Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum 2.0 Conference and Exhibition

Approaching maximal precision of Hong-Ou-Mandel interferometry with non-perfect visibility

Othmane Meskine, Éloi Descamps, Arne Keller, Aristide Lemaître, F. Baboux, S. Ducci, P. Milman

Published Jan 1, 2024• 0 citations
Publisher

Abstract

This work explores precision limits in two-photon Hong-Ou-Mandel interferometry under non-perfect visibility. A theoretical model is developed and experimentally validated. Results show a 0.97 ratio between experimental precision and the quantum limit, setting a new benchmark.
DOI
10.1364/quantum.2024.qtu3a.43

Related papers

Approaching maximal precision of Hong-Ou-Mandel interferometry with non-perfect visibility

Othmane Meskine, Éloi Descamps, Arne Keller +4 more

This work explores precision limits in two-photon Hong-Ou-Mandel interferometry under non-perfect visibility. A theoretical model is developed and experimentally validated using different quantum states. A remarkable ratio of 0.97 between the experimental precision and the quantum limit is observed, establishing a new benchmark in the field.

EPJ Web of Conferences•Jan 1, 2024•0 citations

Experimental demonstration of time measurement precision limitations in Hong-Ou-Mandel interferometry

Othmane Meskine, Éloi Descamps, Arne Keller +4 more

In quantum mechanics, the precision achieved in parameter estimation using a quantum state as a probe is determined by the measurement strategy employed. The quantum precision limit, a fundamental boundary, is defined by the intrinsic characteristics of the state and its dynamics. Theoretical results have revealed that in interference measurements with two possible outcomes, like the Hong Ou-Mandel interference, this limit can be reached under ideal conditions of perfect visibility and zero losses. However, in practice, this cannot be achieved, so precision never reaches the quantum limit. But how do experimental setups approach precision limits under realistic circumstances? In this work, we provide a general model for precision limits in two-photon Hong-Ou-Mandel interferometry for non-perfect visibility and validate it experimentally using different quantum states. A remarkable ratio of 0.97 between the experimental precision and the quantum limit is observed, establishing a new benchmark in the field.

SPIE Quantum Technologies•Jun 10, 2024•1 citation

Approaching Maximal Precision of Hong-Ou-Mandel Interferometry with Nonperfect Visibility

Othmane Meskine, Éloi Descamps, Arne Keller +4 more

In quantum mechanics, the precision achieved in parameter estimation using a quantum state as a probe is determined by the measurement strategy employed. The quantum limit of precision is bounded by a value set by the state and its dynamics. Theoretical results have revealed that in interference measurements with two possible outcomes, this limit can be reached under ideal conditions of perfect visibility and zero losses. However, in practice, these conditions cannot be achieved, so precision never reaches the quantum limit. But how do experimental setups approach precision limits under realistic circumstances? In this Letter, we provide a model for precision limits in two-photon Hong-Ou-Mandel interferometry using coincidence statistics for nonperfect visibility and temporally unresolved measurements. We show that the scaling of precision with visibility depends on the effective area in time-frequency phase space occupied by the state used as a probe, and we find that an optimal scaling exists. We demonstrate our results experimentally for different states in a setup where the visibility can be controlled and reaches up to 99.5%. In the optimal scenario, a ratio of 0.97 is observed between the experimental precision and the quantum limit, establishing a new benchmark in the field.

arXiv:2309.10633•Physical Review Letters•May 7, 2024•10 citations

Quantum metrology timing limits of the Hong-Ou-Mandel interferometer and of general two-photon measurements

Kyle M. Jordan, Raphael A. Abrahão, Jeff S. Lundeen

We examine the precision limits of Hong-Ou-Mandel (HOM) timing measurements, as well as precision limits applying to generalized two-photon measurements. As a special case we consider the use of two-photon measurements using photons with variable bandwidths and frequency correlations. When the photon bandwidths are not equal, maximizing the measurement precision involves a tradeoff between high interference visibility and strong frequency anticorrelations, with the optimal precision occurring when the photons share nonmaximal frequency anticorrelations. We show that a generalized measurement has precision limits that are qualitatively similar to those of the HOM measurement whenever the generalized measurement is insensitive to the net delay of both photons. By examining the performance of states with more general frequency distributions, our analysis allows for engineering of the joint spectral amplitude for use in realistic situations, in which both photons may not have ideal spectral properties.

arXiv:2206.11387•Physical Review A•Dec 22, 2022•22 citations

Quantum Limits in Precision Hong-Ou-Mandel Interferometry

Kyle M. Jordan, Raphael A. Abrahão, Jeff S. Lundeen

We examine the precision limits of Hong-Ou-Mandel interferometry-based timing measurements using the Cramér-Rao bounds. We show how to adapt the method for realistic sources of photon pairs involving unequal mode bandwidths and nonmaximal frequency correlations.

Quantum 2.0 Conference and Exhibition•Jan 1, 2022•0 citations

High precision metrology from the fisher information of a Hong-Ou-Mandel interferometer

Ashley Lyons, George C. Knee, Eliot Bolduc +4 more

Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations
In quantum mechanics, the precision achieved in parameter estimation using a quantum state as a probe is determined by the measurement strategy employed. The quantum precision limit, a fundamental boundary, is defined by the intrinsic characteristics of the state and its dynamics. Theoretical results have revealed that in interference measurements with two possible outcomes, like the Hong Ou-Mandel interference, this limit can be reached under ideal conditions of perfect visibility and zero losses. However, in practice, this cannot be achieved, so precision never reaches the quantum limit. But how do experimental setups approach precision limits under realistic circumstances? In this work, we provide a general model for precision limits in two-photon Hong-Ou-Mandel interferometry for non-perfect visibility and validate it experimentally using different quantum states. A remarkable ratio of 0.97 between the experimental precision and the quantum limit is observed, establishing a new benchmark in the field.
In quantum mechanics, the precision achieved in parameter estimation using a quantum state as a probe is determined by the measurement strategy employed. The quantum limit of precision is bounded by a value set by the state and its dynamics. Theoretical results have revealed that in interference measurements with two possible outcomes, this limit can be reached under ideal conditions of perfect visibility and zero losses. However, in practice, these conditions cannot be achieved, so precision never reaches the quantum limit. But how do experimental setups approach precision limits under realistic circumstances? In this Letter, we provide a model for precision limits in two-photon Hong-Ou-Mandel interferometry using coincidence statistics for nonperfect visibility and temporally unresolved measurements. We show that the scaling of precision with visibility depends on the effective area in time-frequency phase space occupied by the state used as a probe, and we find that an optimal scaling exists. We demonstrate our results experimentally for different states in a setup where the visibility can be controlled and reaches up to 99.5%. In the optimal scenario, a ratio of 0.97 is observed between the experimental precision and the quantum limit, establishing a new benchmark in the field.
We examine the precision limits of Hong-Ou-Mandel (HOM) timing measurements, as well as precision limits applying to generalized two-photon measurements. As a special case we consider the use of two-photon measurements using photons with variable bandwidths and frequency correlations. When the photon bandwidths are not equal, maximizing the measurement precision involves a tradeoff between high interference visibility and strong frequency anticorrelations, with the optimal precision occurring when the photons share nonmaximal frequency anticorrelations. We show that a generalized measurement has precision limits that are qualitatively similar to those of the HOM measurement whenever the generalized measurement is insensitive to the net delay of both photons. By examining the performance of states with more general frequency distributions, our analysis allows for engineering of the joint spectral amplitude for use in realistic situations, in which both photons may not have ideal spectral properties.
Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).