Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Enhancement in sensitivity of coherent anti-Stokes Raman spectroscopy via SU(1,1) interferometry

Taj Kumar, Gaurav K. Shukla, Devendra Kumar Mishra

Published Jan 25, 2025• 4 citations
Publisher
DOI
10.1007/s00340-024-08382-y

Related papers

Stark Dynamics and Saturation in Resonant Coherent Anti-Stokes Raman Spectroscopy

David A. Coppeta, Paul L. Kelley, P. J. Harshman +2 more

Springer eBooks•Jan 1, 1996•0 citations

Electronic Coherent Anti-Stokes Raman Spectroscopy in CeF{sub 3}

David Piehler

•Nov 1, 1990•0 citations

Optimal quantum measurement of finite-dimensional systems and coherent anti-Stokes Raman spectroscopy

Fang Gao, Yao-xiong Wang, Feng Shuang

Chinese Science Bulletin•May 3, 2012•2 citations

Coherent anti-Stokes Raman scattering with squeezed light: CARS for quantum-enhanced spectroscopy and imaging

Santiago Pinto, Frank Hagelberg, Ali Passian +1 more

Physical Review A•Dec 8, 2025•0 citations

Squeezing-enhanced Raman spectroscopy

Yoad Michael, Leon Bello, M. Rosenbluh +1 more

Abstract The sensitivity of classical Raman spectroscopy methods, such as coherent anti-stokes Raman spectroscopy (CARS) or stimulated Raman spectroscopy (SRS), is ultimately limited by shot-noise from the stimulating fields. We present the complete theoretical analysis of a squeezing-enhanced version of Raman spectroscopy that overcomes the shot-noise limit of sensitivity with enhancement of the Raman signal and inherent background suppression, while remaining fully compatible with standard Raman spectroscopy methods. By incorporating the Raman sample between two phase-sensitive parametric amplifiers that squeeze the light along orthogonal quadrature axes, the typical intensity measurement of the Raman response is converted into a quantum-limited, super-sensitive estimation of phase. The resonant Raman response in the sample induces a phase shift to signal-idler frequency-pairs within the fingerprint spectrum of the molecule, resulting in amplification of the resonant Raman signal by the squeezing factor of the parametric amplifiers, whereas the non-resonant background is annihilated by destructive interference. Seeding the interferometer with classical coherent light stimulates the Raman signal further without increasing the background, effectively forming squeezing-enhanced versions of CARS and SRS, where the quantum enhancement is achieved on top of the classical stimulation.

arXiv:1808.08572•npj Quantum Information•Oct 1, 2019•58 citations

Coherent Anti-Stokes Raman Scattering

J. P. Taran

Springer eBooks•Jan 1, 1981•2 citations
Abstract The sensitivity of classical Raman spectroscopy methods, such as coherent anti-stokes Raman spectroscopy (CARS) or stimulated Raman spectroscopy (SRS), is ultimately limited by shot-noise from the stimulating fields. We present the complete theoretical analysis of a squeezing-enhanced version of Raman spectroscopy that overcomes the shot-noise limit of sensitivity with enhancement of the Raman signal and inherent background suppression, while remaining fully compatible with standard Raman spectroscopy methods. By incorporating the Raman sample between two phase-sensitive parametric amplifiers that squeeze the light along orthogonal quadrature axes, the typical intensity measurement of the Raman response is converted into a quantum-limited, super-sensitive estimation of phase. The resonant Raman response in the sample induces a phase shift to signal-idler frequency-pairs within the fingerprint spectrum of the molecule, resulting in amplification of the resonant Raman signal by the squeezing factor of the parametric amplifiers, whereas the non-resonant background is annihilated by destructive interference. Seeding the interferometer with classical coherent light stimulates the Raman signal further without increasing the background, effectively forming squeezing-enhanced versions of CARS and SRS, where the quantum enhancement is achieved on top of the classical stimulation.