Effects of Microwave and Laser Power on Optical Detection Magnetic Resonance of Diamond Nitrogen Vacancy Center

Qiang Song, Yang Lu, Dingqu Zhang, Sanlei Dang, Likun Xing, Jing Liu

Published Sep 15, 2023• 1 citation
Publisher

Abstract

Using continuous wave optical detection magnetic resonance (ODMR), diamond nitrogen-vacancy (NV) center has been widely used in magnetic field measurement at the experimental stage. Microwave and laser power have significant influence on the sensitivity of magnetic field measurement. A set of confocal magnetic field detection system based on the ensemble of NV center is established. By adjusting the microwave and laser power, it is observed that the contrast and the full width at half maximum (FWHM) of the ODMR spectra change obviously. The experiment indicates that the contrast has a maximum value under the change of microwave and laser power, while the FWHM is mainly dominated by microwave power at low light intensity. Adjusting the microwave power to obtain an applicable FWHM, then reducing the laser power appropriately, the light narrowing phenomenon could be observed, and the operation above could improve the sensitivity of magnetic field measurement effectively.

DOI
10.1109/epee59859.2023.10351823

Related papers

Detection of nanowatt microwave radiation by the photoluminescence of an ensemble of negatively charged nitrogen vacancies in diamond

J. Debus, Vitalii Yu. Ivanov, D. Braukmann +5 more

We report on detecting continuous 60-GHz microwave radiation with powers in the nanowatt range by the photoluminescence of an ensemble of negatively charged nitrogen vacancy (NV−) centers in diamond at room temperature. The high contrast of the optically detected magnetic resonance and the efficient photon collection yield a magnetic field sensitivity of 86 nT/Hz for continuous-wave laser excitation with a photon energy of 2.33 eV and a power density of 93 W/cm2. The efficiency of the microwave-power-to-magnetic-field conversion amounts to 0.54 mT/W. The microwave excitation also enhances the degree of the linear polarization of NV− photoluminescence at magnetic resonance conditions, and for linearly co-polarized NV− photoluminescence and laser light, the magnetic field sensitivity is improved by about 7%.

Applied Physics Letters•Nov 5, 2018•4 citations

High-Dynamic-Range Detection of Microwave Signal on Chip Surface Based on Diamond Sensors

Ding Wang, Huan Fei Wen, Xin Li +9 more

This article proposed a microwave (MW) detection method by utilizing the effect of the dual MW on nitrogen-vacancy (NV) centers in diamond. We established a theoretical model of dual MW superposition and experimentally discovered the unusual peak in the optically detected magnetic resonance (ODMR) spectrum. The peak frequency and the full-width at half-maximum of the unusual peak, as well as fluorescence intensity in the nonresonant frequency range of the ODMR spectrum, were systematically analyzed to obtain the frequency and amplitude of the measured MW signals. The broadband MW detection was realized in a wide range of 2240–4512 MHz by utilizing the linear relation between the magnetic field and the resonant frequency in the Zeeman splitting. The experiments showed that the minimum detection power was up to 1$\mu$W. The proposed approach can greatly improve the practicability of detecting MW fields on chip surfaces by quantum engineering techniques.

IEEE Transactions on Microwave Theory and Techniques•Nov 3, 2023•10 citations

High-contrast absorption magnetometry in the visible to near-infrared range with nitrogen-vacancy ensembles

Florian Schall, Felix A. Hahl, Lukas Lindner +6 more

Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.

Optics Express•Jan 23, 2025•2 citations

Optically detected magnetic resonance of nitrogen-vacancy centers in diamond under weak laser excitation

Yong-Hong Yu, Ruizhi Zhang, Yue Xu +7 more

As promising quantum sensors, nitrogen-vacancy (N-$V$) centers in diamond have been widely used in frontier studies in condensed-matter physics, material science, and life sciences. In practical applications, weak laser excitation is favorable as it reduces the side effects of laser irradiation, such as phototoxicity and heating. Here we report a combined theoretical and experimental study of (near) zero-field optically detected magnetic resonance (ODMR) of N-$V$-center ensembles under weak 532-nm laser excitation. In this region, both the width and splitting of the ODMR spectra decrease with increasing laser power. This power dependence is reproduced with a model that accounts for the laser-induced charge neutralization of $\mathrm{N}\text{\ensuremath{-}}{V}^{\ensuremath{-}}$--${\mathrm{N}}^{+}$ pairs, which alters the local electric field environment. These results are useful for the understanding and development of N-$V$-based quantum sensing in light-sensitive applications.

arXiv:2308.13351•Physical Review Applied•Apr 26, 2024•23 citations

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•0 citations

Broadband AC Magnetic Field Sensing via Continuous wave optically detected magnetic resonance with NV Centers in diamond

Ryohei Dokai, Ryusei Okaniwa, Miku Ishizaki +2 more

The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.

quant-pharXiv:2606.05928•Japanese Journal of Applied Physics•Jun 5, 2026•0 citations
Using continuous wave optical detection magnetic resonance (ODMR), diamond nitrogen-vacancy (NV) center has been widely used in magnetic field measurement at the experimental stage. Microwave and laser power have significant influence on the sensitivity of magnetic field measurement. A set of confocal magnetic field detection system based on the ensemble of NV center is established. By adjusting the microwave and laser power, it is observed that the contrast and the full width at half maximum (FWHM) of the ODMR spectra change obviously. The experiment indicates that the contrast has a maximum value under the change of microwave and laser power, while the FWHM is mainly dominated by microwave power at low light intensity. Adjusting the microwave power to obtain an applicable FWHM, then reducing the laser power appropriately, the light narrowing phenomenon could be observed, and the operation above could improve the sensitivity of magnetic field measurement effectively.
We report on detecting continuous 60-GHz microwave radiation with powers in the nanowatt range by the photoluminescence of an ensemble of negatively charged nitrogen vacancy (NV−) centers in diamond at room temperature. The high contrast of the optically detected magnetic resonance and the efficient photon collection yield a magnetic field sensitivity of 86 nT/Hz for continuous-wave laser excitation with a photon energy of 2.33 eV and a power density of 93 W/cm2. The efficiency of the microwave-power-to-magnetic-field conversion amounts to 0.54 mT/W. The microwave excitation also enhances the degree of the linear polarization of NV− photoluminescence at magnetic resonance conditions, and for linearly co-polarized NV− photoluminescence and laser light, the magnetic field sensitivity is improved by about 7%.
This article proposed a microwave (MW) detection method by utilizing the effect of the dual MW on nitrogen-vacancy (NV) centers in diamond. We established a theoretical model of dual MW superposition and experimentally discovered the unusual peak in the optically detected magnetic resonance (ODMR) spectrum. The peak frequency and the full-width at half-maximum of the unusual peak, as well as fluorescence intensity in the nonresonant frequency range of the ODMR spectrum, were systematically analyzed to obtain the frequency and amplitude of the measured MW signals. The broadband MW detection was realized in a wide range of 2240–4512 MHz by utilizing the linear relation between the magnetic field and the resonant frequency in the Zeeman splitting. The experiments showed that the minimum detection power was up to 1μ\muμW. The proposed approach can greatly improve the practicability of detecting MW fields on chip surfaces by quantum engineering techniques.
Magnetometry with nitrogen-vacancy (NV) centers in diamond has so far been measured via emission of light from NV centers or via absorption at the singlet transition at 1042 nm. Here, we demonstrate a phenomenon of broadband optical absorption by the NV centers starting in the emission wavelength and reaching up to 1000 nm. The measurements are enabled by a high-finesse cavity, which is used for room-temperature continuous wave pump-probe experiments. The red to infrared probe beam shows the typical optically detected magnetic resonance (ODMR) signal of the NV spin with contrasts up to 42 %. This broadband optical absorption has not yet been reported in terms of NV magnetometry. We argue that the lower level of the absorbing transition could be the energetically lower NV singlet state, based on the increased optical absorption for a resonant microwave field and the spectral behavior. Investigations of the photon-shot-noise-limited sensitivity show improvements with increasing probe wavelength, reaching an optimum of 7.5pT/Hz. The results show significantly improved ODMR contrast compared to emission-based magnetometry. This opens a new detection wavelength regime with coherent laser signal detection for high-sensitivity NV magnetometry.
As promising quantum sensors, nitrogen-vacancy (N-VVV) centers in diamond have been widely used in frontier studies in condensed-matter physics, material science, and life sciences. In practical applications, weak laser excitation is favorable as it reduces the side effects of laser irradiation, such as phototoxicity and heating. Here we report a combined theoretical and experimental study of (near) zero-field optically detected magnetic resonance (ODMR) of N-VVV-center ensembles under weak 532-nm laser excitation. In this region, both the width and splitting of the ODMR spectra decrease with increasing laser power. This power dependence is reproduced with a model that accounts for the laser-induced charge neutralization of $\mathrm{N}\text{\ensuremath{-}}{V}^{\ensuremath{-}}$--N+{\mathrm{N}}^{+}N+ pairs, which alters the local electric field environment. These results are useful for the understanding and development of N-VVV-based quantum sensing in light-sensitive applications.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.