Abstract Weak values are found to play an important role in the study of many fundamental concepts of quantum mechanics. We present a method to simultaneously extract the imaginary part of the weak value of both path operators in a two-path Mach–Zehnder neutron interferometer using time-dependent phases. The measurement does not require spin manipulation, e.g. spin rotation and analysis. The methodology can be extended to an arbitrary number of paths and the working principles are transferable to any other kind of interferometer experiment in which alike time-dependent phases are feasible. Furthermore, we demonstrate a relation among components of path weak values relative to different post-selected states. This relation allows the additional extraction of the real part of both path weak values using the same setup, assuming the relative phase between the states after the different post-selections to be known.
Abstract Weak values are found to play an important role in the study of many fundamental concepts of quantum mechanics. We present a method to simultaneously extract the imaginary part of the weak value of both path operators in a two-path Mach–Zehnder neutron interferometer using time-dependent phases. The measurement does not require spin manipulation, e.g. spin rotation and analysis. The methodology can be extended to an arbitrary number of paths and the working principles are transferable to any other kind of interferometer experiment in which alike time-dependent phases are feasible. Furthermore, we demonstrate a relation among components of path weak values relative to different post-selected states. This relation allows the additional extraction of the real part of both path weak values using the same setup, assuming the relative phase between the states after the different post-selections to be known.
The statistical properties of the detection events constituting the interference fringes at the output of an interferometer are well-known. Nevertheless, there is still no unified view of what is happening to a quantum system inside an interferometer. Strong measurements of path operators destroy the interference effect. In weak measurements, an observable is weakly coupled to a pointer system and the resulting weak values quantify the observable by minimally disturbing the system. Previous which-way experiments with weak measurements could extract either the real or imaginary part of a single weak value with each ensemble. Here, we present the simultaneous full complex quantification of two path weak values with a single ensemble in a Mach-Zehnder neutron interferometer. Magnetic fields, oscillating with different frequencies, change the energy state in each interferometer path. The time-dependent phase between the energy states distinctly marks each path. The resulting beating intensity modulation at the interferometer output gives both path weak values. For the present experiment, the weak values' absolute value and phase directly describe the observed amplitude and phase of the intensity modulation.
Weak values provide a powerful framework for characterizing quantum systems. Their experimental extraction conventionally relies on weak conditioned von Neumann measurements, involving weak interactions and meter states that increase experimental complexity and often limit measurement efficiency. Here we introduce a method to fully characterize path weak-values in a generalized Mach-Zehnder interferometer employing neither meter states nor weak interactions. We experimentally demonstrate the technique in matter-wave interferometry. We identify anomalous weak values and, equivalently, negative quasiprobability distributions, which reflect the nonclassical behavior of the quantum system. The approach relies uniquely on intensity measurements at the output ports of the interferometer combined with controlled relative phase shifts between the paths. The absence of meter states enables considerable simplification of the setup and shorter measurement times, while preserving full access to weak values with comparable or increased accuracy. The scheme is directly applicable to a broad class of experiments involving two-level quantum systems.
Weak values, introduced more than 25 years ago, underwent a metamorphosis from a theoretical curiosity to a powerful resource in photonics for exploring foundations of quantum mechanics, as well as a practical laboratory tool. Due to the tiny coherence volume of particles used in matter-wave optics, a straightforward implementation of weak measurements is not feasible. We have overcome this hurdle by developing a method to weakly measure a massive particle's spin component. A neutron optical approach is realized by utilizing neutron interferometry, where the neutron's spin is coupled weakly to its spatial degree of freedom. Here, we present how one can fully characterize the weak value of the Pauli spin operator ${\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{\ensuremath{\sigma}}}_{z}$ of neutrons by extracting its real and imaginary components, as well as its modulus. The results show good agreement with theoretical predictions and demonstrate that the (spin) weak value is actually accessible for a purely quantum system of massive particles.
The weak value, the average result of a weak measurement, has proven useful for probing quantum and classical systems. Examples include amplifying small signals, investigating quantum paradoxes, and elucidating fundamental quantum phenomena such as geometric phase. A key characteristic of the weak value is that it can be complex, in contrast to a standard expectation value. However, typically only either the real or imaginary component of the weak value is determined in a given experimental setup. Weak measurements can be used to, in a sense, simultaneously measure noncommuting observables. This principle was used in the direct measurement of the quantum wave function. However, the wave function's real and imaginary components, given by a weak value, are determined in different setups or on separate ensembles of systems, putting the procedure's directness in question. To address these issues, we introduce and experimentally demonstrate a general method to simultaneously read out both components of the weak value in a single experimental apparatus. In particular, we directly measure the polarization state of an ensemble of photons using weak measurement. With our method, each photon contributes to both the real and imaginary parts of the weak-value average. On a fundamental level, this suggests that the full complex weak value is a characteristic of each photon measured.
Weak values have been shown to be helpful especially when considering them as the outcomes of weak measurements. In this paper we show that, in principle, the real and imaginary parts of the weak value of any operator may be elucidated from expectation values of suitably defined density, flux, and Hermitian commutator operators. Expectation values are the outcomes of strong (projective) measurements, implying that weak values are general properties of operators in association with pre- and postselection and they need not be preferentially associated with weak measurements. They should be considered as an important measurable property which provides added information compared with the ``standard'' diagonal expectation value of an operator. As the first specific example we consider the determination of the real and imaginary parts of the weak value of the momentum operator employing projective time-of-flight experiments. Then the results are analyzed from the point of view of Bohmian mechanics. Finally, we consider recent neutron interferometry experiments used to determine the weak values of the neutron spin.
Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).