Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

SPIE Quantum Technologies for Defence and Security

Towards a reflective-based imaging device with undetected photons

Chiara Michelini, Ugo Zanforlin, Massimiliano Proietti, Lorenzo Pavesi, Massimiliano Dispenza

Published Nov 15, 2024• 0 citations
Publisher
DOI
10.1117/12.3031169

Related papers

Quantum imaging with undetected photons

Gabriela Barreto Lemos, Victoria Borish, Garrett D. Cole +3 more

arXiv:1401.4318•Nature•Aug 1, 2014•767 citations

Point spread function engineering for imaging with undetected photons

Emma J. Pearce, Osian Wolley, Simon Peter Mekhail +2 more

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Ultra-stable quantum imaging with undetected photons in video rate

Marta Gilaberte Basset, Josué R. León Torres, Tobias Bernd Gäbler +1 more

We report on a highly stable and portable system for quantum imaging with undetected photons in video rate. Our results will pave the way towards extreme light imaging devices for life science.

OSA Quantum 2.0 Conference•Jan 1, 2020•0 citations

Sensing with Undetected Photons

Jinghan Dong

•Aug 1, 2026•0 citations

Resolution limit in quantum imaging with undetected photons using position correlations

Balakrishnan Viswanathan, Gabriela Barreto Lemos, Mayukh Lahiri

Quantum imaging with undetected photons (QIUP) is a unique method of image acquisition where the photons illuminating the object are not detected. This method relies on quantum interference and spatial correlations between the twin photons to form an image. Here we present a detailed study of the resolution limits of position correlation enabled QIUP. We establish a quantitative relation between the spatial resolution and the twin-photon position correlation. Furthermore, we also quantitatively establish the roles that the wavelength of the undetected illumination field and the wavelength of the detected field play in the resolution. Like ghost imaging and unlike conventional imaging, the resolution limit imposed by the spatial correlation between the twin photons in QIUP cannot be further improved by conventional optical techniques.

arXiv:2106.11358•Optics Express•Oct 7, 2021•31 citations

Towards imaging with undetected photons with a nonlinear Mach-Zehnder-type interferometer in MIR

Florian G. Herbst, Florian Elsen, Bernd Jungbluth +2 more

Spontaneous parametric down-conversion can produce pairs of entangled photons with very different wavelengths. Using SPDC, the scheme of Imaging with Undetected Photons promises to be a versatile tool to facilitate imaging in various spectral ranges and various interferometer designs and geometries. Here, we tackle the task of Imaging with Undetected Photons with a Mach-Zehnder-type Interferometer in MIR. With imaging achieved in a preliminary setup, we investigate the limitations set by nonlinear conversion efficiencies, optical resolution, laser power, and fluorescence of optics on our way to Imaging with Undetected Photons in MIR.

Nonlinear Frequency Generation and Conversion: Materials and Devices•Mar 4, 2021•0 citations
Quantum imaging with undetected photons (QIUP) is a unique method of image acquisition where the photons illuminating the object are not detected. This method relies on quantum interference and spatial correlations between the twin photons to form an image. Here we present a detailed study of the resolution limits of position correlation enabled QIUP. We establish a quantitative relation between the spatial resolution and the twin-photon position correlation. Furthermore, we also quantitatively establish the roles that the wavelength of the undetected illumination field and the wavelength of the detected field play in the resolution. Like ghost imaging and unlike conventional imaging, the resolution limit imposed by the spatial correlation between the twin photons in QIUP cannot be further improved by conventional optical techniques.
Spontaneous parametric down-conversion can produce pairs of entangled photons with very different wavelengths. Using SPDC, the scheme of Imaging with Undetected Photons promises to be a versatile tool to facilitate imaging in various spectral ranges and various interferometer designs and geometries. Here, we tackle the task of Imaging with Undetected Photons with a Mach-Zehnder-type Interferometer in MIR. With imaging achieved in a preliminary setup, we investigate the limitations set by nonlinear conversion efficiencies, optical resolution, laser power, and fluorescence of optics on our way to Imaging with Undetected Photons in MIR.