Quantum synchronization has been a central topic in quantum nonlinear dynamics. Despite the rapid development in this field, very few have studied how to efficiently boost synchronization. Homodyne measurement emerges as one of the successful candidates for this task but preferably in the semiclassical regime. In our work, we focus on the phase synchronization of a harmonic-driven quantum Stuart-Landau oscillator and show that the enhancement induced by homodyne measurement persists into the quantum regime. Interestingly, optimal two-photon damping rates exist when the oscillator and driving are at resonance and with a small single-photon damping rate. We also report noise-induced enhancement in quantum synchronization when the single-photon damping rate is sufficiently large. Apart from these results, we discover that adding a squeezing Hamiltonian can further boost synchronization, especially in the semiclassical regime. Furthermore, the addition of squeezing causes the optimal two-photon pumping rates to shift and converge.
The prequel to this work [Ng et al., Phys. Rev. A 93, 042121 (2016)] proposes the method of spectral photon counting to enhance noise spectroscopy with an optical interferometer. While the predicted enhancement over homodyne detection is promising, the results there are derived by taking an asymptotic limit of infinite observation time; their validity for a finite time remains unclear. To validate the theory, here we perform a numerical study of a finite-time model. Assuming that the signal is an Ornstein--Uhlenbeck process with an unknown variance parameter, we evaluate the Fisher information for homodyne detection, a lower bound on the Fisher information for spectral photon counting, and a quantum upper bound, all without taking the infinite-time limit. To confirm that the Fisher-information quantities are satisfactory precision measures, we also compute the errors of the maximum-likelihood estimator by Monte-Carlo simulations. The results demonstrate that the Fisher-information quantities and the estimation errors all smoothly approach their asymptotic limits, and the advantage of spectral photon counting over homodyne detection can remain substantial for finite times.
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.