Fluorescence Lifetime Sensing with Two-Photon Interferometry

Ashley Lyons, Vytautas Žičkus, Raúl Álvarez-Mendoza, Danilo Triggiani, Vincenzo Tamma, Manlio Tassieri, Daniele Faccio

Published Jan 1, 2023• 0 citations
Publisher

Abstract

The temporal resolution of fluorescence lifetime microscopy is typically restricted to 100s picoseconds due to detector response. We present a novel technique, inspired by quantum interferometry, that is limited only by the optical pulse duration.
DOI
10.1364/cosi.2023.cm3b.3

Related papers

Fluorescence lifetime measurement based on quantum sensing

Giuseppe Di Blasio, Federico Simoni, Lorenzo Uboldi +5 more

Quantum light sources, such as entangled photons, offers unique advantages for bio-sensing of light sensitive samples, providing background free and high SNR measurements at ultra-low photon flux. We built a modular set-up based on SPDC entangled photon pairs generation by using a pulsed laser and several single-photon detectors with different time resolution and quantum efficiency to investigate fluorescent complexes. This toolkit paves the way for minimally invasive fluorescence lifetime sensing towards next generation in vivo studies.

Quantum Effects and Measurement Techniques in Biology and Biophotonics•Mar 4, 2026•0 citations

Ultrafast Single-Photon Detection based on Optical Kerr Gates

Assegid M. Flatae, Abdul-Hamid Fattah, Amr Farrag +1 more

The generation and efficient detection of ultrafast single photons is at the forefront of modern optical science, and it offers an unprecedented set of capabilities, for instance, in the area of quantum information science, high-sensitivity detection, and remote sensing [1] - [3] . In addition, it provides a powerful analysis tool in the life sciences at the single-molecule level [4] . The detection of single photons is currently restricted by the limited time resolution (a few picoseconds) of the available single-photon detectors.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•0 citations

Optical Lithography and Atom Localization beyond the Diffraction Limit via Rabi Gradient

Zeyang Liao

The resolution of traditional optical microscope and optical lithography is limited by about half wavelength of the light source, which is well known as the diffraction limit or Abbe limit. The resolution limit is due to the missing of high spatial frequency components in the far-field. One way to achieve high resolution is to move the detector into the near-field region where the evanescent wave can be collected. However, these methods are surface-bound and usually very slow which have limited applications. It has long been an interesting and important question about how to overcome the diffraction limit in the far-field.\n\nFor optical lithography, a number of methods have been proposed to overcome the diffraction limit such as multi-photon scanning, quantum entanglement, quantum inspired process (e.g., dopperlon), and quantum dark state. However, these methods either require multi-photon absorber, quantum entanglement, or multi-energy levels, which restrict them from extending to higher resolution in practice. In this thesis, we showed that sub-diffraction-limited resolution can be generated by the coherent Rabi gradient. This method does not require multi-photon absorber or quantum entanglement but just quantum coherence of the medium. Extension from lower resolution to higher resolution is very straightforward where we just need to increase the pulse intensity or pulse duration. We also proposed two atom lithography experiments based on the Rabi gradient. The first one uses Rubidium Rydberg atom and microwave where we showed that sub-micrometer line spacing is possible. The second one uses Chromium atom and optical field where we showed that sub-10nm line spacing is possible while the wavelength of the light is about 400nm.\n\nFor optical imaging, a number of methods have also been proposed to achieve super-resolution such as multi-photon microscope, stimulated-emission-depletion, structured illumination microscopy, centroid-based techniques and metamaterial-based lens. Here, we will show a new method to achieve resolution beyond the diffraction limit which we called it resonance fluorescence microscopy. Resonance fluorescence has been proposed to localize a single atom with resolution beyond the diffraction limit. The separation between two atoms can also be extracted from the resonance\nfluorescence spectrum. To develop it as microscopy, we need to evaluate the resonance fluorescence spectrum of multiple-atom system. We analytically solved the general feature of the spectrum when the Rabi frequency is much larger than the dipole-dipole interaction and showed how to extract the spatial information of the atoms with resolution far beyond the diffraction limit. This method is entirely based on far-field techniques and it does not require point-by-point scanning.

•Jul 28, 2014•0 citations

Temporal filtering characteristics of gated InGaAs/InP single-photon detectors for coincidence measurement

Yaqing Jin, Ruifang Dong, Runai Quan +3 more

Semiconductor single-photon avalanche detectors (SPADs) have played an important role in practical quantum communication technology due to their advantages of small size, low cost and easy operation. Among them, InGaAs/InP SPADs have been widely used in fiber-optic quantum key distribution systems due to their response wavelength range in a near-infrared optical communication band. In order to avoid the influence of dark count and afterpulsing on single photon detection, the gated quenching technologies are widely applied to the InGaAs/InP SPADs. Typically, the duration of gate pulse is set to be as short as a few nanoseconds or even less. As the detection of the arrival of single photons depends on the coincidence between the arrival time of gate pulse and the arrival time of photon, the gate pulse duration of the InGaAs/InP SPADs inevitably affects the effective detection of the single photons. Without the influence of dispersion, the temporal width of the transmitted photons is usually on the order of picoseconds or even less, which is much shorter than the gate width of the InGaAs/InP SPAD. Therefore, the gate width normally has no influence on the temporal measurement of the detected photons. However, in quantum systems involving large dispersion, such as the long-distance fiber-optic quantum communication system, the temporal width of the transmitted photons is significantly broadened by the experienced dispersion so that it may approach to or even exceed the gate width of the single-photon detector. As a result, the effect of the gate width on the recording of the arrival time of the dispersed photons should be taken into account. In this paper, the influence of the gate width coupled to the InGaAs/InP single photon detectors on the measurement of the two-photon coincidence time width is studied both theoretically and experimentally. The theoretical analysis and experimental results are in good agreement with each other, showing that the finally measured coincidence time width of the two-photon state after dispersion is not more than half of the effective gate pulses width. The maximum observable coincidence time width based on the gated single photon detector is fundamentally limited by the gate width, which restricts its applications in quantum information processing based on the two-photon temporal correlation measurement.

Acta Physica Sinica•Dec 15, 2020•1 citation

Fluorophore discrimination by tracing quantum interference in fluorescence microscopy

Arijit K. De, Debjit Roy, Debabrata Goswami

We show fluorescence-detected quantum interference in a microscope setup and demonstrate selective enhancement or suppression of fluorophores using femtosecond pulse-pair excitation with periodic modulation of the interpulse phase.

Physical Review A•Jan 21, 2011•9 citations

Breaking the diffraction limit using fluorescence quantum coherence

Wenwen Li, Zhongyang Wang

The classical optical diffraction limit can be overcome by exploiting the quantum properties of light in several theoretical studies; however, they mostly rely on an entangled light source. Recent experiments have demonstrated that quantum properties are preserved in many fluorophores, which makes it possible to add a new dimension of information for super-resolution fluorescence imaging. Here, we developed a statistical quantum coherence model for fluorescence emitters and proposed a new super-resolution method using fluorescence quantum coherence in fluorescence microscopy. In this study, by exploiting a single-photon avalanche detector (SPAD) array with a time-correlated single-photon-counting technique to perform spatial-temporal photon statistics of fluorescence coherence, the subdiffraction-limited spatial separation of emitters is obtained from the determined coherence. We numerically demonstrate an example of two-photon interference from two common fluorophores using an achievable experimental procedure. Our model provides a bridge between the macroscopic partial coherence theory and the microscopic dephasing and spectral diffusion mechanics of emitters. By fully taking advantage of the spatial-temporal fluctuations of the emitted photons as well as coherence, our quantum-enhanced imaging method has the significant potential to improve the resolution of fluorescence microscopy even when the detected signals are weak.

Optics Express•Mar 21, 2022•6 citations
Quantum light sources, such as entangled photons, offers unique advantages for bio-sensing of light sensitive samples, providing background free and high SNR measurements at ultra-low photon flux. We built a modular set-up based on SPDC entangled photon pairs generation by using a pulsed laser and several single-photon detectors with different time resolution and quantum efficiency to investigate fluorescent complexes. This toolkit paves the way for minimally invasive fluorescence lifetime sensing towards next generation in vivo studies.
The generation and efficient detection of ultrafast single photons is at the forefront of modern optical science, and it offers an unprecedented set of capabilities, for instance, in the area of quantum information science, high-sensitivity detection, and remote sensing [1] - [3] . In addition, it provides a powerful analysis tool in the life sciences at the single-molecule level [4] . The detection of single photons is currently restricted by the limited time resolution (a few picoseconds) of the available single-photon detectors.
The resolution of traditional optical microscope and optical lithography is limited by about half wavelength of the light source, which is well known as the diffraction limit or Abbe limit. The resolution limit is due to the missing of high spatial frequency components in the far-field. One way to achieve high resolution is to move the detector into the near-field region where the evanescent wave can be collected. However, these methods are surface-bound and usually very slow which have limited applications. It has long been an interesting and important question about how to overcome the diffraction limit in the far-field.\n\nFor optical lithography, a number of methods have been proposed to overcome the diffraction limit such as multi-photon scanning, quantum entanglement, quantum inspired process (e.g., dopperlon), and quantum dark state. However, these methods either require multi-photon absorber, quantum entanglement, or multi-energy levels, which restrict them from extending to higher resolution in practice. In this thesis, we showed that sub-diffraction-limited resolution can be generated by the coherent Rabi gradient. This method does not require multi-photon absorber or quantum entanglement but just quantum coherence of the medium. Extension from lower resolution to higher resolution is very straightforward where we just need to increase the pulse intensity or pulse duration. We also proposed two atom lithography experiments based on the Rabi gradient. The first one uses Rubidium Rydberg atom and microwave where we showed that sub-micrometer line spacing is possible. The second one uses Chromium atom and optical field where we showed that sub-10nm line spacing is possible while the wavelength of the light is about 400nm.\n\nFor optical imaging, a number of methods have also been proposed to achieve super-resolution such as multi-photon microscope, stimulated-emission-depletion, structured illumination microscopy, centroid-based techniques and metamaterial-based lens. Here, we will show a new method to achieve resolution beyond the diffraction limit which we called it resonance fluorescence microscopy. Resonance fluorescence has been proposed to localize a single atom with resolution beyond the diffraction limit. The separation between two atoms can also be extracted from the resonance\nfluorescence spectrum. To develop it as microscopy, we need to evaluate the resonance fluorescence spectrum of multiple-atom system. We analytically solved the general feature of the spectrum when the Rabi frequency is much larger than the dipole-dipole interaction and showed how to extract the spatial information of the atoms with resolution far beyond the diffraction limit. This method is entirely based on far-field techniques and it does not require point-by-point scanning.
Semiconductor single-photon avalanche detectors (SPADs) have played an important role in practical quantum communication technology due to their advantages of small size, low cost and easy operation. Among them, InGaAs/InP SPADs have been widely used in fiber-optic quantum key distribution systems due to their response wavelength range in a near-infrared optical communication band. In order to avoid the influence of dark count and afterpulsing on single photon detection, the gated quenching technologies are widely applied to the InGaAs/InP SPADs. Typically, the duration of gate pulse is set to be as short as a few nanoseconds or even less. As the detection of the arrival of single photons depends on the coincidence between the arrival time of gate pulse and the arrival time of photon, the gate pulse duration of the InGaAs/InP SPADs inevitably affects the effective detection of the single photons. Without the influence of dispersion, the temporal width of the transmitted photons is usually on the order of picoseconds or even less, which is much shorter than the gate width of the InGaAs/InP SPAD. Therefore, the gate width normally has no influence on the temporal measurement of the detected photons. However, in quantum systems involving large dispersion, such as the long-distance fiber-optic quantum communication system, the temporal width of the transmitted photons is significantly broadened by the experienced dispersion so that it may approach to or even exceed the gate width of the single-photon detector. As a result, the effect of the gate width on the recording of the arrival time of the dispersed photons should be taken into account. In this paper, the influence of the gate width coupled to the InGaAs/InP single photon detectors on the measurement of the two-photon coincidence time width is studied both theoretically and experimentally. The theoretical analysis and experimental results are in good agreement with each other, showing that the finally measured coincidence time width of the two-photon state after dispersion is not more than half of the effective gate pulses width. The maximum observable coincidence time width based on the gated single photon detector is fundamentally limited by the gate width, which restricts its applications in quantum information processing based on the two-photon temporal correlation measurement.
The classical optical diffraction limit can be overcome by exploiting the quantum properties of light in several theoretical studies; however, they mostly rely on an entangled light source. Recent experiments have demonstrated that quantum properties are preserved in many fluorophores, which makes it possible to add a new dimension of information for super-resolution fluorescence imaging. Here, we developed a statistical quantum coherence model for fluorescence emitters and proposed a new super-resolution method using fluorescence quantum coherence in fluorescence microscopy. In this study, by exploiting a single-photon avalanche detector (SPAD) array with a time-correlated single-photon-counting technique to perform spatial-temporal photon statistics of fluorescence coherence, the subdiffraction-limited spatial separation of emitters is obtained from the determined coherence. We numerically demonstrate an example of two-photon interference from two common fluorophores using an achievable experimental procedure. Our model provides a bridge between the macroscopic partial coherence theory and the microscopic dephasing and spectral diffusion mechanics of emitters. By fully taking advantage of the spatial-temporal fluctuations of the emitted photons as well as coherence, our quantum-enhanced imaging method has the significant potential to improve the resolution of fluorescence microscopy even when the detected signals are weak.