Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Effects and Measurement Techniques in Biology and Biophotonics

Nonlinear quantum bioimaging with bright squeezed light

Alex Terrasson, Nicolas P. Mauranyapin, Catxere A. Casacio, Joel Q. Grim, Kai Barnscheidt, Boris Hage, Michael A. Taylor, Warwick P. Bowen

Published Mar 21, 2025• 0 citations
Publisher
DOI
10.1117/12.3042808

Related papers

Quantum Statistics of Bright Squeezed Light and Squeezed Vacuum

Gerd Breitenbach, Stephan Schiller, J. Mlynek

European Quantum Electronics Conference (EQEC)•Jan 1, 1996•0 citations

Bright squeezed light via second harmonic generation in a whispering-gallery mode resonator

Matthew T. Simons, Irina V. Novikova

We investigate the conditions necessary for bright squeezed light generation through second harmonic generation inside a crystalline whispering-gallery mode resonator. We show that the variance of a coherent mode can be reduced by a factor of 9 due to low loss through a nonlinear medium. This results in a one-step process that can generate effcient bright squeeze light at a desired wavelength.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 22, 2013•1 citation

Nonlinear microscopy with squeezed light

Alex Terrasson

•Mar 22, 2024•0 citations

Bright Pulsed Squeezed Light for Quantum-Enhanced Precision Microscopy

Alex Terrasson, Lars Madsen, Joel Grim +1 more

Squeezed states of light enable enhanced measurement precision by reducing noise below the standard quantum limit. A key application of squeezed light is nonlinear microscopy, where state-of-the-art performance is limited by photodamage and quantum-limited noise. Such microscopes require bright, pulsed light for optimal operation, yet generating and detecting bright pulsed squeezing at high levels remains challenging. In this work, we present an efficient technique to generate high levels of bright picosecond pulsed squeezed light using a $χ^2$ optical parametric amplification process in a waveguide. We measure $-3.2~\mathrm{dB}$ of bright squeezing with optical power compatible with nonlinear microscopy, as well as $-3.6~\mathrm{dB}$ of vacuum squeezing. Corrected for losses, these squeezing levels correspond to $-15.4^{+2.7}_{-8.7}~\mathrm{dB}$ of squeezing generated in the waveguide. The measured level of bright amplitude pulsed squeezing is to our knowledge the highest reported to date, and will contribute to the broader adoption of quantum-enhanced nonlinear microscopy in biological studies.

quant-pharXiv:2601.15565•Jan 23, 2026•0 citations

Squeezed Light Tuning Of Quantum Images

John Jeffers, Gian‐Luca Oppo

European Quantum Electronics Conference (EQEC)•Aug 24, 2005•0 citations

Adapting quantum imaging for live bioimaging

Duncan P. Ryan, Jim Werner, Raymond Newell +6 more

High-Throughput Biophotonics: Imaging, Spectroscopy, and Beyond•Mar 5, 2026•0 citations
Squeezed states of light enable enhanced measurement precision by reducing noise below the standard quantum limit. A key application of squeezed light is nonlinear microscopy, where state-of-the-art performance is limited by photodamage and quantum-limited noise. Such microscopes require bright, pulsed light for optimal operation, yet generating and detecting bright pulsed squeezing at high levels remains challenging. In this work, we present an efficient technique to generate high levels of bright picosecond pulsed squeezed light using a χ2χ^2χ2 optical parametric amplification process in a waveguide. We measure −3.2 dB-3.2~\mathrm{dB}−3.2 dB of bright squeezing with optical power compatible with nonlinear microscopy, as well as −3.6 dB-3.6~\mathrm{dB}−3.6 dB of vacuum squeezing. Corrected for losses, these squeezing levels correspond to −15.4−8.7+2.7 dB-15.4^{+2.7}_{-8.7}~\mathrm{dB}−15.4−8.7+2.7​ dB of squeezing generated in the waveguide. The measured level of bright amplitude pulsed squeezing is to our knowledge the highest reported to date, and will contribute to the broader adoption of quantum-enhanced nonlinear microscopy in biological studies.