Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Photonics Research

Picotesla fiberized diamond-based AC magnetometer

Shao-Chun Zhang, Yong Liu, Long‐Kun Shan, Xuedong Gao, Jiaqi Geng, Yu Cui, Yang Dong, Xiang-Dong Chen, Guang‐Can Guo, Fang‐Wen Sun

Published Mar 29, 2024• 10 citations
Publisher

Abstract

Portable quantum sensors are crucial for developing practical quantum sensing and metrology applications. Fiberized nitrogen-vacancy (NV) centers in diamonds have emerged as one of the most promising candidates for compact quantum sensors. Nevertheless, due to the difficulty of coherently controlling the ensemble spin and noise suppression in a large volume, it often faces problems such as reduced sensitivity and narrowed bandwidth in integrated lensless applications. Here, we propose a fluorescence signal treatment method for NV spin ensemble manipulation by the exponential fitting of spin polarization processes, instead of integrating the photon emission. This enables spin state readout with a high signal-to-noise ratio and applies to the pulse sensing protocols for large-volume NV spins. Based on this, we further developed a fiberized diamond-based AC magnetometer. With an XY8-N dynamical decoupling pulse sequence, we demonstrated a T2-limited sensitivity of 8 pT/Hz and T1-limited frequency resolution of 90 Hz over a wide frequency band from 100 kHz to 3 MHz. This integrated diamond sensor leverages quantum coherence to achieve enhanced sensitivity in detecting AC magnetic fields, making it suitable for implementation in a compact and portable endoscopic sensor.

DOI
10.1364/prj.522062

Related papers

Miniaturized magnetic-field sensor based on nitrogen-vacancy centers

Sigfrid Lindén Johansson, Dennis Lönard, Isabel Cardoso Barbosa +3 more

The nitrogen-vacancy (NV) center in diamond is a prime candidate for quantum sensing technologies. Here, we present a fully integrated and mechanically robust fiber-based endoscopic sensor with a tip diameter of 1.25 mm . On its tip, a direct laser-writing process is used to secure a diamond containing NV centers above the fiber’s core inside a polymer structure. Additionally, a metallic direct laser-written antenna structure next to the fiber facet allows efficient microwave manipulation of NV-center spins. The sensor achieves a shot-noise-limited magnetic-field sensitivity of 5.9 nT / Hz using a 15 − μ m -sized microdiamond at a microwave power of 50 mW and an optical power of 2.15 mW . Using lock-in techniques, we measure a sensitivity of 51.8 nT / Hz . Furthermore, we introduce a dual-fiber concept that enables, in combination with a direct laser-written structure, independent guiding of excitation and fluorescence light and thus reduces background autofluorescence. Moreover, controlled guiding of excitation light to the diamond while avoiding sample illumination may enable operation in light-sensitive environments such as biological tissue. While the demonstrated sensitivity is achieved using a single-fiber configuration, the dual-fiber approach provides a path toward integrating smaller diamonds, where autofluorescence would otherwise limit performance. We demonstrate the capability of vector magnetic-field measurements in the type of magnetic field used in state-of-the-art ultracold quantum gas experiments, opening a potential arena in which high resolution and high sensitivity are required.

arXiv:2402.19372•Physical Review Applied•Oct 24, 2025•9 citations

Enhanced Quantum Magnetometry with a Femtosecond Laser-Written Integrated Photonic Diamond Chip

Yanzhao Guo, Giulio Coccia, Vinaya K. Kavatamane +8 more

High Resolution Image Download MS PowerPoint Slide Ensemble negatively charged nitrogen-vacancy centers in diamond are promising quantum sensors. To optimize their sensitivity, it is crucial to increase the number of spins sampled and maximize their coupling to the detection system without degrading their spin properties. In this paper, we demonstrate enhanced quantum magnetometry via a buried laser-written waveguide in diamond with 4.5 ppm nitrogen-vacancy centers. The waveguide-coupled nitrogen-vacancy centers exhibit spin coherence properties comparable to those of nitrogen-vacancy centers in pristine diamond. Waveguide-enhanced magnetic field sensing is demonstrated in a fiber-coupled integrated photonic chip, where probing an increased volume of high-density spins results in 63 pT·Hz –1/2 of DC magnetic field sensitivity and 20 pT·Hz –1/2 of AC magnetic field sensitivity. This on-chip sensor realizes at least an order of magnitude improvement in sensitivity compared to the conventional confocal detection setup, paving the way for high-sensitivity quantum magnetometry with nitrogen-vacancy ensembles.

arXiv:2502.02478•Nano Letters•Apr 21, 2025•13 citations

Integrated and Endoscopic NV-Based Quantum Magnetometer

Johannes Wesseler, Roland Nagy

AbstractNitrogen-vacancy (NV) centers in diamond show disruptive potential in quantum sensing, enabling groundbreaking applications in nanoscale microscopy [1] and single-cell imaging [2]. They also promise insight into processes in complex electrochemical systems such as batteries [3]. However, most successes in these applications remain bound to laboratory conditions.We present a novel architecture for an endoscopic and fully fiber-coupled quantum magnetometer. Our sensor features a 5 mm diameter head with a micro-lens optical front-end for efficient optical excitation and fluorescence collection. An FPGA integrates the control and readout functionalities, including microwave synthesis and lock-in demodulation. This highly integrated platform achieves a magnetic field sensitivity of 150 pT/√Hz, presenting a performance record for endoscopic CW-ODMR based NV-based sensors. We verify the sensor's practical utility by performing 2D magnetic field scans of a commercial battery, demonstrating its capability in a real application scenario. This work marks a significant advance in the transition of endoscopic quantum sensors from the lab to the field.

•Mar 19, 2026•0 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation

Extending coherence time of macro-scale diamond magnetometer by dynamical decoupling with coplanar waveguide resonator

Y. MASUYAMA, Kosuke Mizuno, Hayato Ozawa +5 more

Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.

arXiv:1805.10725•Review of Scientific Instruments•Dec 1, 2018•34 citations

Quantum Logic Enhanced Sensing in Solid-State Spin Ensembles

Nithya Arunkumar, Kevin Olsson, Jner Tzern Oon +7 more

We demonstrate quantum logic enhanced sensitivity for a macroscopic ensemble of solid-state, hybrid two-qubit sensors. We achieve over a factor of 30 improvement in the single-shot signal-to-noise ratio, translating to an ac magnetic field sensitivity enhancement exceeding an order of magnitude for time-averaged measurements. Using the electronic spins of nitrogen vacancy (NV) centers in diamond as sensors, we leverage the on-site nitrogen nuclear spins of the NV centers as memory qubits, in combination with homogeneous and stable bias and control fields, ensuring that all of the ∼10^{9} two-qubit sensors are sufficiently identical to permit global control of the NV ensemble spin states. We find quantum logic sensitivity enhancement for multiple measurement protocols with varying optimal sensing intervals, including XY8 and DROID-60 dynamical decoupling, as well as correlation spectroscopy, using an applied ac magnetic field signal. The results are independent of the nature of the target signal and broadly applicable to measurements using NV centers and other solid-state spin ensembles. This work provides a benchmark for macroscopic ensembles of quantum sensors that employ quantum logic or quantum error correction algorithms for enhanced sensitivity.

arXiv:2203.12501•Physical Review Letters•Sep 5, 2023•42 citations
Portable quantum sensors are crucial for developing practical quantum sensing and metrology applications. Fiberized nitrogen-vacancy (NV) centers in diamonds have emerged as one of the most promising candidates for compact quantum sensors. Nevertheless, due to the difficulty of coherently controlling the ensemble spin and noise suppression in a large volume, it often faces problems such as reduced sensitivity and narrowed bandwidth in integrated lensless applications. Here, we propose a fluorescence signal treatment method for NV spin ensemble manipulation by the exponential fitting of spin polarization processes, instead of integrating the photon emission. This enables spin state readout with a high signal-to-noise ratio and applies to the pulse sensing protocols for large-volume NV spins. Based on this, we further developed a fiberized diamond-based AC magnetometer. With an XY8-N dynamical decoupling pulse sequence, we demonstrated a T2-limited sensitivity of 8 pT/Hz and T1-limited frequency resolution of 90 Hz over a wide frequency band from 100 kHz to 3 MHz. This integrated diamond sensor leverages quantum coherence to achieve enhanced sensitivity in detecting AC magnetic fields, making it suitable for implementation in a compact and portable endoscopic sensor.
The nitrogen-vacancy (NV) center in diamond is a prime candidate for quantum sensing technologies. Here, we present a fully integrated and mechanically robust fiber-based endoscopic sensor with a tip diameter of 1.25 mm . On its tip, a direct laser-writing process is used to secure a diamond containing NV centers above the fiber’s core inside a polymer structure. Additionally, a metallic direct laser-written antenna structure next to the fiber facet allows efficient microwave manipulation of NV-center spins. The sensor achieves a shot-noise-limited magnetic-field sensitivity of 5.9 nT / Hz using a 15 − μ m -sized microdiamond at a microwave power of 50 mW and an optical power of 2.15 mW . Using lock-in techniques, we measure a sensitivity of 51.8 nT / Hz . Furthermore, we introduce a dual-fiber concept that enables, in combination with a direct laser-written structure, independent guiding of excitation and fluorescence light and thus reduces background autofluorescence. Moreover, controlled guiding of excitation light to the diamond while avoiding sample illumination may enable operation in light-sensitive environments such as biological tissue. While the demonstrated sensitivity is achieved using a single-fiber configuration, the dual-fiber approach provides a path toward integrating smaller diamonds, where autofluorescence would otherwise limit performance. We demonstrate the capability of vector magnetic-field measurements in the type of magnetic field used in state-of-the-art ultracold quantum gas experiments, opening a potential arena in which high resolution and high sensitivity are required.
High Resolution Image Download MS PowerPoint Slide Ensemble negatively charged nitrogen-vacancy centers in diamond are promising quantum sensors. To optimize their sensitivity, it is crucial to increase the number of spins sampled and maximize their coupling to the detection system without degrading their spin properties. In this paper, we demonstrate enhanced quantum magnetometry via a buried laser-written waveguide in diamond with 4.5 ppm nitrogen-vacancy centers. The waveguide-coupled nitrogen-vacancy centers exhibit spin coherence properties comparable to those of nitrogen-vacancy centers in pristine diamond. Waveguide-enhanced magnetic field sensing is demonstrated in a fiber-coupled integrated photonic chip, where probing an increased volume of high-density spins results in 63 pT·Hz –1/2 of DC magnetic field sensitivity and 20 pT·Hz –1/2 of AC magnetic field sensitivity. This on-chip sensor realizes at least an order of magnitude improvement in sensitivity compared to the conventional confocal detection setup, paving the way for high-sensitivity quantum magnetometry with nitrogen-vacancy ensembles.
AbstractNitrogen-vacancy (NV) centers in diamond show disruptive potential in quantum sensing, enabling groundbreaking applications in nanoscale microscopy [1] and single-cell imaging [2]. They also promise insight into processes in complex electrochemical systems such as batteries [3]. However, most successes in these applications remain bound to laboratory conditions.We present a novel architecture for an endoscopic and fully fiber-coupled quantum magnetometer. Our sensor features a 5 mm diameter head with a micro-lens optical front-end for efficient optical excitation and fluorescence collection. An FPGA integrates the control and readout functionalities, including microwave synthesis and lock-in demodulation. This highly integrated platform achieves a magnetic field sensitivity of 150 pT/√Hz, presenting a performance record for endoscopic CW-ODMR based NV-based sensors. We verify the sensor's practical utility by performing 2D magnetic field scans of a commercial battery, demonstrating its capability in a real application scenario. This work marks a significant advance in the transition of endoscopic quantum sensors from the lab to the field.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Ultimate sensitivity for quantum magnetometry using nitrogen-vacancy (NV) centers in a diamond is limited by a number of NV centers and coherence time. Microwave irradiation with a high and homogeneous power density for a large detection volume is necessary to achieve a highly sensitive magnetometer. Here, we demonstrate a microwave resonator to enhance the power density of the microwave field and an optical system with a detection volume of 1.4 × 10−3 mm3. The strong microwave field enables us to achieve 48 ns Rabi oscillation which is sufficiently faster than the phase relaxation time of NV centers. This system combined with a decoupling pulse sequence, XY16, extends the spin coherence time (T2) up to 27 times longer than that with a spin echo method. Consequently, we obtained an AC magnetic field sensitivity of 10.8 pt/Hz using the dynamical decoupling pulse sequence.
We demonstrate quantum logic enhanced sensitivity for a macroscopic ensemble of solid-state, hybrid two-qubit sensors. We achieve over a factor of 30 improvement in the single-shot signal-to-noise ratio, translating to an ac magnetic field sensitivity enhancement exceeding an order of magnitude for time-averaged measurements. Using the electronic spins of nitrogen vacancy (NV) centers in diamond as sensors, we leverage the on-site nitrogen nuclear spins of the NV centers as memory qubits, in combination with homogeneous and stable bias and control fields, ensuring that all of the ∼10^{9} two-qubit sensors are sufficiently identical to permit global control of the NV ensemble spin states. We find quantum logic sensitivity enhancement for multiple measurement protocols with varying optimal sensing intervals, including XY8 and DROID-60 dynamical decoupling, as well as correlation spectroscopy, using an applied ac magnetic field signal. The results are independent of the nature of the target signal and broadly applicable to measurements using NV centers and other solid-state spin ensembles. This work provides a benchmark for macroscopic ensembles of quantum sensors that employ quantum logic or quantum error correction algorithms for enhanced sensitivity.