Abstract The sensitivity of classical Raman spectroscopy methods, such as coherent anti-stokes Raman spectroscopy (CARS) or stimulated Raman spectroscopy (SRS), is ultimately limited by shot-noise from the stimulating fields. We present the complete theoretical analysis of a squeezing-enhanced version of Raman spectroscopy that overcomes the shot-noise limit of sensitivity with enhancement of the Raman signal and inherent background suppression, while remaining fully compatible with standard Raman spectroscopy methods. By incorporating the Raman sample between two phase-sensitive parametric amplifiers that squeeze the light along orthogonal quadrature axes, the typical intensity measurement of the Raman response is converted into a quantum-limited, super-sensitive estimation of phase. The resonant Raman response in the sample induces a phase shift to signal-idler frequency-pairs within the fingerprint spectrum of the molecule, resulting in amplification of the resonant Raman signal by the squeezing factor of the parametric amplifiers, whereas the non-resonant background is annihilated by destructive interference. Seeding the interferometer with classical coherent light stimulates the Raman signal further without increasing the background, effectively forming squeezing-enhanced versions of CARS and SRS, where the quantum enhancement is achieved on top of the classical stimulation.
Abstract The sensitivity of classical Raman spectroscopy methods, such as coherent anti-stokes Raman spectroscopy (CARS) or stimulated Raman spectroscopy (SRS), is ultimately limited by shot-noise from the stimulating fields. We present the complete theoretical analysis of a squeezing-enhanced version of Raman spectroscopy that overcomes the shot-noise limit of sensitivity with enhancement of the Raman signal and inherent background suppression, while remaining fully compatible with standard Raman spectroscopy methods. By incorporating the Raman sample between two phase-sensitive parametric amplifiers that squeeze the light along orthogonal quadrature axes, the typical intensity measurement of the Raman response is converted into a quantum-limited, super-sensitive estimation of phase. The resonant Raman response in the sample induces a phase shift to signal-idler frequency-pairs within the fingerprint spectrum of the molecule, resulting in amplification of the resonant Raman signal by the squeezing factor of the parametric amplifiers, whereas the non-resonant background is annihilated by destructive interference. Seeding the interferometer with classical coherent light stimulates the Raman signal further without increasing the background, effectively forming squeezing-enhanced versions of CARS and SRS, where the quantum enhancement is achieved on top of the classical stimulation.
Quantum correlations offer the possibility of surpassing classical limits in optical measurements, but their integration into nonlinear vibrational spectroscopy has remained largely unexplored. Here, we introduce a quantum-enhanced implementation of coherent Raman spectroscopy that employs broadband squeezed-light detection to interrogate relative intensity correlations between Stokes and anti-Stokes fields generated in an ultrafast four-wave-mixing process. By exploiting nonclassical correlations between these fields, we suppress the nonresonant background and enhance the signal-to-noise performance in both temporal and spectral domains, enabling detection sensitivities beyond the classical shot-noise limit. Importantly, the quantum advantage demonstrated here does not arise solely from improved detection statistics. Rather, it originates from microscopic intermolecular correlations mediated by cascaded exchange of a virtual photon between molecular pairs. This mechanism establishes a fundamentally distinct and significant pathway for information extraction in vibrational spectroscopy, providing access to structural and dynamical observables that are intrinsically inaccessible by conventional classical Raman techniques. Numerical simulations illustrate the power of the technique by resolving intradimer [Formula: see text] bond splitting in cyclobutane thymine dimers following ultraviolet excitation, highlighting its potential for probing ultrafast photochemical processes with quantum-limited sensitivity and for label-free biomedical optical sensing and imaging.
In many state-of-the-art stimulated Raman spectroscopy (SRS) experiments, shot noise is the dominating noise source. We apply polarization-squeezed light generated in a silica fiber via the Kerr effect for SRS. The non-classical state of light allows for lowering the noise power below the shot noise limit, which enhances the signal-to-noise ratio (SNR). In our experiment, we achieved 3.0 dB SNR improvement when compared to coherent state SRS. We additionally investigate spectral focusing of squeezed pulses to improve SRS resolution without loss in SNR.
Stimulated Raman scattering (SRS) microscopy has emerged as a powerful technique for probing the spatiotemporal dynamics of molecular bonds with exceptional sensitivity, resolution, and speed. However, classically, its performance remains fundamentally constrained by optical shot noise, which imposes a strict limit on detection sensitivity and speed. Here, we demonstrate a quantum-enhanced SRS microscopy platform that circumvents this barrier by harnessing amplitude-squeezed light. Specifically, we generate a Stokes beam with 5.2dB of amplitude squeezing using traveling-wave optical parametric amplification in second-order nonlinear waveguides, and combine it with a tunable coherent pump to access vibrational modes spanning from 1000 to 3100cm−1. Applied to quantum imaging of metabolites in biological tissue (pork muscle), our quantum-enhanced Raman microscope achieves an average noise suppression of 3.6dB and a 51% enhancement in signal-to-noise ratio (SNR) -- to the best of our knowledge, the largest improvement reported to date in quantum-enhanced SRS microscopy of biological samples.
Quantum-enhanced stimulated Raman scattering (QE-SRS) becomes a powerful method for high-sensitivity molecular vibrational spectroscopy and imaging by breaking the shot-noise-limited sensitivity of classical SRS. However, it’s still challenging to achieve quantum-enhancement with typical pulse power (<10-mW) for SRS. Although amplitude-squeezing technique was utilized in the previous QE-SRS, it limits the available optical power by its deamplification or optical loss at asymmetric beamsplitter. To circumvent this problem, we propose and demonstrate SRS spectroscopy with quantum-enhanced balanced detection (QE-BD) scheme, where squeezed vacuum (SQV) is combined with a strong local oscillator (LO) to enhance the sensitivity of SRS. We generated SQV at the central wavelength of 844-nm, using a periodically-poled stoichiometric LiTaO3 waveguide. Picosecond LO light is modulated by a spatial light modulator to achieve spatial matching with SQV , and resultant high squeezing level. At each photodiode, LO has ~10-mW optical power, and –3.1-dB squeezing level was observed. To obtain the QE-SRS spectrum of dimethyl sulfoxide-d6 (d-DMSO), we scanned the wavelength of Stokes laser by a high-speed spectral scanner composed of a grating and galvanometric scanner . The QE-SRS spectrum in the wavenumber range of 1950-2300-cm-1 was acquired with 2.1-dB signal-to-noise ratio (SNR) improvement compared with classical shot-noise-limited SRS under balanced-detection. The proposed QE-BD SRS paves the way for QE-SRS with high-power pulses, and shows a potential to exceed the SNR of state-of-the-art classical SRS system without quantum enhancement
Stimulated Raman spectroscopy has become a powerful tool to study the spatiodynamics of molecular bonds with high sensitivity, resolution, and speed. However, the sensitivity and speed of state-of-the-art stimulated Raman scattering spectroscopy are currently limited by the shot-noise of the light beam probing the Raman process. Here, we demonstrate in a proof-of-principle experiment an enhancement of the sensitivity of continuous-wave stimulated Raman spectroscopy by reducing the quantum noise of the probing light below the shot-noise limit by means of amplitude squeezed states of light. Probing polymer samples with Raman shifts around 2950 c m − 1 with squeezed states, we demonstrate a quantum enhancement of the stimulated Raman signal-to-noise ratio (SNR) of 3.60 dB relative to the shot-noise limited SNR. Our proof-of-concept demonstration of quantum-enhanced continuous-wave Raman spectroscopy paves the way for more elaborate demonstrations using state-of-the-art stimulated Raman scattering microscopes, and thus constitutes the very first step towards a new generation of Raman microscopes, where weak Raman transitions can be imaged without the use of markers or an increase in the total optical power.
In optical microscopy, as in any biological measurement performed with light, there is a compromise between increasing power to improve resolution and decreasing power to prevent photodamage to the biological structure. Quantum optics allows this compromise to be overcome, enabling improved precision without increased illumination intensity. This thesis demonstrates, for the first time, absolute quantum advantage in microscopy, with a specific focus on Stimulated Raman Scattering (SRS) microscopy.SRS microscopy is a powerful tool widely used in many fields, especially in biomedical sciences. It uses a two-photon process where the light is downshifted in frequency by being absorbed and subsequently inelastically scattered by the intrinsic molecular vibrations in the sample. Each element or molecule has a different response, allowing selective imaging of biological systems. SRS microscopy is particularly useful because it is label-free (no addition of dyes, beads or any implanted tracer), meaning that imaging contrast is achieved without modification of, or interference with, the specimen. Here I present our newly built state-of-the-art shot-noise limited SRS microscope. I also characterize the Raman microscope, describe the developped imaging system and show SRS spectroscopy and imaging of both polystyrene beads and living yeast cells.The quantisation of light introduces a fundamental uncertainty, or quantum noise, in both the amplitude and phase quadratures of an optical field. A squeezed state of light is a state of the optical field where the uncertainty of one of these quadratures is reduced below the quantum noise. Therefore, it provides an approach to reduce the noise level below this quantum noise limit and consequently increases measured signal-to-noise ratio. Here I describe the concepts involved in this technique and present our newly built light squeezer. I characterize the squeezing and show up to -1.3 dB of noise floor reduction for a 6 picosecond pulsed laser, which is the pulse duration that maximises the Raman interaction.In this thesis we apply squeezed states of light in SRS, developping a quantum-enhanced micro- scope. Our SRS Raman intensity noise is ∆I/I ≈ 10^(−7) and the measured quantum efficiency of the built photodiode is η = 72%. In this proof of principle we show a reduction of the noise floor of at least 13% below the quantum noise limit for Raman imaging of polystyrene beads and living yeast cells. This enhancement allowed us to resolve the cell membrane where with conventional microscope would be unresolvable. It also allowed sub-micron spatial resolution. The improved image contrast and reduced imaging time, while avoiding photodamage in the sample, surpasses the current state-of-the-art Raman microscopes and opens opportunities for new discoveries in biophysics.