Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Impact of Thermal Induced Magnetic Noise on the Sensitivity of Atomic Magnetometers

Ning Zhang, Zixuan Wang, Qiang Guo

Published Jan 1, 2025• 0 citations
Publisher
DOI
10.2139/ssrn.5090523

Related papers

In Situ Suppression of Thermal–Magnetic Coupling Noise in Atomic Sensors

Yijin Liu, Bin Wang, Di Gong +4 more

Spin-based sensors, such as magnetometers and comagnetometers, require precise control of thermal conditions and magnetic fields to achieve optimal performance. Thermal-magnetic coupling noise, induced by heating systems, is one of the limiting factors for sensitivity improvement. In this paper, the in-situ suppression method is proposed to eliminate thermal-magnetic coupling noise by employing the double-layer heater with dynamically adjustable current ratios. The in-situ method is verified across two distinct systems, including commercial magnetometer and the self-developed comagnetometer. For magnetometer system, the heating-induced magnetic interferences of the double-layer heater along three directions have been decreased over 2 orders compared to a conventional heater. Similarly, the total magnetic flux density has been suppressed by more than 78%. Furthermore, the thermal-magnetic coupling noise in K-Rb-21Ne comagnetometer equipped with the double-layer heater is in-situ suppressed to 6.54×10-9°/s/Hz1/2(0.01 fT/ Hz1/2) at 1 Hz, achieving a noise reduction of 22 dB compared to ex-situ method and 24 dB suppression relative to a conventional heater. Besides, the double-layer heater ensures a uniform and stable thermal field across the vapor cell, with a temperature variance less than 0.65 °C and a temperature fluctuation 65% lower than a conventional heater. This work advances ultra-sensitive quantum sensors by providing an effective method to in-situ suppress thermal-magnetic coupling noise.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Quantum noise in atomic magnetometers

Michael V. Romalis

Cambridge University Press eBooks•Mar 7, 2013•6 citations

Miniature atomic magnetometer integrated with flux concentrators

W. C. Griffith, Ricardo Jiménez-Martínez, Vishal Shah +2 more

High permeability magnetic flux concentrators are used to enhance the sensitivity of an atomic magnetometer operating in the spin-exchange relaxation-free regime. The magnetometer uses a millimeter scale Rb87 vapor cell and either mu-metal or Mn–Zn ferrite flux concentrators. The measured sensitivity gives excellent agreement with calculations of thermal noise from the concentrator material. The mu-metal concentrators allow a sensitivity of 50fTHz−1∕2, limited by thermal current magnetic noise. The ferrite concentrators are limited by thermal magnetization noise at low frequencies, and reach a sensitivity of 10fTHz−1∕2 for frequencies above 125Hz.

Applied Physics Letters•Jan 12, 2009•75 citations

Experimental Investigation on a Highly Sensitive Atomic Magnetometer

李曙光, 徐云飞, 王兆英 +2 more

Chinese Physics Letters•Jan 1, 2009•1 citation

High Frequency Atomic Magnetometer by Use of Electromagnetically Induced Transparency

George E. Katsoprinakis, David Petrosyan, Iannis K. Kominis

Atomic magnetometers have achieved magnetic sensitivities in the subfemtotesla regime. Their bandwidth is determined by the transverse spin relaxation rate, 1/T2, which also determines the magnetic sensitivity. It is theoretically demonstrated that by using an electromagnetically induced transparent probe beam in a pump-probe atomic magnetometer, it is possible to operate the latter at frequencies much higher than its bandwidth, maintaining a high signal-to-noise ratio.

Physical Review Letters•Dec 6, 2006•26 citations

Progress in high sensitive atomic magnetometers

Guobin Liu, Xian-Ping Sun, 顾思洪 +2 more

Wuli•Jan 1, 2012•1 citation
Spin-based sensors, such as magnetometers and comagnetometers, require precise control of thermal conditions and magnetic fields to achieve optimal performance. Thermal-magnetic coupling noise, induced by heating systems, is one of the limiting factors for sensitivity improvement. In this paper, the in-situ suppression method is proposed to eliminate thermal-magnetic coupling noise by employing the double-layer heater with dynamically adjustable current ratios. The in-situ method is verified across two distinct systems, including commercial magnetometer and the self-developed comagnetometer. For magnetometer system, the heating-induced magnetic interferences of the double-layer heater along three directions have been decreased over 2 orders compared to a conventional heater. Similarly, the total magnetic flux density has been suppressed by more than 78%. Furthermore, the thermal-magnetic coupling noise in K-Rb-21Ne comagnetometer equipped with the double-layer heater is in-situ suppressed to 6.54×10-9°/s/Hz1/2(0.01 fT/ Hz1/2) at 1 Hz, achieving a noise reduction of 22 dB compared to ex-situ method and 24 dB suppression relative to a conventional heater. Besides, the double-layer heater ensures a uniform and stable thermal field across the vapor cell, with a temperature variance less than 0.65 °C and a temperature fluctuation 65% lower than a conventional heater. This work advances ultra-sensitive quantum sensors by providing an effective method to in-situ suppress thermal-magnetic coupling noise.
High permeability magnetic flux concentrators are used to enhance the sensitivity of an atomic magnetometer operating in the spin-exchange relaxation-free regime. The magnetometer uses a millimeter scale Rb87 vapor cell and either mu-metal or Mn–Zn ferrite flux concentrators. The measured sensitivity gives excellent agreement with calculations of thermal noise from the concentrator material. The mu-metal concentrators allow a sensitivity of 50fTHz−1∕2, limited by thermal current magnetic noise. The ferrite concentrators are limited by thermal magnetization noise at low frequencies, and reach a sensitivity of 10fTHz−1∕2 for frequencies above 125Hz.