Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Scientific Reports

Optimising detector readout settings for the detection of spatial correlations between SPDC photon-pairs

K. Roberts, Thomas Gregory, Osian Wolley, Miles J. Padgett

Published Jan 7, 2025• 2 citations
Publisher

Abstract

SPDC photon-pairs exhibit spatial correlations which can be measured using detector arrays sensitive to single photons. However, these detector arrays have multiple readout modes and in order to optimise detection it is important to select the optimum mode to detect the correlations against a background of optical and electronic noise. These quantum correlations enable applications in imaging, sensing, communication, and optical processing. Here we compare the measurement of spatial correlations for a broad range of readout modes of an EMCCD camera and attempt to characterise the optimal readout mode for our purposes. This assessment is important for the use of detector arrays of different types for use in quantum, low-light, enhanced resolution, imaging systems.

DOI
10.1038/s41598-024-84200-x

Related papers

Full field measurement of spatial correlated photon pairs with an EMCCD camera

M. Edgar, D. S. Tasca, Frauke Izdebski +5 more

The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.

•Jan 1, 2012•0 citations

Quantum correlations measured with multi-pixel detectors

Frauke Izdebski

use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-

•Aug 1, 2013•0 citations

Quantum imaging with a photon counting camera

Osian Wolley, Thomas Gregory, Sebastian M. J. Beer +2 more

Classical light sources emit a randomly-timed stream of individual photons, the spatial distribution of which can be detected with a camera to form an image. Quantum light sources, based on parametric down conversion, emit photons as correlated photon-pairs. The spatial correlations between the photons enables imaging systems where the preferential selection of photon-pairs allows for enhancements in the noise performance over what is possible using classical light sources. However, until now the technical challenge of measuring, and correlating both photons has led to system complexity. Here we show that a camera capable of resolving the number of individual photons in each pixel of the detector array can be used to record an image formed from these photon-pair events and hence achieve a greater contrast than possible using a classical light source. We achieve an enhancement in the ratio of two-photon events compared to one-photon events using spatially correlated SPDC light compared to uncorrelated illumination by a LED. These results indicate the potential advantages of using photon counting cameras in quantum imaging schemes and these advantages will further increase as the technology is developed. Operating in photon sparse regimes such systems have potential applications in low-light microscopy and covert imaging.

Scientific Reports•May 18, 2022•47 citations

A comparison between the measurement of quantum spatial correlations using qCMOS photon-number resolving and electron multiplying CCD camera technologies

K. Roberts, Osian Wolley, Thomas Gregory +1 more

Cameras with single-photon sensitivities can be used to measure the spatial correlations between the photon-pairs that are produced by parametric down-conversion. Even when pumped by a single-mode laser, the signal and idler photons are typically distributed over several thousand spatial modes yet strongly correlated with each other in their position and anti-correlated in their transverse momentum. These spatial correlations enable applications in imaging, sensing, communication, and optical processing. Here we show that, using a photon-number resolving camera, spatial correlations can be observed after only a few 10s of seconds of measurement time, thereby demonstrating comparable performance with previous single photon sensitive camera technologies but with the additional capability to resolve photon-number. Consequently, these photon-number resolving technologies are likely to find wide use in quantum, low-light, imaging systems.

Scientific Reports•Jun 26, 2024•11 citations

Real-time Processing of Correlated Photons for Quantum Imaging

Isaac Reichman, Gilad Pollack, Hadar Aharon +1 more

Quantum imaging leverages nonclassical correlations to reveal features that may vanish in conventional event integration [ 1, 2]. While single-photon detectors are well-established, quantum imaging demands complex data acquisition across many thousands of detectors, each generating rich metadata including triggering time, duration, and other properties. Consequently, effective data management, data wrangling, and correlation extraction become critical challenges. In this work, we investigate optimal handling of spatial correlations from a quantum-photonic source (spontaneous parametric down-conversion, SPDC) using an emerging single-photon event-based camera, the TPX3CAM (256×256 array, supported by an intensifier). Utilizing a femtosecond photon-pair source, we comprehensively analyse noise characteristics, including temporal dynamics and spatial distribution, to develop advanced spatio-temporal noise suppression strategies tailored to camera performance. Our primary objectives include real-time isolation and preprocessing of correlative data. Our analysis demonstrates the potential of these real-time correlation detection and noise reduction algorithms to expand quantum imaging capabilities across diverse scientific domains. Potential applications include high-resolution spectroscopy in biology, materials science, and advanced electron microscopy, where these techniques could enable identification of cascaded two-photon processes with atomic-scale precision. Figure 1 shows an excellent example of such a detection in real-space. The ring feature corresponds to the location of the correlated photon-pairs produced from the SPDC process. This is also apparent in figure 2, where we see a strong anti-correlation between the coordinates of the detected photons – corresponding to photon-pairs. <!-- named anchor --> Figure 1: Distribution of SPDC photons on TPX3CAM <!-- named anchor --> Figure 2: Spatial anti-correlation of x-coordinates

•Jan 1, 2025•0 citations

Optimizing the signal-to-noise ratio in the measurement of photon pairs with detector arrays

Éric Lantz, Paul‐Antoine Moreau, F. Devaux

To evidence multimode spatial entanglement of spontaneous down-conversion, detector arrays allow a full-field measurement, without any a priori selection of the paired photons. We show by comparing results of the recent literature that electron-multiplying CCD cameras allow, in the present state of technology, the detection of quantum correlations with the best signal-to-noise ratio (SNR), while intensified CCD cameras allow at best the identification of pairs. The SNR appears to be proportional to the square root of the number of coherence cells in each image, or Schmidt number. Then corrected estimates are derived for extended coherence cells and not-very-low and non-space-stationary photon fluxes. Finally, experimental measurements of the SNR confirm our model.

arXiv:1407.2455•Physical Review A•Dec 9, 2014•20 citations
SPDC photon-pairs exhibit spatial correlations which can be measured using detector arrays sensitive to single photons. However, these detector arrays have multiple readout modes and in order to optimise detection it is important to select the optimum mode to detect the correlations against a background of optical and electronic noise. These quantum correlations enable applications in imaging, sensing, communication, and optical processing. Here we compare the measurement of spatial correlations for a broad range of readout modes of an EMCCD camera and attempt to characterise the optimal readout mode for our purposes. This assessment is important for the use of detector arrays of different types for use in quantum, low-light, enhanced resolution, imaging systems.
The spatial correlations between the photon pairs produced by spontaneous parametric down conversion (SPDC) have been investigated in a number of different configurations over the last two decades (1). The high dimensionality of the transverse spatial degrees of freedom (DOF) of the photon pairs can be explored either by projections onto a discrete (infinite) basis, such as the LG modes, or by using a continuous basis defined by the transverse position or momentum of the photons. For instance, it has been shown that their transverse position and momentum display EPR-type correlations (2). Despite the continuous and unbounded nature of both these bases, the most common measurements to date have relied upon the scanning of a single avalanche photodiode or a very small number of individual detectors. This sequential scanning or small number of detectors negates any information capacity advantage in the use of spatial states. Recent years have seen a rapid advance in imaging technologies, particularly for low light levels. Of these technologies the highest quantum efficiency is achieved using electron multiplying CCDs (EMCCD). Developments in low noise EMCCD cameras suggest they are capable of greater than 80% quantum efficiencies and if operated in an ultra-low light environment whilst being maintained at low temperatures, can provide single photon sensitivity (3). EMCCDs have been used in measurements of sub-shot-noise correlations of intensity fluctuations (4, 5) as well as in intensity correlations measurements (6) in the far field of the photon pairs from SPDC. Here we report the observation of spatial correlations from SPDC using an EMCCD camera in both the image and far-field planes of the down conversion crystal. We pump a BBO crystal at 355nm with a few milli-Watts of optical power and use a simple lens system to relay the down-converted light to an EMCCD array which can be positioned in either the image plane or the far-field of the crystal. Our photon flux is around 1/100 per pixel, which approximately doubles the signal obtained when the light is blocked. We typically record 100,000 individual frames and then sum the auto-correlation of the individual frames. We observed intensity correlation and anti-correlation in the image and far-field planes, respectively. In both cases we make the correlations more visible by subtracting a background which is obtained as the average correlation obtained between successive frames. Using this approach we are able to visualize the strength of the correlations in both position and momentum, showing a variance product nearly one order of magnitude below the classical limit in both x and y directions.
use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-
Classical light sources emit a randomly-timed stream of individual photons, the spatial distribution of which can be detected with a camera to form an image. Quantum light sources, based on parametric down conversion, emit photons as correlated photon-pairs. The spatial correlations between the photons enables imaging systems where the preferential selection of photon-pairs allows for enhancements in the noise performance over what is possible using classical light sources. However, until now the technical challenge of measuring, and correlating both photons has led to system complexity. Here we show that a camera capable of resolving the number of individual photons in each pixel of the detector array can be used to record an image formed from these photon-pair events and hence achieve a greater contrast than possible using a classical light source. We achieve an enhancement in the ratio of two-photon events compared to one-photon events using spatially correlated SPDC light compared to uncorrelated illumination by a LED. These results indicate the potential advantages of using photon counting cameras in quantum imaging schemes and these advantages will further increase as the technology is developed. Operating in photon sparse regimes such systems have potential applications in low-light microscopy and covert imaging.
Cameras with single-photon sensitivities can be used to measure the spatial correlations between the photon-pairs that are produced by parametric down-conversion. Even when pumped by a single-mode laser, the signal and idler photons are typically distributed over several thousand spatial modes yet strongly correlated with each other in their position and anti-correlated in their transverse momentum. These spatial correlations enable applications in imaging, sensing, communication, and optical processing. Here we show that, using a photon-number resolving camera, spatial correlations can be observed after only a few 10s of seconds of measurement time, thereby demonstrating comparable performance with previous single photon sensitive camera technologies but with the additional capability to resolve photon-number. Consequently, these photon-number resolving technologies are likely to find wide use in quantum, low-light, imaging systems.
Quantum imaging leverages nonclassical correlations to reveal features that may vanish in conventional event integration [ 1, 2]. While single-photon detectors are well-established, quantum imaging demands complex data acquisition across many thousands of detectors, each generating rich metadata including triggering time, duration, and other properties. Consequently, effective data management, data wrangling, and correlation extraction become critical challenges. In this work, we investigate optimal handling of spatial correlations from a quantum-photonic source (spontaneous parametric down-conversion, SPDC) using an emerging single-photon event-based camera, the TPX3CAM (256×256 array, supported by an intensifier). Utilizing a femtosecond photon-pair source, we comprehensively analyse noise characteristics, including temporal dynamics and spatial distribution, to develop advanced spatio-temporal noise suppression strategies tailored to camera performance. Our primary objectives include real-time isolation and preprocessing of correlative data. Our analysis demonstrates the potential of these real-time correlation detection and noise reduction algorithms to expand quantum imaging capabilities across diverse scientific domains. Potential applications include high-resolution spectroscopy in biology, materials science, and advanced electron microscopy, where these techniques could enable identification of cascaded two-photon processes with atomic-scale precision. Figure 1 shows an excellent example of such a detection in real-space. The ring feature corresponds to the location of the correlated photon-pairs produced from the SPDC process. This is also apparent in figure 2, where we see a strong anti-correlation between the coordinates of the detected photons – corresponding to photon-pairs. <!-- named anchor --> Figure 1: Distribution of SPDC photons on TPX3CAM <!-- named anchor --> Figure 2: Spatial anti-correlation of x-coordinates
To evidence multimode spatial entanglement of spontaneous down-conversion, detector arrays allow a full-field measurement, without any a priori selection of the paired photons. We show by comparing results of the recent literature that electron-multiplying CCD cameras allow, in the present state of technology, the detection of quantum correlations with the best signal-to-noise ratio (SNR), while intensified CCD cameras allow at best the identification of pairs. The SNR appears to be proportional to the square root of the number of coherence cells in each image, or Schmidt number. Then corrected estimates are derived for extended coherence cells and not-very-low and non-space-stationary photon fluxes. Finally, experimental measurements of the SNR confirm our model.