Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Advanced Quantum Technologies

In Situ Spin Polarization Measurement Method and Identification of Optimal Spin Polarization Range in Atomic Magnetometer

Renjie Li, Yueyang Zhai, Jiajie Li, Qian Cao, Ying Liu

Published Feb 25, 2024• 11 citations
Publisher

Abstract

Abstract In this study, an in situ measurement method of spin polarization in single‐beam atomic magnetometer is presented. Modeling magnetic linewidth by incorporating nonlinear attenuation along the propagation direction of light and employing the output response equation of magnetometers at zero‐field resonance. Utilizing the model for fitting to extract relaxation rate information, the photon absorption cross‐sections at three temperatures are estimated to be , , and , respectively. Further, the spin polarization curves are obtained by introducing the spin polarization equations. Given the diminishing marginal utility resulting from the enhancement of performance through increased spin polarization, long‐term sensitivity is employed to determine optimal spin polarization range. The optimal long‐term sensitivity for four displayed states is (@31.5Hz), while the ultimate minimum sensitivity is 10.7 (@31.5Hz). The optimal spin polarization ranges at three temperatures are 78.9%–87.1%, 82.3%–88.5%, and 84.5%–88.4%, respectively. The measurement method applied to single‐beam magnetometer can be easily extended to multi‐axis vector magnetometer. The determination of optimal spin polarization range is of great significance for the performance and stability of the magnetometer system, improving the sensitivity of magnetic field measurement, and ensuring its widespread application in bio‐magnetic measurement.

DOI
10.1002/qute.202300287

Related papers

Measurement of Equilibrium Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometers via the Steady-State Response to the Triaxial Magnetic Field

Faming Wang, Xiujie Fang, Bozheng Xing +5 more

This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•7 citations

In-situ determination of spin polarization in a single-beam fiber-coupled spin-exchange-relaxation-free atomic magnetometer with differential detection

Yintao Ma, Zhixia Qiao, Yao Chen +8 more

The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.

Optics Express•Jan 9, 2023•5 citations

Optimal Magneto‐Optical Angle in Single‐Beam Optically Pumped Atomic Magnetometers Considering the Spatial Distribution of Spin Polarization

Yuntian Zou, Chi Fang, Jiali Liu +7 more

ABSTRACT Single‐beam optically pumped atomic magnetometers (OPAMs) are promising tools for biomagnetic measurements in nonzero‐field environments owing to their high sensitivity and compactness. However, the angle between the external bias magnetic field and the pump light affects the spin polarization of the atomic ensemble, thereby influencing the magnetometer performance and making the optimization of the magneto‐optical angle essential. In this study, a spatially resolved steady‐state spin polarization model incorporating the magneto‐optical angle is established for the first time, and an analytical expression of the spin precession signal under RF magnetic field excitation is derived. It is demonstrated that an optimal angle exists at which the magnetometer exhibits the maximum response and the highest sensitivity, which is experimentally determined to be 26° in our single‐beam OPAM. At this angle, the combined influence of the steady‐state spin polarization, spin precession projection, transmitted light intensity, and transverse spin relaxation reaches an optimal overall state, leading to a 14% enhancement in sensitivity and a 32% reduction in detection noise compared with the conventional 45° configuration. These findings provide guidance for optimizing the experimental parameters of single‐beam OPAMs for weak magnetic signal detection in nonzero‐field environments.

Advanced Quantum Technologies•Jan 1, 2026•1 citation

Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer

Jiajie Li, Ying Liu, Renjie Li +3 more

Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.

Results in Physics•Nov 30, 2023•11 citations

High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement

Junjian Tang, Yueyang Zhai, Cao Li +6 more

We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).

Optics Express•May 3, 2021•125 citations

A Novel Measurement Method for Spin Polarization Three Axis Spatial Distribution in Spin-Exchange Relaxation Free Atomic Magnetometer

Xiujie Fang, Jin Chun Li, Yanning Ma +5 more

The measurement of atomic spin polarization distribution in spin-exchange relaxation free (SERF) magnetometer is an important topic for improving the sensitivity and consistency of multi-channel magnetic field measurement applications. A novel spin polarization spatial distribution measurement method is presented based on the transient response of the magnetometer after modulating the pumped light with a chopper. Polarization is obtained by a slow-down factor based on the fast spin-exchange interaction effects. Longitudinal and transverse polarization distributions are measured simultaneously without interrupting the operation of the SERF status. Under different oscillating magnetic fields, the spin polarization is measured at the cell centroid. Residual magnetic field inside the magnetometer is obtained from the linear relationship between the precession frequency and the oscillating magnetic field. The one-dimensional polarization distributions in the x, y, and z axes are measured using a digital micromirror device with a resolution of 0.25 cm. The measurement results conform to the Lambert-Bier absorption law and the Gaussian distribution law. Furthermore, 7 × 7 two-dimensional spatial distribution measurements of polarization on the xy and yz planes are performed. Nonuniformity of 1.04 in the xy plane and 1.82 in the yz plane in the built magnetometer. Compared with other measurement methods, the distribution measurement method proposed is independent of optical depth and suitable for low polarization and high polarization applications. Based on the results of the proposed measurement method of spin polarization spatial distribution, further compensation can improve the application consistency of multi-channel magnetic field measurements and improve the sensitivity of single-channel differential measurements.

Photonics•Mar 20, 2023•2 citations
Abstract In this study, an in situ measurement method of spin polarization in single‐beam atomic magnetometer is presented. Modeling magnetic linewidth by incorporating nonlinear attenuation along the propagation direction of light and employing the output response equation of magnetometers at zero‐field resonance. Utilizing the model for fitting to extract relaxation rate information, the photon absorption cross‐sections at three temperatures are estimated to be , , and , respectively. Further, the spin polarization curves are obtained by introducing the spin polarization equations. Given the diminishing marginal utility resulting from the enhancement of performance through increased spin polarization, long‐term sensitivity is employed to determine optimal spin polarization range. The optimal long‐term sensitivity for four displayed states is (@31.5Hz), while the ultimate minimum sensitivity is 10.7 (@31.5Hz). The optimal spin polarization ranges at three temperatures are 78.9%–87.1%, 82.3%–88.5%, and 84.5%–88.4%, respectively. The measurement method applied to single‐beam magnetometer can be easily extended to multi‐axis vector magnetometer. The determination of optimal spin polarization range is of great significance for the performance and stability of the magnetometer system, improving the sensitivity of magnetic field measurement, and ensuring its widespread application in bio‐magnetic measurement.
This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.
The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.
ABSTRACT Single‐beam optically pumped atomic magnetometers (OPAMs) are promising tools for biomagnetic measurements in nonzero‐field environments owing to their high sensitivity and compactness. However, the angle between the external bias magnetic field and the pump light affects the spin polarization of the atomic ensemble, thereby influencing the magnetometer performance and making the optimization of the magneto‐optical angle essential. In this study, a spatially resolved steady‐state spin polarization model incorporating the magneto‐optical angle is established for the first time, and an analytical expression of the spin precession signal under RF magnetic field excitation is derived. It is demonstrated that an optimal angle exists at which the magnetometer exhibits the maximum response and the highest sensitivity, which is experimentally determined to be 26° in our single‐beam OPAM. At this angle, the combined influence of the steady‐state spin polarization, spin precession projection, transmitted light intensity, and transverse spin relaxation reaches an optimal overall state, leading to a 14% enhancement in sensitivity and a 32% reduction in detection noise compared with the conventional 45° configuration. These findings provide guidance for optimizing the experimental parameters of single‐beam OPAMs for weak magnetic signal detection in nonzero‐field environments.
Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
The measurement of atomic spin polarization distribution in spin-exchange relaxation free (SERF) magnetometer is an important topic for improving the sensitivity and consistency of multi-channel magnetic field measurement applications. A novel spin polarization spatial distribution measurement method is presented based on the transient response of the magnetometer after modulating the pumped light with a chopper. Polarization is obtained by a slow-down factor based on the fast spin-exchange interaction effects. Longitudinal and transverse polarization distributions are measured simultaneously without interrupting the operation of the SERF status. Under different oscillating magnetic fields, the spin polarization is measured at the cell centroid. Residual magnetic field inside the magnetometer is obtained from the linear relationship between the precession frequency and the oscillating magnetic field. The one-dimensional polarization distributions in the x, y, and z axes are measured using a digital micromirror device with a resolution of 0.25 cm. The measurement results conform to the Lambert-Bier absorption law and the Gaussian distribution law. Furthermore, 7 × 7 two-dimensional spatial distribution measurements of polarization on the xy and yz planes are performed. Nonuniformity of 1.04 in the xy plane and 1.82 in the yz plane in the built magnetometer. Compared with other measurement methods, the distribution measurement method proposed is independent of optical depth and suitable for low polarization and high polarization applications. Based on the results of the proposed measurement method of spin polarization spatial distribution, further compensation can improve the application consistency of multi-channel magnetic field measurements and improve the sensitivity of single-channel differential measurements.