Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Elsevier eBooks

Optical lattice clocks and related platforms

Masao Takamoto, Hidetoshi Katori

Published Jan 1, 2024• 0 citations
Publisher
DOI
10.1016/b978-0-323-98378-5.00002-7

Related papers

Optical lattice clocks

P. Lemonde

The European Physical Journal Special Topics•Jun 1, 2009•34 citations

Doubly Modulated Optical Lattice Clock: Interference and Topology

Xiaotong Lu, Tao Wang, Ting Li +5 more

The quantum system under periodical modulation is the simplest path to understand the quantum nonequilibrium system because it can be well described by the effective static Floquet Hamiltonian. Under the stroboscopic measurement, the initial phase is usually irrelevant. However, if two uncorrelated parameters are modulated, their relative phase cannot be gauged out so that the physics can be dramatically changed. Here, we simultaneously modulate the frequency of the lattice laser and the Rabi frequency in an optical lattice clock (OLC) system. Thanks to the ultrahigh precision and ultrastability of the OLC, the relative phase could be fine-tuned. As a smoking gun, we observed the interference between two Floquet channels. Finally, by experimentally detecting the eigenenergies, we demonstrate the relation between the effective Floquet Hamiltonian and the one-dimensional topological insulator with a high winding number. Our experiment not only provides a direction for detecting the phase effect but also paves a way in simulating the quantum topological phase in the OLC platform.

arXiv:2009.11671•Physical Review Letters•Jul 14, 2021•27 citations

Optical Lattice Clocks

Chris W. Oates

Bulletin of the American Physical Society•Jun 5, 2012•0 citations

Double Parameters Modulated Optical Lattice Clock: Interference and Topology

Xiaotong Lu, Tao Wang, Ting Li +5 more

The quantum system under periodical modulation is the simplest path to understand the quantum non-equilibrium system, because it can be well described by the effective static Floquet Hamiltonian. Under the stroboscopic measurement, the initial phase is usually irrelevant. However, if two uncorrelated parameters are modulated, their relative phase can not be gauged out, so that it can dramatically change physics. Here, we simultaneously modulate the frequency of lattice laser and Rabi frequency in the optical lattice clock (OLC) system. Thanks to ultra-high precision and ultra-stability of OLC, the relative phase could be fine-tuned. As a smoking gun, we observed the interference between two Floquet channels. At last, we discuss the relation between effective Floquet Hamiltonian and 1-D topological insulator with high winding numbers. Our experiment not only provides a direction for detecting the phase effect, but also paves a way in simulating quantum topological phase in OLC platform.

•Sep 24, 2020•0 citations

Optical lattice clocks

S. Bize

•Oct 10, 2023•0 citations

High precision differential clock comparisons with a multiplexed optical lattice clock

Xin Zheng, Jonathan Dolde, Varun Lochab +3 more

Rapid progress in the precision and accuracy of optical atomic clocks over the last decade has advanced the frontiers of timekeeping, metrology, and quantum science. However, the stabilities of most optical clocks remain limited by the local oscillator rather than the atoms themselves, leaving room for further progress. Here we implement a "multiplexed" one-dimensional optical lattice clock, in which spatially-resolved, movable ensembles of ultra-cold strontium atoms are trapped in the same optical lattice, interrogated simultaneously by a shared clock laser, and read-out in parallel. By performing synchronized Ramsey interrogations of ensemble pairs we observe atom-atom coherence times up to 26 seconds, a 270-fold improvement over the atom-laser coherence time, demonstrate a relative stability of $9.7(4)\times10^{-18}/\sqrtτ$ (where $τ$ is the averaging time in seconds), and reach a fractional uncertainty of $8.9(3)\times 10^{-20}$ after 3.3 hours of averaging. These results demonstrate that applications requiring ultra-high-precision comparisons between optical atomic clocks need not be limited by the stability of the local oscillator. With multiple ensemble pairs, we realize a miniaturized clock network consisting of 6 atom ensembles, resulting in 15 unique pairwise clock comparisons with relative stabilities below $3\times10^{-17}/\sqrtτ$. Finally, we demonstrate the capability to simultaneously load spatially-resolved, heterogeneous ensemble pairs of all four stable isotopes of strontium in a lattice. The unique capabilities offered by this platform pave the way for future studies of precision isotope shift measurements, spatially resolved characterization of limiting clock systematics, development of clock-based gravitational wave and dark matter detectors, and novel tests of relativity including measurements of the gravitational redshift at sub-centimeter scales.

arXiv:2109.12237•Sep 24, 2021•5 citations
The quantum system under periodical modulation is the simplest path to understand the quantum nonequilibrium system because it can be well described by the effective static Floquet Hamiltonian. Under the stroboscopic measurement, the initial phase is usually irrelevant. However, if two uncorrelated parameters are modulated, their relative phase cannot be gauged out so that the physics can be dramatically changed. Here, we simultaneously modulate the frequency of the lattice laser and the Rabi frequency in an optical lattice clock (OLC) system. Thanks to the ultrahigh precision and ultrastability of the OLC, the relative phase could be fine-tuned. As a smoking gun, we observed the interference between two Floquet channels. Finally, by experimentally detecting the eigenenergies, we demonstrate the relation between the effective Floquet Hamiltonian and the one-dimensional topological insulator with a high winding number. Our experiment not only provides a direction for detecting the phase effect but also paves a way in simulating the quantum topological phase in the OLC platform.
The quantum system under periodical modulation is the simplest path to understand the quantum non-equilibrium system, because it can be well described by the effective static Floquet Hamiltonian. Under the stroboscopic measurement, the initial phase is usually irrelevant. However, if two uncorrelated parameters are modulated, their relative phase can not be gauged out, so that it can dramatically change physics. Here, we simultaneously modulate the frequency of lattice laser and Rabi frequency in the optical lattice clock (OLC) system. Thanks to ultra-high precision and ultra-stability of OLC, the relative phase could be fine-tuned. As a smoking gun, we observed the interference between two Floquet channels. At last, we discuss the relation between effective Floquet Hamiltonian and 1-D topological insulator with high winding numbers. Our experiment not only provides a direction for detecting the phase effect, but also paves a way in simulating quantum topological phase in OLC platform.
Rapid progress in the precision and accuracy of optical atomic clocks over the last decade has advanced the frontiers of timekeeping, metrology, and quantum science. However, the stabilities of most optical clocks remain limited by the local oscillator rather than the atoms themselves, leaving room for further progress. Here we implement a "multiplexed" one-dimensional optical lattice clock, in which spatially-resolved, movable ensembles of ultra-cold strontium atoms are trapped in the same optical lattice, interrogated simultaneously by a shared clock laser, and read-out in parallel. By performing synchronized Ramsey interrogations of ensemble pairs we observe atom-atom coherence times up to 26 seconds, a 270-fold improvement over the atom-laser coherence time, demonstrate a relative stability of 9.7(4)×10−18/τ9.7(4)\times10^{-18}/\sqrtτ9.7(4)×10−18/τ​ (where τττ is the averaging time in seconds), and reach a fractional uncertainty of 8.9(3)×10−208.9(3)\times 10^{-20}8.9(3)×10−20 after 3.3 hours of averaging. These results demonstrate that applications requiring ultra-high-precision comparisons between optical atomic clocks need not be limited by the stability of the local oscillator. With multiple ensemble pairs, we realize a miniaturized clock network consisting of 6 atom ensembles, resulting in 15 unique pairwise clock comparisons with relative stabilities below 3×10−17/τ3\times10^{-17}/\sqrtτ3×10−17/τ​. Finally, we demonstrate the capability to simultaneously load spatially-resolved, heterogeneous ensemble pairs of all four stable isotopes of strontium in a lattice. The unique capabilities offered by this platform pave the way for future studies of precision isotope shift measurements, spatially resolved characterization of limiting clock systematics, development of clock-based gravitational wave and dark matter detectors, and novel tests of relativity including measurements of the gravitational redshift at sub-centimeter scales.