Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Sciences

Noise Differentiation and Atom Number Measurement in Optical Lattice Clocks by Analyzing Clock Stabilities with Various Parameters

Guodong Zhao, Feng Guo, Xiaotong Lu, Hong Chang

Published Feb 21, 2024• 0 citations
Publisher

Abstract

We propose a method that enables the precise determination of the number of atoms in a Dick-noise-free optical lattice clock, by effectively addressing quantum projection noise. Our approach relies on conducting stability measurements at three distinct parameter sets, allowing us to differentiate between quantum projection noise, photon shot noise, and technical noise. Importantly, it enables accurate extraction of the atom number, even in the presence of photon shot noise and technical noise. We utilize numerical simulations to validate our approach, optimize the modulation parameters for minimal uncertainty, and investigate the impact of atom number fluctuations on the determinacy of our results. The numerical results show the validity of our method and demonstrate an estimated uncertainty in the atom number that is below 4% with 6.7 h measurement, provided that the standard deviation of atom number fluctuation is kept below 0.14 times the average atom number.

DOI
10.3390/app14051758

Related papers

Stability analysis in an optical lattice clock using the four-path measurement

Xiaotong Lu, Feng Guo, Jingjing Xia +3 more

In this paper, we propose a method for identifying the contribution of various sources of noise to the instability of an optical lattice clock. These sources include Dick noise, quantum projection noise, shot noise, and technical noise. By measuring the clock instability at four different sets of parameters, we can determine the frequency fluctuations due to each type of noise separately. Furthermore, we can accurately extract the absolute number of atoms, the photon number detected per atom by the photoelectric detector, and the root mean square fluctuations of the atom number. We demonstrate the effectiveness of our approach through numerical simulations, showcasing the ability to determine these parameters with an uncertainty of less than 10%. Specifically, a remarkable uncertainty of 1% can be achieved when determining the atom number.

Physical Review A•Feb 13, 2024•1 citation

Spectroscopy schemes for improved optical clock stability

Filip Butuc-Mayer

Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.

•Jan 1, 2026•0 citations

Quantum Nondemolition Detection for Strontium Optical Lattice Clock

Haosen Shang, Miguel A. Cifuentes Marin, Yannick Foucault +2 more

SummaryThe short-term frequency instability of the best optical atomic clock lies in the mid 10−17. However, the Dick effect is still an obstacle for a single operational clock closely followed by the quantum projection noise. To improve the frequency stability of the strontium optical lattice clock, we present a quantum non-demolition detection scheme based on the cavity mediated interaction between the atoms and a probe light that has a large-frequency detuning to the atomic resonance, aiming to bring the detection scheme proposed in [1] to the quantum regime. We obtained a rather small photon scattering rate, measured to be less than 0.1 photon/μs/atom, which allows us to not only preserve the atoms in the lattice but also the atomic wave function as long as the total probe time is on the order of a few microseconds. The detection noise for the number of atoms is 48/√photons atoms, implying that the frequency stability can surpass the standard quantum limit when the number of trapped atoms is larger than 2.3×104with spin squeezing protocols.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•2 citations

Comparison of Two Independent Sr Optical Clocks with 1 × 10 − 17 Stability at 10 3 s

Travis Nicholson, Michael J. Martin, Jason Williams +5 more

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two $^{87}\mathrm{Sr}$ lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.

arXiv:1210.0064•Physical Review Letters•Dec 5, 2012•249 citations

A noise-immune cavity-assisted non-destructive detection for an optical lattice clock in the quantum regime

Grégoire Vallet, Eva Bookjans, Ulrich Eismann +3 more

We present and implement a non-destructive detection scheme for the transition probability readout of an optical lattice clock. The scheme relies on a differential heterodyne measurement of the dispersive properties of lattice-trapped atoms enhanced by a high finesse cavity. By design, this scheme offers a 1st order rejection of the technical noise sources, an enhanced signal-to-noise ratio, and an homogeneous atom-cavity coupling. We theoretically show that this scheme is optimal with respect to the photon shot noise limit. We experimentally realise this detection scheme in an operational strontium optical lattice clock. The resolution is on the order of a few atoms with a photon scattering rate low enough to keep the atoms trapped after detection. This scheme opens the door to various different interrogations protocols, which reduce the frequency instability, including atom recycling, zero-dead time clocks with a fast repetition rate, and sub quantum projection noise frequency stability.

arXiv:1703.04609•New Journal of Physics•Aug 7, 2017•58 citations

通过减小碰撞导致的退相干和谱线增宽提高光晶格钟稳定度

Chihua Zhou, Xiaotong Lu, 郭峰 Guo Feng +3 more

Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.

Acta Optica Sinica•Jan 1, 2023•0 citations
We propose a method that enables the precise determination of the number of atoms in a Dick-noise-free optical lattice clock, by effectively addressing quantum projection noise. Our approach relies on conducting stability measurements at three distinct parameter sets, allowing us to differentiate between quantum projection noise, photon shot noise, and technical noise. Importantly, it enables accurate extraction of the atom number, even in the presence of photon shot noise and technical noise. We utilize numerical simulations to validate our approach, optimize the modulation parameters for minimal uncertainty, and investigate the impact of atom number fluctuations on the determinacy of our results. The numerical results show the validity of our method and demonstrate an estimated uncertainty in the atom number that is below 4% with 6.7 h measurement, provided that the standard deviation of atom number fluctuation is kept below 0.14 times the average atom number.
In this paper, we propose a method for identifying the contribution of various sources of noise to the instability of an optical lattice clock. These sources include Dick noise, quantum projection noise, shot noise, and technical noise. By measuring the clock instability at four different sets of parameters, we can determine the frequency fluctuations due to each type of noise separately. Furthermore, we can accurately extract the absolute number of atoms, the photon number detected per atom by the photoelectric detector, and the root mean square fluctuations of the atom number. We demonstrate the effectiveness of our approach through numerical simulations, showcasing the ability to determine these parameters with an uncertainty of less than 10%. Specifically, a remarkable uncertainty of 1% can be achieved when determining the atom number.
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.
SummaryThe short-term frequency instability of the best optical atomic clock lies in the mid 10−17. However, the Dick effect is still an obstacle for a single operational clock closely followed by the quantum projection noise. To improve the frequency stability of the strontium optical lattice clock, we present a quantum non-demolition detection scheme based on the cavity mediated interaction between the atoms and a probe light that has a large-frequency detuning to the atomic resonance, aiming to bring the detection scheme proposed in [1] to the quantum regime. We obtained a rather small photon scattering rate, measured to be less than 0.1 photon/μs/atom, which allows us to not only preserve the atoms in the lattice but also the atomic wave function as long as the total probe time is on the order of a few microseconds. The detection noise for the number of atoms is 48/√photons atoms, implying that the frequency stability can surpass the standard quantum limit when the number of trapped atoms is larger than 2.3×104with spin squeezing protocols.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr^{87}\mathrm{Sr}87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.
We present and implement a non-destructive detection scheme for the transition probability readout of an optical lattice clock. The scheme relies on a differential heterodyne measurement of the dispersive properties of lattice-trapped atoms enhanced by a high finesse cavity. By design, this scheme offers a 1st order rejection of the technical noise sources, an enhanced signal-to-noise ratio, and an homogeneous atom-cavity coupling. We theoretically show that this scheme is optimal with respect to the photon shot noise limit. We experimentally realise this detection scheme in an operational strontium optical lattice clock. The resolution is on the order of a few atoms with a photon scattering rate low enough to keep the atoms trapped after detection. This scheme opens the door to various different interrogations protocols, which reduce the frequency instability, including atom recycling, zero-dead time clocks with a fast repetition rate, and sub quantum projection noise frequency stability.
Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.