Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser & Photonics Review

Nanoliter‐Scale Light–Matter Interaction in a Fiber‐Tip Cavity Enables Sensitive Photothermal Gas Detection (Laser Photonics Rev. 18(12)/2024)

Yue Yan, Xunzhou Xiao, Qinxue Nie, Zhen Wang, Yifan Chen, Jiahao Wu, Nansen Zhou, Renjie Zhou, Sen Yang, Wei Ren

Published Dec 1, 2024• 1 citation
Publisher

Abstract

Sensitive Photothermal Gas Detection in a Fiber-Tip Cavity Selective, parts-per-billion level gas-phase chemical detection is achieved within a fiber-tip cavity by harnessing the strong light-matter interaction in a small cavity mode volume. This remarkable detection sensitivity is enabled by an innovative dual-enhanced photothermal technique. The proposed method has the potential to transform fields such as biological analysis, battery diagnostics, molecular spectroscopy in quantum electrodynamics, and the investigation of microscale processes. See article number 2400907 by Sen Yang, Wei Ren, and co-workers.

DOI
10.1002/lpor.202470079

Related papers

A fiber Fabry–Perot cavity with high finesse

D Hunger, T. Steinmetz, Yves Colombe +3 more

We have realized a fiber-based Fabry–Perot cavity with CO 2 laser-machined mirrors. It combines very small size, high finesse , small waist and mode volume, and good mode matching between the fiber and cavity modes. This combination of features is a major advance for cavity quantum electrodynamics (CQED), as shown in recent CQED experiments with Bose–Einstein condensates enabled by this cavity (Colombe Y et al 2007 Nature 450 272). It will also be suitable for a wide range of other applications, including coupling to solid-state emitters, gas detection at the single-particle level, fiber-coupled single-photon sources and high-resolution optical filters with large stopband.

arXiv:1005.0067•New Journal of Physics•Jun 28, 2010•478 citations

Label‐Free Optical Single‐Molecule Micro‐ and Nanosensors

Sivaraman Subramanian, Hsin‐Yu Wu, Tom Constant +2 more

Label-free optical sensor systems have emerged that exhibit extraordinary sensitivity for detecting physical, chemical, and biological entities at the micro/nanoscale. Particularly exciting is the detection and analysis of molecules, on miniature optical devices that have many possible applications in health, environment, and security. These micro- and nanosensors have now reached a sensitivity level that allows for the detection and analysis of even single molecules. Their small size enables an exceedingly high sensitivity, and the application of quantum optical measurement techniques can allow the classical limits of detection to be approached or surpassed. The new class of label-free micro- and nanosensors allows dynamic processes at the single-molecule level to be observed directly with light. By virtue of their small interaction length, these micro- and nanosensors probe light-matter interactions over a dynamic range often inaccessible by other optical techniques. For researchers entering this rapidly advancing field of single-molecule micro- and nanosensors, there is an urgent need for a timely review that covers the most recent developments and that identifies the most exciting opportunities. The focus here is to provide a summary of the recent techniques that have either demonstrated label-free single-molecule detection or claim single-molecule sensitivity.

Advanced Materials•Aug 2, 2018•77 citations

Microfabricated high-finesse optical cavity with open access and small volume

M. Trupke, E. A. Hinds, S. Eriksson +4 more

We present a microfabricated optical cavity, which combines a very small mode volume with high finesse. In contrast to other micro-resonators, such as microspheres, the structure we have built gives atoms and molecules direct access to the high-intensity part of the field mode, enabling them to interact strongly with photons in the cavity for the purposes of detection and quantum-coherent manipulation. Light couples directly in and out of the resonator through an optical fiber, avoiding the need for sensitive coupling optics. This renders the cavity particularly attractive as a component of a lab-on-a-chip, and as a node in a quantum network.

arXiv:quant-ph/0506234•Applied Physics Letters•Nov 14, 2005•161 citations

Photothermal tuning and stabilization of a photonic crystal nanofiber cavity

王杰 Wang Jie, K. P. Nayak, Jameesh Keloth

We report the photothermal properties of a photonic crystal nanofiber (PhCN) cavity, which is fabricated using a femtosecond laser ablation technique, under ultra-high vacuum conditions. The results show that by launching a non-resonant guided light, the stopband of the PhCN, along with the cavity modes, can be tuned at a rate of 250 GHz (∼0.5 nm)/mW. Moreover, due to the thermal self-locking effect of a resonant light, a cavity mode with a finesse of 25 can be tuned over a few free spectral ranges using only a few μW of guided light. As an enabling step, we demonstrate a dual-mode locking scheme to thermally stabilize a cavity mode to the atomic line for single atom-based cavity quantum electrodynamics experiments.

Optics Letters•Aug 7, 2019•6 citations

TOWARDS THE ULTIMATE OPTICAL DETECTION SENSITIVITY: NEW SPECTROSCOPIC OPPORTUNITIES- AND A ZILLION NEW WAVELENGTH/FREQUENCY STANDARDS

J. L. Hall

High sensitivity detection of quantum absorption is demonstrated at a sensitivity of $1 \\times 10^{11}$ integrated absorption, in 1 sec, using 10 mTorr total gas pressure. Achieving highly sensitive detection relies on simple basic principles: 1) The molecule-generated electric field in the forward direction (the "darkness wave") is most precious, and contains the maximum available information. It is the physical manifestation of the -$alpha^{*}$L term appearing when beer#### absorption law is expanded for low opacity, 2) After generating the molecular signal, the detected unabsorbed light sets the "shotnoise" measurement floor. We use an optical transmission cavity for the gas cell, since the high internal "build-up" field will elicit a strong molecular "darkness wave", for a given transmitted de light on the detector, A more conventional explanation of Gavity Enhancement would be the extension of the effective cell length by the factor finesse $^{*}2/\\pi.3$) To avoid excess low-frequency noise, such small signals should be measured by ac methods, comparing on-resonant and off-resonant cases in quick succession. 4) By SIMULTANEOUSLY obtaining and subtracting these cases, one provides a siginal channel with NO OUTPUT unless there is a resonance. This is conveniently accomplished by using the FM detection method with the optical heterodyne sidebands and carrier being transmitted through the cavity via adjacent axial orders 5). A remarkable property of this configuration, when the modulation frequency= cavity mode spacing, is the suppression of ANY detection of laser frequency noise with the transmitted light. We can refer to this property as (laser FM-) noise-Immune detection. This enables profitable use of cavity finesse in the range above 10,000, without a nois penalty, Altogether, we refer to this new spectroscopy as Noise-Immune, Cavity-Enhanced, Optical Heterodyne Molecular spectroscopy, i.e. "NICE OHMS". We have measured excellent saturated dispersion signals from HCCH in the band near 790 mm ($\\nu_{1} + 3 \\nu_{3}$), and recently, using a Nd:YAG source, from the HCCD P(5) line ($\\nu_{2} + 3 \\nu_{3}$) at 1064 mm. The saturation peaks broaden from the transit limit of 270 kHz near zero pressure at the rate 34.7 kHz/m Torr. We observe interesting narrow linwidths 8-fold below the transit limit, basically using optical selection of slow molecules by low power and pressure (2 mW and 2 m Torr). The absolute frequency is measurred to be 281, 635,363,960 MHz $\\pm 45$ kHz.

•Jan 1, 1996•0 citations

Light-Matter Interactions using a Nanofiber-Segment Ring Resonator

T. B. Pittman, Daniel E. Jones, Garrett Hickman +1 more

We describe experimental work on a nanofiber-based ring resonator that enables strong interactions between the cavity-enhanced field and atoms near the nanofiber surface. This “all fiber” cavity has applications in nonlinear spectroscopy and quantum optics.

Frontiers in Optics•Jan 1, 2016•0 citations
Sensitive Photothermal Gas Detection in a Fiber-Tip Cavity Selective, parts-per-billion level gas-phase chemical detection is achieved within a fiber-tip cavity by harnessing the strong light-matter interaction in a small cavity mode volume. This remarkable detection sensitivity is enabled by an innovative dual-enhanced photothermal technique. The proposed method has the potential to transform fields such as biological analysis, battery diagnostics, molecular spectroscopy in quantum electrodynamics, and the investigation of microscale processes. See article number 2400907 by Sen Yang, Wei Ren, and co-workers.
We have realized a fiber-based Fabry–Perot cavity with CO 2 laser-machined mirrors. It combines very small size, high finesse , small waist and mode volume, and good mode matching between the fiber and cavity modes. This combination of features is a major advance for cavity quantum electrodynamics (CQED), as shown in recent CQED experiments with Bose–Einstein condensates enabled by this cavity (Colombe Y et al 2007 Nature 450 272). It will also be suitable for a wide range of other applications, including coupling to solid-state emitters, gas detection at the single-particle level, fiber-coupled single-photon sources and high-resolution optical filters with large stopband.
Label-free optical sensor systems have emerged that exhibit extraordinary sensitivity for detecting physical, chemical, and biological entities at the micro/nanoscale. Particularly exciting is the detection and analysis of molecules, on miniature optical devices that have many possible applications in health, environment, and security. These micro- and nanosensors have now reached a sensitivity level that allows for the detection and analysis of even single molecules. Their small size enables an exceedingly high sensitivity, and the application of quantum optical measurement techniques can allow the classical limits of detection to be approached or surpassed. The new class of label-free micro- and nanosensors allows dynamic processes at the single-molecule level to be observed directly with light. By virtue of their small interaction length, these micro- and nanosensors probe light-matter interactions over a dynamic range often inaccessible by other optical techniques. For researchers entering this rapidly advancing field of single-molecule micro- and nanosensors, there is an urgent need for a timely review that covers the most recent developments and that identifies the most exciting opportunities. The focus here is to provide a summary of the recent techniques that have either demonstrated label-free single-molecule detection or claim single-molecule sensitivity.
We present a microfabricated optical cavity, which combines a very small mode volume with high finesse. In contrast to other micro-resonators, such as microspheres, the structure we have built gives atoms and molecules direct access to the high-intensity part of the field mode, enabling them to interact strongly with photons in the cavity for the purposes of detection and quantum-coherent manipulation. Light couples directly in and out of the resonator through an optical fiber, avoiding the need for sensitive coupling optics. This renders the cavity particularly attractive as a component of a lab-on-a-chip, and as a node in a quantum network.
We report the photothermal properties of a photonic crystal nanofiber (PhCN) cavity, which is fabricated using a femtosecond laser ablation technique, under ultra-high vacuum conditions. The results show that by launching a non-resonant guided light, the stopband of the PhCN, along with the cavity modes, can be tuned at a rate of 250 GHz (∼0.5 nm)/mW. Moreover, due to the thermal self-locking effect of a resonant light, a cavity mode with a finesse of 25 can be tuned over a few free spectral ranges using only a few μW of guided light. As an enabling step, we demonstrate a dual-mode locking scheme to thermally stabilize a cavity mode to the atomic line for single atom-based cavity quantum electrodynamics experiments.
High sensitivity detection of quantum absorption is demonstrated at a sensitivity of 1times10111 \\times 10^{11}1times1011 integrated absorption, in 1 sec, using 10 mTorr total gas pressure. Achieving highly sensitive detection relies on simple basic principles: 1) The molecule-generated electric field in the forward direction (the "darkness wave") is most precious, and contains the maximum available information. It is the physical manifestation of the -alpha∗alpha^{*}alpha∗L term appearing when beer#### absorption law is expanded for low opacity, 2) After generating the molecular signal, the detected unabsorbed light sets the "shotnoise" measurement floor. We use an optical transmission cavity for the gas cell, since the high internal "build-up" field will elicit a strong molecular "darkness wave", for a given transmitted de light on the detector, A more conventional explanation of Gavity Enhancement would be the extension of the effective cell length by the factor finesse ∗2/pi.3^{*}2/\\pi.3∗2/pi.3) To avoid excess low-frequency noise, such small signals should be measured by ac methods, comparing on-resonant and off-resonant cases in quick succession. 4) By SIMULTANEOUSLY obtaining and subtracting these cases, one provides a siginal channel with NO OUTPUT unless there is a resonance. This is conveniently accomplished by using the FM detection method with the optical heterodyne sidebands and carrier being transmitted through the cavity via adjacent axial orders 5). A remarkable property of this configuration, when the modulation frequency= cavity mode spacing, is the suppression of ANY detection of laser frequency noise with the transmitted light. We can refer to this property as (laser FM-) noise-Immune detection. This enables profitable use of cavity finesse in the range above 10,000, without a nois penalty, Altogether, we refer to this new spectroscopy as Noise-Immune, Cavity-Enhanced, Optical Heterodyne Molecular spectroscopy, i.e. "NICE OHMS". We have measured excellent saturated dispersion signals from HCCH in the band near 790 mm (nu1+3nu3\\nu_{1} + 3 \\nu_{3}nu1​+3nu3​), and recently, using a Nd:YAG source, from the HCCD P(5) line (nu2+3nu3\\nu_{2} + 3 \\nu_{3}nu2​+3nu3​) at 1064 mm. The saturation peaks broaden from the transit limit of 270 kHz near zero pressure at the rate 34.7 kHz/m Torr. We observe interesting narrow linwidths 8-fold below the transit limit, basically using optical selection of slow molecules by low power and pressure (2 mW and 2 m Torr). The absolute frequency is measurred to be 281, 635,363,960 MHz pm45\\pm 45pm45 kHz.