Fiber Diamond-Based Quantum Sensor for High-Precision Current

Yuhao Li, Ziyang Zhu, Yu Lei, Feng Zhou, Junchang Huang, Qi Nie, Li Xia

Published Jan 1, 2025• 0 citations
Publisher
DOI
10.2139/ssrn.5201294

Related papers

Fiber diamond-based quantum sensor for high-precision current sensing

Yuhao Li, Haoliang Hu, Ziyang Zhu +5 more

Optics & Laser Technology•Jul 1, 2025•6 citations

Current status and prospects of diamond quantum sensors

睦子 波多野, Mutsuko Hatano

•Jun 1, 2022•0 citations

Current Status and Prospects of Diamond Quantum Sensors for Quantum-LEAP

睦子 波多野, Mutsuko Hatano

•Jun 1, 2024•0 citations

Simultaneous thermometry and magnetometry using a fiber-coupled quantum diamond sensor

Daisuke Nishitani, 春樹 岩塚, Haruki Iwatsuka +4 more

•Jan 1, 2021•0 citations

Quantum Sensing with Fiber-Coupled Diamond Emitters

Sean M. Blakley, Ilya V. Fedotov, Xinghua Liu +4 more

Bulletin of the American Physical Society•Mar 18, 2021•0 citations

Fiber-Based Quantum Sensor for High-Voltage Grid Current Measurement Using Integrated Diamond Quantum Sensor

Yaochen Zhu, Qihui Liu, Xiao Peng +8 more

In this report, we propose a quantum sensing architecture for high-voltage (HV) grid current measurement based on an integrated diamond quantum sensor (DQS). The DQS is installed in the HV line for non-invasive busbar current measurement. An optical fiber composite insulator (OFCI) is employed to deliver 532 nm laser for diamond excitation, 860 nm laser to energize sensing system and 830 nm light for communication between equipment on high-voltage and low-voltage side. The OFCI ensures robust insulation performance while facilitating high-precision, long-distance current measurements. Dual-channel microwave (MW) configuration implemented in the board-level measurement system tracks two resonant frequencies along the nitrogen-vacancy (NV) axis, effectively suppressing temperature drift. This quantum sensing scheme achieves a measurement range of up to 5000 A with an accuracy of 0.15%. This configuration presents a novel approach and reliable system for the practical application of quantum sensors in HV grid monitoring.

International Conference on Solid-State Sensors, Actuators and Microsystems•Jun 29, 2025•3 citations
In this report, we propose a quantum sensing architecture for high-voltage (HV) grid current measurement based on an integrated diamond quantum sensor (DQS). The DQS is installed in the HV line for non-invasive busbar current measurement. An optical fiber composite insulator (OFCI) is employed to deliver 532 nm laser for diamond excitation, 860 nm laser to energize sensing system and 830 nm light for communication between equipment on high-voltage and low-voltage side. The OFCI ensures robust insulation performance while facilitating high-precision, long-distance current measurements. Dual-channel microwave (MW) configuration implemented in the board-level measurement system tracks two resonant frequencies along the nitrogen-vacancy (NV) axis, effectively suppressing temperature drift. This quantum sensing scheme achieves a measurement range of up to 5000 A with an accuracy of 0.15%. This configuration presents a novel approach and reliable system for the practical application of quantum sensors in HV grid monitoring.