Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI

Dual polarization kinetic inductance detectors for large imaging cameras at millimeter wave bands

E. Artal, B. Aja, Luisa de la Fuente, Juan Pablo Pascual Gutiérrez, Enrique Villa, Marina C. de Ory, David Rodríguez, Víctor Rollano, Maite Magaz, A. Gómez, Daniel Granados

Published Jun 14, 2024• 0 citations
Publisher

Abstract

This work deals with the development of superconducting Kinetic Inductance Detectors (KIDs) for highly sensitive radio astronomy receivers within W-band (75 to 110 GHz). A bilayer based on superconducting titanium/aluminum (Ti/Al) thin films has been used for assessing its absorption performance in this frequency band at millikelvin temperature. A lumped-element inductor based on a 4th order Hilbert structure is designed to absorb the incoming radiation in two orthogonal linear polarizations. The development of a large-format camera prototype is presented. On one hand, ambient temperature quasi-optical characterization demonstrates a suitable absorption for both polarizations within the W-band. On the other hand, dark cryogenic characterization confirms the successful operation of the multiplexed KID devices providing high-quality factors and an operation yield of 97%. These results confirm these developments to be used in future polarimeter receivers.

DOI
10.1117/12.3014677

Related papers

Analysis and Performance of Lumped-Element Kinetic Inductance Detectors for W-Band

B. Aja, Marina C. de Ory, Luisa de la Fuente +5 more

Lumped-element superconducting resonators are a promising technology for their use in millimeter-wave observations and quantum computing applications that require large arrays of extremely sensitive detectors. Among them, lumped-element kinetic inductance detectors (LEKIDs) have shown good performance in the submillimeter band in several earth-based telescopes. In this work, LEKIDs for their use as millimeter-wave receivers of astronomical applications are presented. LEKID arrays using a thin bilayer of superconducting titanium/aluminum (Ti/Al), deposited on the silicon substrate, have been designed and fabricated. The design of a dual-polarization LEKID with the goal of detection at the W-band for two orthogonal polarizations is described and a fabricated array has demonstrated absorption at ambient temperature. Also, an approximate design methodology of the coupling parameter for LEKIDs' readout, essential for dynamic range optimization of the detector under millimeter-wave radiation, is proposed. In addition, the resonance characteristics and coupling factor of the fabricated superconducting resonators using high-quality internal factor Qiunder cryogenic temperatures have been analyzed. The design guidelines in this work are applicable to other LEKID arrays, and the presented superconducting Ti/Al thin-film LEKIDs can be used in future receiver arrays in the millimeter bands.

IEEE Transactions on Microwave Theory and Techniques•Dec 3, 2020•10 citations

Bi-Layer Kinetic Inductance Detectors for W-Band

B. Aja, Luisa de la Fuente, A. Fernandez +7 more

An array of superconducting kinetic inductance detectors (KID) has been fabricated and it has demonstrated absorption at W-Band. The use of a bi-layer structure based on aluminum (AI) and titanium (Ti) shows a lower superconducting critical temperature (Tc), which allows the detection at W-band. A design methodology is presented taking into account the KID geometry in order to maximize the absorption and a dual-polarization KID has been designed using the proposed methodology. Two prototypes of KID on Silicon substrate have been fabricated showing a good agreement between measurement and simulation results. The measurements at room temperature from 65 to 110 GHz show the matching at the frequency band, while dark cryogenic characterization demonstrated the low frequency design.

IEEE MTT-S International Microwave Symposium digest•Aug 1, 2020•12 citations

High Sensitivity W-Band LEKID-Based on-Chip Polarimeter

Marina C. de Ory, Víctor Rollano, Martino Calvo +11 more

We have developed and characterized an on-chip polarimeter based on Lumped Element Kinetic Inductance Detectors (LEKIDs) optimized for the whole W -band frequency range ($\mathbf{7 5 - 1 1 0} \mathbf{G H z}$). The chip consists of two$\mathbf{3} \times \mathbf{3}$LEKID arrays fabricated on opposing faces of a silicon substrate. Both arrays have been fabricated from a titanium/aluminum superconducting bilayer and they present orthogonal inductor orientations to resolve horizontal and vertical polarization modes. A second silicon substrate is coated at its rear part with an aluminum thin film and works as a back-reflector to enhance the forward absorption efficiency via constructive interference. In this work, we report the absorption response and performances in the$W$band of this on-chip polarimeter configuration in both polarizations at cryogenic temperatures. The noise spectrum and the noise equivalent power (NEP) is also characterized using a blackbody source at two different temperatures to demonstrate its functionality.

IEEE MTT-S International Microwave Symposium digest•Jun 15, 2025•1 citation

Antenna-coupled lumped-element ALD titanium nitride KIDs for CMB instruments (Conference Presentation)

Erik D. Shirokoff, Peter S. Barry, Q. Y. Tang +1 more

Future ground-based cosmic microwave background (CMB) experiments will require more than $10^5$ polarization sensitive pixels covering multiple atmospheric bands. The scientific potential for such an experiment is impressive; however, the technical challenges are daunting: such an instrument will require square meters of focal plane covered in background limited cryogenic detectors and a dramatic increase in readout capability. We are developing novel kinetic inductance detectors (KIDs) optimized for this purpose. These devices use a twin-slot microwave antenna, superconducting Nb transmission line, and a novel coupling scheme that deposits mm-wavelength power onto a high-resistivity meander deposited as the first layer on a bare Si wafer. This architecture allows us to independently adjust the detector and antenna properties and to pursue multi-band designs. We have fabricated superconducting resonators made from atomic layer deposited (ALD) titanium nitride (TiN), with thicknesses ranging from 3 to 40 nm. We find a strong dependence of transition temperature on thickness, from 0.6 to 4.2 K for our thinnest and thickest films, respectively. In dark measurements, we find internal quality factors that range from $10^4$ to $7\times 10^5$ depending on film thickness, and kinetic inductance as high as 8 nH/square. The very small volumes and high kinetic inductance make it possible to engineer extremely sensitive detectors with inductor volumes approaching a few cubic microns that operate at readout frequencies of tens to hundreds of MHz. By taking advantage of the large fractional bandwidth available at low frequencies, we expect to achieve multiplexing densities that exceed that of state of the art TES arrays even without further improvements in film quality factor. We will present the characterization of film properties and dark devices, as well as well as initial optical results for antenna coupled single-band and single-pol devices. We will also discuss designs and sensitivity projections for future dual-pol and multi-band arrays ready for deployment in near-future CMB instruments.

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI•Jul 10, 2018•0 citations

Kinetic inductance detectors for 200μm astronomy

Simon M. Doyle, Jack Alexander Naylon, James Cox +2 more

Kinetic inductance detectors (KIDs) provide an attractive solution to the production of large detector arrays for use in ground and space based 200μm astronomy. KIDs work by measuring the change in quasi-particle density upon photon absorption in a high Q superconducting resonator. A change in quasi-particle density is measured by a shift in phase of a microwave probe signal of frequency equal to that of the resonant frequency of the KID. Such detectors have a fundamental noise limit owing to the quasi-particle recombination rate, which, in a KID fabricated from a high quality Niobium film can give sensitivities of 10-18W√Hz at 1K. Constructing KIDs of varying resonant frequencies coupled to a single transmission line provides a multiplexed detector array with simple low temperature electronics. Here we discuss the theoretical requirements for both ground and space based 200μm cameras with various radiation coupling schemes for this wavelength range using distributed and lumped element high Q resonators.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 14, 2006•4 citations

Design and Performance of the Antenna-Coupled Lumped-Element Kinetic Inductance Detector

Peter S. Barry, S. Doyle, Amber L. Hornsby +6 more

Focal plane arrays consisting of low-noise, polarisation-sensitive detectors have made possible the pioneering advances in the study of the cosmic microwave background (CMB). To make further progress, the next generation of CMB experiments (e.g. CMB-S4) will require a substantial increase in the number of detectors compared to current instruments. Arrays of kinetic inductance detectors (KIDs) provide a possible path to realising such large-format arrays owing to their intrinsic multiplexing advantage and relative cryogenic simplicity. In this paper, we report on the design of a variant of the traditional KID design: the antenna-coupled lumped-element KID. A polarisation-sensitive twin-slot antenna placed behind an optimised hemispherical lens couples power onto a thin-film superconducting microstrip line. The power is then guided into the inductive section of an aluminium KID, where it is absorbed and modifies both the resonant frequency and quality factor of the KID. We present the various aspects of the design and preliminary results from the first set of seven-element prototype arrays and compare to the expected modelled performance.

arXiv:1801.06265•Journal of Low Temperature Physics•May 11, 2018•10 citations
This work deals with the development of superconducting Kinetic Inductance Detectors (KIDs) for highly sensitive radio astronomy receivers within W-band (75 to 110 GHz). A bilayer based on superconducting titanium/aluminum (Ti/Al) thin films has been used for assessing its absorption performance in this frequency band at millikelvin temperature. A lumped-element inductor based on a 4th order Hilbert structure is designed to absorb the incoming radiation in two orthogonal linear polarizations. The development of a large-format camera prototype is presented. On one hand, ambient temperature quasi-optical characterization demonstrates a suitable absorption for both polarizations within the W-band. On the other hand, dark cryogenic characterization confirms the successful operation of the multiplexed KID devices providing high-quality factors and an operation yield of 97%. These results confirm these developments to be used in future polarimeter receivers.
Lumped-element superconducting resonators are a promising technology for their use in millimeter-wave observations and quantum computing applications that require large arrays of extremely sensitive detectors. Among them, lumped-element kinetic inductance detectors (LEKIDs) have shown good performance in the submillimeter band in several earth-based telescopes. In this work, LEKIDs for their use as millimeter-wave receivers of astronomical applications are presented. LEKID arrays using a thin bilayer of superconducting titanium/aluminum (Ti/Al), deposited on the silicon substrate, have been designed and fabricated. The design of a dual-polarization LEKID with the goal of detection at the W-band for two orthogonal polarizations is described and a fabricated array has demonstrated absorption at ambient temperature. Also, an approximate design methodology of the coupling parameter for LEKIDs' readout, essential for dynamic range optimization of the detector under millimeter-wave radiation, is proposed. In addition, the resonance characteristics and coupling factor of the fabricated superconducting resonators using high-quality internal factor Qiunder cryogenic temperatures have been analyzed. The design guidelines in this work are applicable to other LEKID arrays, and the presented superconducting Ti/Al thin-film LEKIDs can be used in future receiver arrays in the millimeter bands.
An array of superconducting kinetic inductance detectors (KID) has been fabricated and it has demonstrated absorption at W-Band. The use of a bi-layer structure based on aluminum (AI) and titanium (Ti) shows a lower superconducting critical temperature (Tc), which allows the detection at W-band. A design methodology is presented taking into account the KID geometry in order to maximize the absorption and a dual-polarization KID has been designed using the proposed methodology. Two prototypes of KID on Silicon substrate have been fabricated showing a good agreement between measurement and simulation results. The measurements at room temperature from 65 to 110 GHz show the matching at the frequency band, while dark cryogenic characterization demonstrated the low frequency design.
We have developed and characterized an on-chip polarimeter based on Lumped Element Kinetic Inductance Detectors (LEKIDs) optimized for the whole W -band frequency range (75−110GHz\mathbf{7 5 - 1 1 0} \mathbf{G H z}75−110GHz). The chip consists of two3×3\mathbf{3} \times \mathbf{3}3×3LEKID arrays fabricated on opposing faces of a silicon substrate. Both arrays have been fabricated from a titanium/aluminum superconducting bilayer and they present orthogonal inductor orientations to resolve horizontal and vertical polarization modes. A second silicon substrate is coated at its rear part with an aluminum thin film and works as a back-reflector to enhance the forward absorption efficiency via constructive interference. In this work, we report the absorption response and performances in theWWWband of this on-chip polarimeter configuration in both polarizations at cryogenic temperatures. The noise spectrum and the noise equivalent power (NEP) is also characterized using a blackbody source at two different temperatures to demonstrate its functionality.
Future ground-based cosmic microwave background (CMB) experiments will require more than 10510^5105 polarization sensitive pixels covering multiple atmospheric bands. The scientific potential for such an experiment is impressive; however, the technical challenges are daunting: such an instrument will require square meters of focal plane covered in background limited cryogenic detectors and a dramatic increase in readout capability. We are developing novel kinetic inductance detectors (KIDs) optimized for this purpose. These devices use a twin-slot microwave antenna, superconducting Nb transmission line, and a novel coupling scheme that deposits mm-wavelength power onto a high-resistivity meander deposited as the first layer on a bare Si wafer. This architecture allows us to independently adjust the detector and antenna properties and to pursue multi-band designs. We have fabricated superconducting resonators made from atomic layer deposited (ALD) titanium nitride (TiN), with thicknesses ranging from 3 to 40 nm. We find a strong dependence of transition temperature on thickness, from 0.6 to 4.2 K for our thinnest and thickest films, respectively. In dark measurements, we find internal quality factors that range from 10410^4104 to 7×1057\times 10^57×105 depending on film thickness, and kinetic inductance as high as 8 nH/square. The very small volumes and high kinetic inductance make it possible to engineer extremely sensitive detectors with inductor volumes approaching a few cubic microns that operate at readout frequencies of tens to hundreds of MHz. By taking advantage of the large fractional bandwidth available at low frequencies, we expect to achieve multiplexing densities that exceed that of state of the art TES arrays even without further improvements in film quality factor. We will present the characterization of film properties and dark devices, as well as well as initial optical results for antenna coupled single-band and single-pol devices. We will also discuss designs and sensitivity projections for future dual-pol and multi-band arrays ready for deployment in near-future CMB instruments.
Kinetic inductance detectors (KIDs) provide an attractive solution to the production of large detector arrays for use in ground and space based 200μm astronomy. KIDs work by measuring the change in quasi-particle density upon photon absorption in a high Q superconducting resonator. A change in quasi-particle density is measured by a shift in phase of a microwave probe signal of frequency equal to that of the resonant frequency of the KID. Such detectors have a fundamental noise limit owing to the quasi-particle recombination rate, which, in a KID fabricated from a high quality Niobium film can give sensitivities of 10-18W√Hz at 1K. Constructing KIDs of varying resonant frequencies coupled to a single transmission line provides a multiplexed detector array with simple low temperature electronics. Here we discuss the theoretical requirements for both ground and space based 200μm cameras with various radiation coupling schemes for this wavelength range using distributed and lumped element high Q resonators.
Focal plane arrays consisting of low-noise, polarisation-sensitive detectors have made possible the pioneering advances in the study of the cosmic microwave background (CMB). To make further progress, the next generation of CMB experiments (e.g. CMB-S4) will require a substantial increase in the number of detectors compared to current instruments. Arrays of kinetic inductance detectors (KIDs) provide a possible path to realising such large-format arrays owing to their intrinsic multiplexing advantage and relative cryogenic simplicity. In this paper, we report on the design of a variant of the traditional KID design: the antenna-coupled lumped-element KID. A polarisation-sensitive twin-slot antenna placed behind an optimised hemispherical lens couples power onto a thin-film superconducting microstrip line. The power is then guided into the inductive section of an aluminium KID, where it is absorbed and modifies both the resonant frequency and quality factor of the KID. We present the various aspects of the design and preliminary results from the first set of seven-element prototype arrays and compare to the expected modelled performance.