Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Progress Towards a High Data Rate Grating Magneto-Optical Trap

Roger Ding, Adrian Orozco, Peter D. D. Schwindt, Jongmin Lee

Published Jun 1, 2023• 0 citations
Publisher
DOI
10.2172/2431035

Related papers

High-Efficiency 2d Grating Design for the Magneto-Optical Trap: Enhancing Intensity Balance and Reducing Optical Complexity

Elaheh Karooby, Jiazhen Li, Amit Kumar Agrawal +1 more

•Jan 1, 2025•0 citations

Population grating decay in a magneto-optical trap

A. Lezama, George C. Cardoso, S. S. Vianna +1 more

European Quantum Electronics Conference (EQEC)•Aug 24, 2005•0 citations

High diffraction efficiency grating atom chip for magneto-optical trap

Junyi Duan, Xiaochi Liu, Yadong Zhou +7 more

Optics Communications•Feb 22, 2022•21 citations

Achieving a Stable Magneto-Optical Trap

Chasen S Himeda

•Jan 1, 2018•0 citations

A Compact, High-Data-Rate, High-Sensitivity GMOT-Based Light-Pulse Atom Interferometer toward Time-Multiplexed, Multi-Axis Inertial Sensing

Benjamin Smith, Adrian Orozco, Jongmin Lee

Light-pulse atom interferometry has emerged as a promising approach for developing quantum inertial and gravity sensors for real-world applications, but achieving robust operation in dynamic environments without sacrificing sensitivity remains challenging. To mitigate performance degradations resulting from vibration-induced noise and mismatches in the spatial overlap between free-falling atoms and light pulses, we demonstrate a first-of-a-kind high-data-rate, high-sensitivity grating magneto-optical trap (GMOT)-based light-pulse atom interferometer (LPAI). This system uses a compact, rugged GMOT architecture, based on an in-vacuum microfabricated grating chip and a single laser-cooling beam, to enable high-data-rate GMOT-based cold-atom generation with sub-Doppler cooling. Our GMOT-based LPAI operates at high data rates (up to 100 Hz), while simultaneously achieving both high acceleration sensitivity (550 ng/rt-Hz at 20 Hz, 1.49 ug/rt-Hz at 45 Hz, and 6.31 ug/rt-Hz at 70 Hz) and good bias stability (71 ng). This compact, rugged architecture paves the way for field-deployable quantum inertial and gravity sensors in high dynamics and for time-multiplexed, multi-axis inertial sensing.

arXiv:2610.01735•Oct 1, 2026•0 citations

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Jongmin Lee, Roger Ding, Justin Christensen +16 more

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. We describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. The vacuum package is integrated into the optomechanical design of a compact cold-atom sensor head with fixed optical components. In addition, a multichannel laser system driven by a single seed laser has been implemented with time-multiplexed frequency shifting using single sideband modulators, reducing the number of optical channels connected to the sensor head. This laser system architecture is compatible with a highly miniaturized photonic integrated circuit approach, and by demonstrating atom-interferometer operation with this laser system, we show feasibility for the integrated photonic approach. In the compact sensor head, sub-Doppler cooling in the GMOT produces 15 μK temperatures, which can operate at a 20 Hz data rate for the atom interferometer sequence. After validating atomic coherence with Ramsey interferometry, we demonstrate a light-pulse atom interferometer in a gravimeter configuration without vibration isolation for 10 Hz measurement cycle rate and T = 0 - 4.5 ms interrogation time, resulting in Δg/g = 2.0e-6. All these efforts demonstrate progress towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

Nature Communications•Sep 1, 2022•101 citations
Light-pulse atom interferometry has emerged as a promising approach for developing quantum inertial and gravity sensors for real-world applications, but achieving robust operation in dynamic environments without sacrificing sensitivity remains challenging. To mitigate performance degradations resulting from vibration-induced noise and mismatches in the spatial overlap between free-falling atoms and light pulses, we demonstrate a first-of-a-kind high-data-rate, high-sensitivity grating magneto-optical trap (GMOT)-based light-pulse atom interferometer (LPAI). This system uses a compact, rugged GMOT architecture, based on an in-vacuum microfabricated grating chip and a single laser-cooling beam, to enable high-data-rate GMOT-based cold-atom generation with sub-Doppler cooling. Our GMOT-based LPAI operates at high data rates (up to 100 Hz), while simultaneously achieving both high acceleration sensitivity (550 ng/rt-Hz at 20 Hz, 1.49 ug/rt-Hz at 45 Hz, and 6.31 ug/rt-Hz at 70 Hz) and good bias stability (71 ng). This compact, rugged architecture paves the way for field-deployable quantum inertial and gravity sensors in high dynamics and for time-multiplexed, multi-axis inertial sensing.
Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. We describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. The vacuum package is integrated into the optomechanical design of a compact cold-atom sensor head with fixed optical components. In addition, a multichannel laser system driven by a single seed laser has been implemented with time-multiplexed frequency shifting using single sideband modulators, reducing the number of optical channels connected to the sensor head. This laser system architecture is compatible with a highly miniaturized photonic integrated circuit approach, and by demonstrating atom-interferometer operation with this laser system, we show feasibility for the integrated photonic approach. In the compact sensor head, sub-Doppler cooling in the GMOT produces 15 μK temperatures, which can operate at a 20 Hz data rate for the atom interferometer sequence. After validating atomic coherence with Ramsey interferometry, we demonstrate a light-pulse atom interferometer in a gravimeter configuration without vibration isolation for 10 Hz measurement cycle rate and T = 0 - 4.5 ms interrogation time, resulting in Δg/g = 2.0e-6. All these efforts demonstrate progress towards deployable cold-atom inertial sensors under large amplitude motional dynamics.