Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

High-contrast absorption magnetometry in the visible to near-infrared range with nitrogen-vacancy ensembles

Florian Schall, Felix A. Hahl, Lukas Lindner, Xavier Vidal, Tingpeng Luo, Alexander M. Zaitsev, Takeshi Ohshima, Jan Jeske, Rüdiger Quay

Published Jan 23, 2025• 2 citations
Publisher

Abstract

Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.

DOI
10.1364/oe.550716

Related papers

Characterizing the nitrogen-vacancy center singlet transition and its phonon sideband for absorption-based room-temperature magnetometry

Tobias Probst, Florian Schall, Sebastian Heuft +9 more

Magnetometry with nitrogen-vacancy (NV) centers in diamond has shown great promise in recent years. In particular, absorption-based magnetometry techniques, employing a cavity to enhance the absorption length, can improve the contrast and sensitivity compared to conventional techniques based on reading out the NV$^-$ triplet fluorescence. The absorption techniques rely on magnetic-field-dependent absorption at the NV$^-$ singlet zero phonon line at 1042$\,$nm and its phonon sideband. In a cavity-enhanced spectroscopy approach, we study pump-laser- and microwave-induced cavity signal changes at room temperature over a spectral range of 680-1050$\,$nm. Through normalization, we eliminate the cavity-enhancement effect and provide quasi-single-pass values for the absorption and optically detected magnetic resonance (ODMR) contrast. The highest contrast is found at 1042$\,$nm, but multiple points of high contrast are found at the peaks of the phonon sideband. Additionally, cavity-enhanced ODMR contrasts in the range of 50-80$\,\%$ are presented. We further measure the broadband singlet absorption cross section at room temperature with a novel method through microwave-induced signal changes. This method is insensitive to pump-laser-induced signal changes by other defects and quantifies the room-temperature absorption strength of the singlet transition and its entire phonon sideband. We determine the absorption cross section at 1042$\,$nm to be $σ^{\,\bigstar}_{1042}=(0.89\pm0.14)\cdot 10^{-21}\,\text{m}^2$ or $σ^{\,\blacktriangle}_{1042}=(2.9\pm0.5)\cdot 10^{-21}\,\text{m}^2$. depending on the employed 532$\,$nm NV$^-$ absorption cross section.

quant-pharXiv:2608.02060•Aug 4, 2026•0 citations

A robust laser cavity platform for NV-diamond singlet infrared absorption magnetometry

Shao Qi Lim, Alexander A. Wood, Brett C. Johnson +9 more

The negatively charged nitrogen-vacancy center (NV$^-$) in diamond is a versatile platform for quantum magnetometry under ambient conditions. Recently, laser threshold magnetometry (LTM) has been proposed as a means to significantly enhance the sensitivity of NV-based magnetometers by incorporating a diamond hosting NV$^-$ centers within a laser cavity and operating near threshold. While demonstrations have validated the concept, practical implementations remain technically demanding, requiring high pump powers and precise alignment of free-space cavities. It remains unclear whether the benefits of operating near threshold will outpace increased laser noise. In this work, we integrate an NV-diamond with a high NV$^-$ content into a compact external cavity diode laser and demonstrate singlet infrared absorption optically detected magnetic resonance (ODMR). The system exhibits exceptional threshold current stability, enabling ODMR using the threshold current as the read-out parameter. We report a five-fold enhancement in the ODMR contrast by operating near threshold. The best magnetic field sensitivity of $7.6~\mathrm{nT/\sqrt{Hz}}$ (DC-500 Hz) is achieved well above threshold, while near threshold sensitivity is limited by increased probe laser noise. These results establish a compact and mechanically robust platform for singlet absorption-based NV$^-$ magnetometry and highlight key trade-offs between contrast enhancement and laser noise near threshold.

quant-pharXiv:2604.18937•Apr 22, 2026•0 citations

Towards high-sensitivity magnetometry with nitrogen-vacancy centers in diamond using the singlet infrared absorption

Ali Tayefeh Younesi, Muhib Omar, Arne Wickenbrock +2 more

The negatively charged nitrogen vacancy center in diamond is widely used for quantum sensing due to the sensitivity of the spin triplet in the electronic ground state to external perturbations such as strain and electromagnetic fields, which makes it an excellent probe for changes in these perturbations. The spin state can be measured through optically detected magnetic resonance, which is most commonly achieved by detecting the photoluminescence after exciting the spin-triplet transition. Recently, methods have been proposed and demonstrated that use the absorption of the infrared singlet transition at 1042 nm instead. These methods, however, require cryogenic temperatures or external cavities to enhance the absorption signal. Here, we report on our efforts to optimize the magnetometer sensitivity at room temperature and without cavities. We reach a sensitivity of 18 pT / Hz , surpassing previously reported values, and a calculated shot-noise limit of 5 pT / Hz . We also report on a defect that is native to diamond grown by chemical vapor deposition and thus absent in high-pressure high-temperature diamond, the excitation of which impacts the measured singlet absorption signal.

arXiv:2410.20876•Physical Review Applied•May 7, 2025•13 citations

Telecom-Wavelength-Compatible Quantum Information Transcription Using Nitrogen-Vacancy Centers

B. Göblyös, S. Kollarics, R. Kucsera +5 more

Nitrogen-vacancy (NV) centers in diamond are a leading platform for solid-state quantum sensing and quantum information processing. While most optical studies rely on the visible fluorescence associated with the triplet transitions, the infrared singlet transition near $1042$ nm, which is typically considered dark within the singlet manifold of the NV optical cycle, provides an alternative optical channel. Here, we report wavelength-resolved optically detected magnetic resonance (ODMR) measurements of this infrared emission. We directly observe ODMR contrast in the $1042$ nm emission and analyze its dependence on the magnetic field. The field-dependent spectral dispersion of the ODMR signal demonstrates that the spin-state information encoded in the NV center is transcribed to the infrared singlet emission through the spin-selective intersystem crossing, in close analogy to the visible fluorescence readout. These results establish infrared ODMR as a high-fidelity optical readout pathway. Crucially, by extending spin-state transcription directly into the $1300-1600$ nm range, this work demonstrates a direct, conversion-free interface between diamond spin-qubits and standard telecommunication infrastructure, bypassing the efficiency bottlenecks of active frequency conversion and benefiting from the already well-developed technologies in this range of the electromagnetic spectrum.

cond-mat.mtrl-sciCross-listedarXiv:2605.14697•May 15, 2026•0 citations

Towards high-sensitivity magnetometry with nitrogen-vacancy centers in diamond using the singlet infrared absorption

Tayefeh Younesi, Ali, Omar, Muhib, Arne Wickenbrock +2 more

The negatively charged nitrogen vacancy center in diamond is widely used for quantum sensing due to the sensitivity of the spin triplet in the electronic ground state to external perturbations such as strain and electromagnetic fields, which makes it an excellent probe for changes in these perturbations.The spin state can be measured through optically detected magnetic resonance, which is most commonly achieved by detecting the photoluminescence after exciting the spin-triplet transition.Recently, methods have been proposed and demonstrated that use the absorption of the infrared singlet transition at 1042 nm instead.These methods, however, require cryogenic temperatures or external cavities to enhance the absorption signal.Here, we report on our efforts to optimize the magnetometer sensitivity at room temperature and without cavities.We reach a sensitivity of 18 pT/ √ Hz, surpassing previously reported values, and a calculated shot-noise limit of 5 pT/ √ Hz .We also report on a defect that is native to diamond grown by chemical vapor deposition and thus absent in high-pressure high-temperature diamond, the excitation of which impacts the measured singlet absorption signal.

Physical Review Applied•Jan 1, 2025•0 citations

Magnetometry with nitrogen-vacancy ensembles in diamond based on infrared absorption in a doubly resonant optical cavity

Yannick Dumeige, Mayeul Chipaux, V. Jacques +8 more

We propose using an optical cavity to enhance the sensitivity of a magnetometer relying on the detection of the spin state of a high-density nitrogen-vacancy ensemble in diamond using infrared optical absorption. The role of the cavity is to obtain a contrast in the absorption-detected magnetic resonance approaching unity at room temperature. We project an increase in the photon shot-noise limited sensitivity of two orders of magnitude in comparison with a single-pass approach. Optical losses can limit the enhancement to one order of magnitude, which could still enable room-temperature operation. Finally, the optical cavity also allows us to use less pumping power when the cavity is resonant at both the pump and the infrared probe wavelength.

arXiv:1301.0808•Physical Review B•Apr 8, 2013•77 citations
Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.
Magnetometry with nitrogen-vacancy (NV) centers in diamond has shown great promise in recent years. In particular, absorption-based magnetometry techniques, employing a cavity to enhance the absorption length, can improve the contrast and sensitivity compared to conventional techniques based on reading out the NV−^-− triplet fluorescence. The absorption techniques rely on magnetic-field-dependent absorption at the NV−^-− singlet zero phonon line at 1042 \,nm and its phonon sideband. In a cavity-enhanced spectroscopy approach, we study pump-laser- and microwave-induced cavity signal changes at room temperature over a spectral range of 680-1050 \,nm. Through normalization, we eliminate the cavity-enhancement effect and provide quasi-single-pass values for the absorption and optically detected magnetic resonance (ODMR) contrast. The highest contrast is found at 1042 \,nm, but multiple points of high contrast are found at the peaks of the phonon sideband. Additionally, cavity-enhanced ODMR contrasts in the range of 50-80 %\,\%% are presented. We further measure the broadband singlet absorption cross section at room temperature with a novel method through microwave-induced signal changes. This method is insensitive to pump-laser-induced signal changes by other defects and quantifies the room-temperature absorption strength of the singlet transition and its entire phonon sideband. We determine the absorption cross section at 1042 \,nm to be σ1042 ★=(0.89±0.14)⋅10−21 m2σ^{\,\bigstar}_{1042}=(0.89\pm0.14)\cdot 10^{-21}\,\text{m}^2σ1042★​=(0.89±0.14)⋅10−21m2 or σ1042 ▲=(2.9±0.5)⋅10−21 m2σ^{\,\blacktriangle}_{1042}=(2.9\pm0.5)\cdot 10^{-21}\,\text{m}^2σ1042▲​=(2.9±0.5)⋅10−21m2. depending on the employed 532 \,nm NV−^-− absorption cross section.
The negatively charged nitrogen-vacancy center (NV−^-−) in diamond is a versatile platform for quantum magnetometry under ambient conditions. Recently, laser threshold magnetometry (LTM) has been proposed as a means to significantly enhance the sensitivity of NV-based magnetometers by incorporating a diamond hosting NV−^-− centers within a laser cavity and operating near threshold. While demonstrations have validated the concept, practical implementations remain technically demanding, requiring high pump powers and precise alignment of free-space cavities. It remains unclear whether the benefits of operating near threshold will outpace increased laser noise. In this work, we integrate an NV-diamond with a high NV−^-− content into a compact external cavity diode laser and demonstrate singlet infrared absorption optically detected magnetic resonance (ODMR). The system exhibits exceptional threshold current stability, enabling ODMR using the threshold current as the read-out parameter. We report a five-fold enhancement in the ODMR contrast by operating near threshold. The best magnetic field sensitivity of 7.6 nT/Hz7.6~\mathrm{nT/\sqrt{Hz}}7.6 nT/Hz​ (DC-500 Hz) is achieved well above threshold, while near threshold sensitivity is limited by increased probe laser noise. These results establish a compact and mechanically robust platform for singlet absorption-based NV−^-− magnetometry and highlight key trade-offs between contrast enhancement and laser noise near threshold.
The negatively charged nitrogen vacancy center in diamond is widely used for quantum sensing due to the sensitivity of the spin triplet in the electronic ground state to external perturbations such as strain and electromagnetic fields, which makes it an excellent probe for changes in these perturbations. The spin state can be measured through optically detected magnetic resonance, which is most commonly achieved by detecting the photoluminescence after exciting the spin-triplet transition. Recently, methods have been proposed and demonstrated that use the absorption of the infrared singlet transition at 1042 nm instead. These methods, however, require cryogenic temperatures or external cavities to enhance the absorption signal. Here, we report on our efforts to optimize the magnetometer sensitivity at room temperature and without cavities. We reach a sensitivity of 18 pT / Hz , surpassing previously reported values, and a calculated shot-noise limit of 5 pT / Hz . We also report on a defect that is native to diamond grown by chemical vapor deposition and thus absent in high-pressure high-temperature diamond, the excitation of which impacts the measured singlet absorption signal.
Nitrogen-vacancy (NV) centers in diamond are a leading platform for solid-state quantum sensing and quantum information processing. While most optical studies rely on the visible fluorescence associated with the triplet transitions, the infrared singlet transition near 104210421042 nm, which is typically considered dark within the singlet manifold of the NV optical cycle, provides an alternative optical channel. Here, we report wavelength-resolved optically detected magnetic resonance (ODMR) measurements of this infrared emission. We directly observe ODMR contrast in the 104210421042 nm emission and analyze its dependence on the magnetic field. The field-dependent spectral dispersion of the ODMR signal demonstrates that the spin-state information encoded in the NV center is transcribed to the infrared singlet emission through the spin-selective intersystem crossing, in close analogy to the visible fluorescence readout. These results establish infrared ODMR as a high-fidelity optical readout pathway. Crucially, by extending spin-state transcription directly into the 1300−16001300-16001300−1600 nm range, this work demonstrates a direct, conversion-free interface between diamond spin-qubits and standard telecommunication infrastructure, bypassing the efficiency bottlenecks of active frequency conversion and benefiting from the already well-developed technologies in this range of the electromagnetic spectrum.
The negatively charged nitrogen vacancy center in diamond is widely used for quantum sensing due to the sensitivity of the spin triplet in the electronic ground state to external perturbations such as strain and electromagnetic fields, which makes it an excellent probe for changes in these perturbations.The spin state can be measured through optically detected magnetic resonance, which is most commonly achieved by detecting the photoluminescence after exciting the spin-triplet transition.Recently, methods have been proposed and demonstrated that use the absorption of the infrared singlet transition at 1042 nm instead.These methods, however, require cryogenic temperatures or external cavities to enhance the absorption signal.Here, we report on our efforts to optimize the magnetometer sensitivity at room temperature and without cavities.We reach a sensitivity of 18 pT/ √ Hz, surpassing previously reported values, and a calculated shot-noise limit of 5 pT/ √ Hz .We also report on a defect that is native to diamond grown by chemical vapor deposition and thus absent in high-pressure high-temperature diamond, the excitation of which impacts the measured singlet absorption signal.
We propose using an optical cavity to enhance the sensitivity of a magnetometer relying on the detection of the spin state of a high-density nitrogen-vacancy ensemble in diamond using infrared optical absorption. The role of the cavity is to obtain a contrast in the absorption-detected magnetic resonance approaching unity at room temperature. We project an increase in the photon shot-noise limited sensitivity of two orders of magnitude in comparison with a single-pass approach. Optical losses can limit the enhancement to one order of magnitude, which could still enable room-temperature operation. Finally, the optical cavity also allows us to use less pumping power when the cavity is resonant at both the pump and the infrared probe wavelength.