polarization entangled photon source using non-collinear type-II parametric down-conversion

A. Halevy, E. Megidish, L. Dovrat +3 more

We describe the full characterization of the biaxial nonlinear crystal BiB₃O₆ (BiBO) as a polarization entangled photon source using non-collinear type-II parametric down-conversion. We consider the relevant parameters for crystal design, such as cutting angles, polarization of the photons, effective nonlinearity, spatial and temporal walk-offs, crystal thickness and the effect of the pump laser bandwidth. Experimental results showing entanglement generation with high rates and a comparison to the well investigated β-BaB₂O₄ (BBO) crystal are presented as well. Changing the down-conversion crystal of a polarization entangled photon source from BBO to BiBO enhances the generation rate as if the pump power was increased by 2.5 times. Such an improvement is currently required for the generation of multiphoton entangled states.

arXiv:1106.5398•Optics Express•Oct 3, 2011•27 citations

Noise-resistant biologically correlated biphoton imaging based on a super-bunching light source

Xiangdong Li, LI Yuanyuan, Xinghui Liu +10 more

Correlation imaging based on entangled light sources offers potential benefits over classical single-photon imaging (SPI) in noisy environments, but also faces challenges such as low brightness, long integration times, and difficulty imaging biological organisms. Here, we propose noise-resistant biologically correlated biphoton imaging (CPI) based on a super-bunching light source, addressing the challenge of severe signal-to-noise ratio degradation in conventional SPI schemes. Our CPI, based on a super-bunching light source with high brightness, broadband spectrum (400–1100 nm), and strong quantum correlation (g 2 (0) ∼ 250), delivers high-performance, noise-resistant operation by extracting correlated photon pairs between the reference and signal paths. Experimental results show that under extreme noise conditions (noise-to-signal ratio up to 600), the structural profile in conventional SPI is entirely obscured by noise. In contrast, CPI still clearly resolves the target structure. Quantitative analysis further reveals that, as noise intensity increases, the imaging visibility of CPI can be enhanced by more than two orders of magnitude compared to SPI schemes. This study confirms the exceptional robustness and practical utility of super-bunching light-based correlated imaging in high-noise environments, offering an effective technical approach for high-quality biological observation in complex optical conditions.

Optics Express•Jun 9, 2026•0 citations

Microscopy using quantum sources of illumination

Miles John Padgett

We use entangled photons as the light source in a normal microscope. Using this quantum illumination improves both the resolution and noise rejection in the image. The resolution of any classical imaging system is limited by the diffraction created by the finite size of the imaging lens. By using a light source that emits pairs of entangled photons and carefully controlling a camera that is capable of detecting single photons it is possible to observe these photons arriving two-by-two. Applying camera analysis software to log only these two-by-two events one can form an image from the mid-point (bisector) of each of these pair events. The image formed from the sum of all these bisectors has an improved resolution that surpasses the classical limit. Another advantage of using a quantum illumination is that it allows the two-by-two events from entangled photon pairs to be distinguished from background (classical) light and sensor noise. When processed in this way the resulting image is free of camera noise and any background light may be eliminated. The use of a quantum illumination protocol such as that used here results in the elimination of background light and therefore allows the development of the optical equivalent of quantum radar – a quantum enhanced LIDAR scheme. Using quantum illumination, combined with commercially available cameras that are sensitive to single photons creates a new approach to super-resolution and low noise microscopy. Imaging through noise with quantum illumination, T Gregory, P-A Moreau, E Toninelli, and M J Padgett, Science Advances 6, eaay2652 (2020) Resolution-enhanced quantum imaging by centroid estimation of biphotons, E Toninelli, P-A Moreau, T Gregory, A Mihalyi, M Edgar, N Radwell, and M J Padgett, Optica 6, 347-353 (2019)

Photonics for Quantum (PfQ)•Aug 27, 2021•0 citations

Quantum super‐resolution imaging: a review and perspective

X. Yue, Hui Zhen Wu, Jizhou Wang +1 more

Quantum super-resolution imaging provides a nonlabeling method to surpass the diffraction limit of imaging systems. This technique relies on measurement of the second-order correlation function and usually employs spatially entangled photon sources. We introduce recent methods that achieve spatial resolution enhancement through quantum approaches, particularly the imaging techniques utilizing biphoton states. The fundamental mechanisms are discussed in detail to explain why biphoton states enable super-resolution. Additionally, we introduce multiple algorithms that extract the correlation function from the readings of two-dimensional detectors. Several cases are reviewed to evaluate the advantages and prospects of quantum imaging, along with a discussion of practical developments and potential applications.

Nanophotonics•Jan 16, 2025•20 citations
Quantum imaging utilizing entangled photon pairs takes advantage of their strong quantum correlations to surpass the limitations of classical imaging techniques in terms of spatial resolution and signal-to-noise ratio. However, due to the low brightness of entangled photon sources, an enormous amount number of intensity images ((\sim 10^7)) is required for imaging, posing a challenge for practical implementation. In this study, we propose the use of a BiBO crystal for generating entangled photons to enhance the efficiency of quantum imaging. A BiBO crystal has large nonlinear optical coefficient, so it has been expected to serve as a high-brightness entangled photon source. However, a BiBO crystal has never been applied to quantum imaging because it's relatively recently discovered. Here, we investigate the potential of a BiBO crystal as a light source for high-efficiency quantum imaging by performing parallel intensity correlation measurements and implementing quantum image distillation as an example in comparison with the commonly used a BBO crystal. As a result, we achieved a tenfold reduction in measurement time of the conventional method and a significant improvement in imaging efficiency.
Quantum imaging utilizing entangled photon pairs takes advantage of their strong quantum correlations to surpass the limitations of classical imaging techniques in terms of spatial resolution and signal-to-noise ratio. However, due to the low brightness of entangled photon sources, an enormous number of intensity images (∼107) is required for imaging in previous studies in order to acquire images with a sufficient signal-to-noise ratio, posing a challenge for practical implementation. A BiBO crystal, known for its large nonlinear optical coefficient, is considered a promising high-brightness entangled photon source. However, its performance has not been quantitatively evaluated in the context of quantum imaging systems, particularly regarding its impact on imaging performance. Here, we investigate the potential of a BiBO crystal as a light source for high-efficiency quantum imaging by performing parallel intensity correlation measurements and implementing quantum image distillation as an example in comparison with a commonly used BBO crystal. The results demonstrate that the use of the BiBO crystal enables more efficient quantum imaging compared to the conventional BBO crystal.
Quantum imaging utilizes the correlation of photons to enhance the security, covertness, and noise resilience of optical imaging. Despite recent advances, developing a quantum imaging system with long-distance and strong noise resilience remains challenging. Here, we present an experimental demonstration of high-performance quantum imaging at telecom band with enhanced noise resilience. We use a fiber-integrated quantum light source via cascaded second-order nonlinear processes to generate high-quality correlated/entangled photon pairs at telecom band and a fiber-coupled confocal optical system to effectively suppress the background noise and improve the collection efficiency of echo signal photons by optimizing its bandwidth and aperture. In our demonstration, the quantum imaging with correlated/entangled photon pairs or heralded single photons is achieved at a distance of 11 m under indoor illumination. When the detected environment noise is 33 dB stronger than the signal photons, corresponding to a coincidence-to-accidental coincidence ratio of 1.7 ± 0.1, an imaging contrast of 0.23 ± 0.09 is achieved, which is 46 times higher than single-photon imaging without correlation. The results will open venues for the development of practical quantum imaging techniques.
We describe the full characterization of the biaxial nonlinear crystal BiB₃O₆ (BiBO) as a polarization entangled photon source using non-collinear type-II parametric down-conversion. We consider the relevant parameters for crystal design, such as cutting angles, polarization of the photons, effective nonlinearity, spatial and temporal walk-offs, crystal thickness and the effect of the pump laser bandwidth. Experimental results showing entanglement generation with high rates and a comparison to the well investigated β-BaB₂O₄ (BBO) crystal are presented as well. Changing the down-conversion crystal of a polarization entangled photon source from BBO to BiBO enhances the generation rate as if the pump power was increased by 2.5 times. Such an improvement is currently required for the generation of multiphoton entangled states.
Correlation imaging based on entangled light sources offers potential benefits over classical single-photon imaging (SPI) in noisy environments, but also faces challenges such as low brightness, long integration times, and difficulty imaging biological organisms. Here, we propose noise-resistant biologically correlated biphoton imaging (CPI) based on a super-bunching light source, addressing the challenge of severe signal-to-noise ratio degradation in conventional SPI schemes. Our CPI, based on a super-bunching light source with high brightness, broadband spectrum (400–1100 nm), and strong quantum correlation (g 2 (0) ∼ 250), delivers high-performance, noise-resistant operation by extracting correlated photon pairs between the reference and signal paths. Experimental results show that under extreme noise conditions (noise-to-signal ratio up to 600), the structural profile in conventional SPI is entirely obscured by noise. In contrast, CPI still clearly resolves the target structure. Quantitative analysis further reveals that, as noise intensity increases, the imaging visibility of CPI can be enhanced by more than two orders of magnitude compared to SPI schemes. This study confirms the exceptional robustness and practical utility of super-bunching light-based correlated imaging in high-noise environments, offering an effective technical approach for high-quality biological observation in complex optical conditions.
We use entangled photons as the light source in a normal microscope. Using this quantum illumination improves both the resolution and noise rejection in the image. The resolution of any classical imaging system is limited by the diffraction created by the finite size of the imaging lens. By using a light source that emits pairs of entangled photons and carefully controlling a camera that is capable of detecting single photons it is possible to observe these photons arriving two-by-two. Applying camera analysis software to log only these two-by-two events one can form an image from the mid-point (bisector) of each of these pair events. The image formed from the sum of all these bisectors has an improved resolution that surpasses the classical limit. Another advantage of using a quantum illumination is that it allows the two-by-two events from entangled photon pairs to be distinguished from background (classical) light and sensor noise. When processed in this way the resulting image is free of camera noise and any background light may be eliminated. The use of a quantum illumination protocol such as that used here results in the elimination of background light and therefore allows the development of the optical equivalent of quantum radar – a quantum enhanced LIDAR scheme. Using quantum illumination, combined with commercially available cameras that are sensitive to single photons creates a new approach to super-resolution and low noise microscopy. Imaging through noise with quantum illumination, T Gregory, P-A Moreau, E Toninelli, and M J Padgett, Science Advances 6, eaay2652 (2020) Resolution-enhanced quantum imaging by centroid estimation of biphotons, E Toninelli, P-A Moreau, T Gregory, A Mihalyi, M Edgar, N Radwell, and M J Padgett, Optica 6, 347-353 (2019)
Quantum super-resolution imaging provides a nonlabeling method to surpass the diffraction limit of imaging systems. This technique relies on measurement of the second-order correlation function and usually employs spatially entangled photon sources. We introduce recent methods that achieve spatial resolution enhancement through quantum approaches, particularly the imaging techniques utilizing biphoton states. The fundamental mechanisms are discussed in detail to explain why biphoton states enable super-resolution. Additionally, we introduce multiple algorithms that extract the correlation function from the readings of two-dimensional detectors. Several cases are reviewed to evaluate the advantages and prospects of quantum imaging, along with a discussion of practical developments and potential applications.