Tomography of Detectors Taking Dead Time into Account

Yu. I. Bogdanov, Konstantin G. Katamadze, N. A. Borshchevskaya, G. V. Avosopiants, Nadezhda A. Bogdanova, S. P. Kulik, Vladimir F. Lukichev

Published Jul 1, 2023• 0 citations
Publisher

Abstract

Using numerical simulation methods that take into account the dead time effect, algorithms are developed to calculate the detector’s response for photon fluxes with different photon number distributions, including the Poisson, Fock, and thermal distributions. Based on the results obtained, a detector tomography method is developed, as well as an algorithm for identifying the corresponding elements of a positive opera-tor-valued measure (POVM). Experimental studies using coherent states demonstrate close agreement between the calculation results and experimental data.

DOI
10.31857/s0544126923700369

Related papers

Tomography of Detectors Taking Dead Time into Account

Yu. I. Bogdanov, Konstantin G. Katamadze, N. A. Borshchevskaya +4 more

Abstract Using numerical simulation methods that take into account the dead time effect, algorithms are developed to calculate the detector’s response for photon fluxes with different photon number distributions, including the Poisson, Fock, and thermal distributions. Based on the results obtained, a detector tomography method is developed, as well as an algorithm for identifying the corresponding elements of a positive operator-valued measure (POVM). Experimental studies using coherent states demonstrate close agreement between the calculation results and experimental data.

Russian Microelectronics•Aug 1, 2023•3 citations

Tomography of spatial mode detectors

I. B. Bobrov, E. V. Kovlakov, A. A. Markov +2 more

Transformation and detection of photons in higher-order spatial modes usually requires complicated holographic techniques. Detectors based on spatial holograms suffer from non-idealities and should be carefully calibrated. We report a novel method for analyzing the quality of projective measurements in spatial mode basis inspired by quantum detector tomography. It allows us to calibrate the detector response using only gaussian beams. We experimentally investigate the inherent inaccuracy of the existing methods of mode transformation and provide a full statistical reconstruction of the POVM (positive operator valued measure) elements for holographic spatial mode detectors.

arXiv:1410.6925•Optics Express•Jan 12, 2015•9 citations

Quantum tomography of a photon-number-resolving detector based on continuous time multiplexing: memory effect

G. V. Avosopiants, Konstantin G. Katamadze, N. A. Borshchevskaya +2 more

Abstract We address the characterization of a photon-number-resolving detector based on continuous time multiplexing. We develop and verify a mathematical model of this detector and explore various approaches to its quantum tomography. Additionally, we encounter a memory effect and discuss the feasibility of describing this type of detector using a transfer matrix or positive operator-valued measure (POVM) decomposition.

Laser Physics Letters•Aug 21, 2024•1 citation

Optimized detector tomography for photon-number-resolving detectors with hundreds of pixels

D. Liu, Jia-Qi Wang, Chang‐Ling Zou +2 more

Photon-number-resolving detectors with hundreds of pixels are now readily available, while the characterization of these detectors using detector tomography is computationally intensive. Here, we present a modified detector tomography model that reduces the number of variables that need optimization. To evaluate the effectiveness and accuracy of our model, we reconstruct the photon number distribution of optical coherent and thermal states using the expectation-maximization-entropy algorithm. Our results indicate that the fidelity of the reconstructed states remains above 99%, and the second- and third-order correlations agree well with the theoretical values for a mean number of photons up to 100. We also investigate the computational resources required for detector tomography and find out that our approach reduces the solving time by around half compared to the standard detector tomography approach, and the required memory resources are the main obstacle for detector tomography of a large number of pixels. Our results suggest that detector tomography is viable on a supercomputer with 1 TB RAM for detectors with up to 340 pixels.

arXiv:2306.12622•Physical Review A•Nov 20, 2023•5 citations

Time-dependent POVM reconstruction for single-photon avalanche photo diodes using adaptive regularization

Erik Fitzke, Robin Krebs, Thorsten Haase +3 more

Abstract We report on the first realization of time-dependent quantum detector tomography for commercially available InGaAs avalanche photo detectors. For the construction of appropriate time-dependent POVMs from experimentally measured data, we introduce a novel scheme to calculate the weight of the regularization term based on the amount of measured data. We compare our POVM-based results with the theoretical predictions of the previously developed model by Gouzien et al.. In contrast to our measurement-based construction of a time-dependent POVM for photon detectors, this previous investigation extends a time-independent POVM to a time-dependent one by including effects of detector timing jitter and dead time on the basis of particular model assumptions concerning the inner physical mechanisms of a photon detector. Our experimental results demonstrate that this latter approach is not sufficient to completely describe the observable properties of our InGaAs avalanche photo detectors. Thus, constructing the time-dependent POVM of a detector by direct quantum tomographic measurements can reveal information about the detector's interior that may not easily be included in time-independent POVMs by a priori model assumptions.

arXiv:2110.10484•New Journal of Physics•Jan 28, 2022•5 citations

Tomography of Optical Quantum States with Imperfect Photon-Number-Resolving Detectors

I. A. Dmitriev, I. K. Golyshev, N. A. Bogdanova +2 more

Abstract A method for quantum state estimation using nonideal photon detection devices has been developed. Using the example of squeezed coherent states, we study the influence of detector efficiency and “dead time” on the fidelity of quantum-state reconstruction for photon-number-resolving (PNR) detectors.

Russian Microelectronics•Dec 1, 2025•0 citations
Using numerical simulation methods that take into account the dead time effect, algorithms are developed to calculate the detector’s response for photon fluxes with different photon number distributions, including the Poisson, Fock, and thermal distributions. Based on the results obtained, a detector tomography method is developed, as well as an algorithm for identifying the corresponding elements of a positive opera-tor-valued measure (POVM). Experimental studies using coherent states demonstrate close agreement between the calculation results and experimental data.
Abstract Using numerical simulation methods that take into account the dead time effect, algorithms are developed to calculate the detector’s response for photon fluxes with different photon number distributions, including the Poisson, Fock, and thermal distributions. Based on the results obtained, a detector tomography method is developed, as well as an algorithm for identifying the corresponding elements of a positive operator-valued measure (POVM). Experimental studies using coherent states demonstrate close agreement between the calculation results and experimental data.
Transformation and detection of photons in higher-order spatial modes usually requires complicated holographic techniques. Detectors based on spatial holograms suffer from non-idealities and should be carefully calibrated. We report a novel method for analyzing the quality of projective measurements in spatial mode basis inspired by quantum detector tomography. It allows us to calibrate the detector response using only gaussian beams. We experimentally investigate the inherent inaccuracy of the existing methods of mode transformation and provide a full statistical reconstruction of the POVM (positive operator valued measure) elements for holographic spatial mode detectors.
Photon-number-resolving detectors with hundreds of pixels are now readily available, while the characterization of these detectors using detector tomography is computationally intensive. Here, we present a modified detector tomography model that reduces the number of variables that need optimization. To evaluate the effectiveness and accuracy of our model, we reconstruct the photon number distribution of optical coherent and thermal states using the expectation-maximization-entropy algorithm. Our results indicate that the fidelity of the reconstructed states remains above 99%, and the second- and third-order correlations agree well with the theoretical values for a mean number of photons up to 100. We also investigate the computational resources required for detector tomography and find out that our approach reduces the solving time by around half compared to the standard detector tomography approach, and the required memory resources are the main obstacle for detector tomography of a large number of pixels. Our results suggest that detector tomography is viable on a supercomputer with 1 TB RAM for detectors with up to 340 pixels.
Abstract We report on the first realization of time-dependent quantum detector tomography for commercially available InGaAs avalanche photo detectors. For the construction of appropriate time-dependent POVMs from experimentally measured data, we introduce a novel scheme to calculate the weight of the regularization term based on the amount of measured data. We compare our POVM-based results with the theoretical predictions of the previously developed model by Gouzien et al.. In contrast to our measurement-based construction of a time-dependent POVM for photon detectors, this previous investigation extends a time-independent POVM to a time-dependent one by including effects of detector timing jitter and dead time on the basis of particular model assumptions concerning the inner physical mechanisms of a photon detector. Our experimental results demonstrate that this latter approach is not sufficient to completely describe the observable properties of our InGaAs avalanche photo detectors. Thus, constructing the time-dependent POVM of a detector by direct quantum tomographic measurements can reveal information about the detector's interior that may not easily be included in time-independent POVMs by a priori model assumptions.