Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

A Method of Evaluating NV centers Concentration by UV–Vis Transmittance Spectra

Yanyan Zhang, Libin Zhang, Dongliang Zhang, Yichen Li, Sheng Liu, Bo Yang, Zhiyin Gan

Published Aug 1, 2023• 1 citation
Publisher

Abstract

Abstract The ultraviolet-visible (UV-Vis) spectrum was not generally considered an available method for measuring the concentration of negatively charged nitrogen-vacancy (NV-, NV center). In this study, we propose the idea of evaluating the concentration of NV center by the slope of the UV-Vis spectrum. To establish this new method we synthesized diamonds with different NV center concentrations by the chemical vapor deposition (CVD) method. We then measured the zero-phonon line (ZPL) intensity of PL spectra at 637 nm and estimated the concentration of the NV centers as a baseline for comparison to our new UV-Vis method. The UV-Vis transmission spectra were then measured and transformed to relative absorption coefficient spectra. Slopes of the transformed UV-Vis spectra between 400 nm and 800 nm were calculated and compared with the ZPL intensities. The results show a strong positive correlation between the slopes of the absorption spectra and the ZPL intensities of PL spectra at 637 nm. Therefore, this paper demonstrates the feasibility of estimating the concentration of the NV centers from measuring the transmission UV-Vis spectrum.

DOI
10.1088/1742-6596/2585/1/012001

Related papers

Photoluminescence characterization of NV centers in CVD diamond as a function of different nitrogen doping levels for quantum sensing applications

Sierra Gómez, Javier, Silva Neto, José Vieira da, Trava Airoldi, Vladimir Jesus +1 more

Nitrogen-vacancy (NV) centers in single-crystal CVD diamond are promising candidates for quantum sensing due to their remarkable optical and spin properties [1]. These defects exhibit stable photoluminescence (PL), long spin coherence times, and high sensitivity to external fields [2]. In this study, we present a room-temperature PL characterization of NV centers excited with a 532 nm laser. The setup was optimized for high signal-to-noise ratio and spectral resolution. Key parameters analyzed include emission intensity, zero-phonon line (ZPL) at ~637 nm, phonon sidebands, and the charge state distribution between NV⁰ and NV⁻. The NV⁻ state, crucial for spin-based sensing, is evaluated to understand its stability under different nitrogen doping conditions [3]. The relative intensities of NV⁰ and NV⁻ provide insights into nitrogen incorporation and vacancy formation. These results contribute to optimizing synthesis conditions for enhanced NV⁻ concentration, supporting the advancement of diamond-based quantum sensing technologies.

•Jan 1, 2025•0 citations

Laser spectroscopic characterization of negatively charged nitrogen-vacancy (NV−) centers in diamond

Shova D. Subedi, Vladimir Fedorov, Jeremy M. Peppers +4 more

We report on the spectroscopic and laser characterization of negatively charged nitrogen-vacancy (NV−) centers in diamond. Spectroscopic properties such as absorption and emission spectra as well as kinetics were studied, and parameters such as cross-sections and lifetimes were estimated. A vibronic band of NV0 with zero phonon line (ZPL) at 575 nm was detected under 532 nm pulsed excitation due to the photoionization of NV−. Transmission of 532 nm pump pulses saturate around ∼10%, which is much smaller than the theoretical level. Δk/k0 kinetics revealed slow recovery of NV− centers after photoionization under 532 nm pumping, which involved different relaxation channels depending on the probe beam wavelengths. Localization of the electrons in the metastable state of NV0 centers resulted in higher saturated transmission of 632 nm pump.

Optical Materials Express•Apr 5, 2019•73 citations

Peculiarities of absorption and luminescence spectra of nitrogen-vacancy color centers in diamond crystals

Anton K. Vershovskii, Alexander K. Dmitriev

We have studied photoluminescence spectra of nitrogen-vacancy (NV) centers upon their pumping by short-wavelength visible and near-UV radiation. We have shown that NV 0 centers, as distinct from NV − centers have an absorption line in the UV range. Inversion of the zero-phonon line of NV − centers has been shown and interpreted.

Optics and Spectroscopy•Mar 1, 2014•3 citations

Rapid determination of single substitutional nitrogen Ns concentration in diamond from UV-Vis spectroscopy

Tingpeng Luo, Lukas Lindner, Rémi Blinder +6 more

Single substitutional nitrogen atoms Ns0 are the prerequisite to create nitrogen-vacancy (NV) centers in diamonds. They not only serve as the electron donors to create the desired NV− center and provide charge stability against photo-ionisation but also are the main source of decoherence. Therefore, precise and quick determination of Ns0 concentration is a key advantage to a multitude of NV-related research in terms of material improvement as well as applications. Here, we present a method to determine the Ns0 concentration based on absorption spectroscopy in the UV-Visible range and fitting the 270 nm absorption band. UV-Visible spectroscopy has experimental simplicity and widespread availability that bear advantages over established methods. It allows a rapid determination of Ns0 densities, even for large numbers of samples. Our method shows further advantages in determining low concentrations as well as the ability to measure locally, which is highly relevant for diamonds with largely varying Ns0 concentrations in a single crystal. A cross-check with electron paramagnetic resonance shows high reliability of our method and yields the absorption cross section of the 270 nm absorption band σ=1.96±0.15 cm−1 ppm−1 (in common logarithm) or σe=4.51±0.35 cm−1 ppm−1 (in natural logarithm), which serves as a reference to determine Ns0 concentrations and makes our method applicable for others without the need for a known Ns0-reference sample and calibration. We provide a rapid, practical, and replicable pathway that is independent of the machine used and can be widely implemented as a standard characterization method for the determination of Ns0 concentrations.

arXiv:2207.14278•Applied Physics Letters•Aug 8, 2022•21 citations

Fabrication and characterization of diamond nitrogen-vacancy center through argon ions etching

Xiaokui Zang, Zhiqiang Cao, Jing Liu +2 more

Abstract The diamond nitrogen-vacancy center with a negative charge (NV−) exhibits exceptional optical properties and enables highly sensitive detection of multiple physical quantities. The development of a simple and efficient method for fabricating NV− centers in diamonds holds significant importance in promoting their widespread application. The fabrication method of NV− centers is explored in this work, utilizing high-energy photons emitted by argon ions to induce vacancies in type Ia diamond substrates. The processed samples are optical characterized, and the characteristic peak and zero phonon line corresponding to the NV− center can be observed in Raman and photoluminescence spectra respectively. The concentration of NV− centers in samples could reach up to 153.9 ppb, estimated by integrating the fluorescence intensity of the photoemission spectrum. The samples exhibit the spin characterization of NV− centers, which achieve a maximum contrast of 1.5% in the optical detection magnetic resonance (ODMR) spectra.

Journal of Physics Conference Series•May 1, 2024•0 citations

Investigation of zero-phonon line characteristics in ensemble nitrogen-vacancy centers at 1.6 K–300 K

Zhenrong Zhang, Huan Fei Wen, Ziheng Gao +8 more

The ensemble of nitrogen-vacancy (NV) centers is widely used in quantum information transmission, high-precision magnetic field, and temperature sensing due to their advantages of long-lived state and the ability to be pumped by optical cycling. In this study, we investigate the zero-phonon line behavior of the two charge states of NV centers by measuring the photoluminescence of the NV center at 1.6 K-300 K. The results demonstrate a positional redshift, an increase in line width, and a decrease in fluorescence intensity for the ZPL of NV0 and NV- as the temperature increased. In the range of 10 K to 140 K, the peak shift with high concentrations of NV- revealed an anomaly of bandgap reforming. The peak position undergoes a blueshift and then a redshift as temperature increases. Furthermore, the transformation between NV0 and NV- with temperature changes has been obtained in diamonds with different nitrogen concentrations. This study explored the ZPL characteristics of NV centers in various temperatures, and the findings are significant for the development of high-resolution temperature sensing and high-precision magnetic field sensing in ensemble NV centers.

Optics Express•Apr 17, 2024•2 citations
Abstract The ultraviolet-visible (UV-Vis) spectrum was not generally considered an available method for measuring the concentration of negatively charged nitrogen-vacancy (NV-, NV center). In this study, we propose the idea of evaluating the concentration of NV center by the slope of the UV-Vis spectrum. To establish this new method we synthesized diamonds with different NV center concentrations by the chemical vapor deposition (CVD) method. We then measured the zero-phonon line (ZPL) intensity of PL spectra at 637 nm and estimated the concentration of the NV centers as a baseline for comparison to our new UV-Vis method. The UV-Vis transmission spectra were then measured and transformed to relative absorption coefficient spectra. Slopes of the transformed UV-Vis spectra between 400 nm and 800 nm were calculated and compared with the ZPL intensities. The results show a strong positive correlation between the slopes of the absorption spectra and the ZPL intensities of PL spectra at 637 nm. Therefore, this paper demonstrates the feasibility of estimating the concentration of the NV centers from measuring the transmission UV-Vis spectrum.
Nitrogen-vacancy (NV) centers in single-crystal CVD diamond are promising candidates for quantum sensing due to their remarkable optical and spin properties [1]. These defects exhibit stable photoluminescence (PL), long spin coherence times, and high sensitivity to external fields [2]. In this study, we present a room-temperature PL characterization of NV centers excited with a 532 nm laser. The setup was optimized for high signal-to-noise ratio and spectral resolution. Key parameters analyzed include emission intensity, zero-phonon line (ZPL) at ~637 nm, phonon sidebands, and the charge state distribution between NV⁰ and NV⁻. The NV⁻ state, crucial for spin-based sensing, is evaluated to understand its stability under different nitrogen doping conditions [3]. The relative intensities of NV⁰ and NV⁻ provide insights into nitrogen incorporation and vacancy formation. These results contribute to optimizing synthesis conditions for enhanced NV⁻ concentration, supporting the advancement of diamond-based quantum sensing technologies.
We report on the spectroscopic and laser characterization of negatively charged nitrogen-vacancy (NV−) centers in diamond. Spectroscopic properties such as absorption and emission spectra as well as kinetics were studied, and parameters such as cross-sections and lifetimes were estimated. A vibronic band of NV0 with zero phonon line (ZPL) at 575 nm was detected under 532 nm pulsed excitation due to the photoionization of NV−. Transmission of 532 nm pump pulses saturate around ∼10%, which is much smaller than the theoretical level. Δk/k0 kinetics revealed slow recovery of NV− centers after photoionization under 532 nm pumping, which involved different relaxation channels depending on the probe beam wavelengths. Localization of the electrons in the metastable state of NV0 centers resulted in higher saturated transmission of 632 nm pump.
Single substitutional nitrogen atoms Ns0 are the prerequisite to create nitrogen-vacancy (NV) centers in diamonds. They not only serve as the electron donors to create the desired NV− center and provide charge stability against photo-ionisation but also are the main source of decoherence. Therefore, precise and quick determination of Ns0 concentration is a key advantage to a multitude of NV-related research in terms of material improvement as well as applications. Here, we present a method to determine the Ns0 concentration based on absorption spectroscopy in the UV-Visible range and fitting the 270 nm absorption band. UV-Visible spectroscopy has experimental simplicity and widespread availability that bear advantages over established methods. It allows a rapid determination of Ns0 densities, even for large numbers of samples. Our method shows further advantages in determining low concentrations as well as the ability to measure locally, which is highly relevant for diamonds with largely varying Ns0 concentrations in a single crystal. A cross-check with electron paramagnetic resonance shows high reliability of our method and yields the absorption cross section of the 270 nm absorption band σ=1.96±0.15 cm−1 ppm−1 (in common logarithm) or σe=4.51±0.35 cm−1 ppm−1 (in natural logarithm), which serves as a reference to determine Ns0 concentrations and makes our method applicable for others without the need for a known Ns0-reference sample and calibration. We provide a rapid, practical, and replicable pathway that is independent of the machine used and can be widely implemented as a standard characterization method for the determination of Ns0 concentrations.
Abstract The diamond nitrogen-vacancy center with a negative charge (NV−) exhibits exceptional optical properties and enables highly sensitive detection of multiple physical quantities. The development of a simple and efficient method for fabricating NV− centers in diamonds holds significant importance in promoting their widespread application. The fabrication method of NV− centers is explored in this work, utilizing high-energy photons emitted by argon ions to induce vacancies in type Ia diamond substrates. The processed samples are optical characterized, and the characteristic peak and zero phonon line corresponding to the NV− center can be observed in Raman and photoluminescence spectra respectively. The concentration of NV− centers in samples could reach up to 153.9 ppb, estimated by integrating the fluorescence intensity of the photoemission spectrum. The samples exhibit the spin characterization of NV− centers, which achieve a maximum contrast of 1.5% in the optical detection magnetic resonance (ODMR) spectra.
The ensemble of nitrogen-vacancy (NV) centers is widely used in quantum information transmission, high-precision magnetic field, and temperature sensing due to their advantages of long-lived state and the ability to be pumped by optical cycling. In this study, we investigate the zero-phonon line behavior of the two charge states of NV centers by measuring the photoluminescence of the NV center at 1.6 K-300 K. The results demonstrate a positional redshift, an increase in line width, and a decrease in fluorescence intensity for the ZPL of NV0 and NV- as the temperature increased. In the range of 10 K to 140 K, the peak shift with high concentrations of NV- revealed an anomaly of bandgap reforming. The peak position undergoes a blueshift and then a redshift as temperature increases. Furthermore, the transformation between NV0 and NV- with temperature changes has been obtained in diamonds with different nitrogen concentrations. This study explored the ZPL characteristics of NV centers in various temperatures, and the findings are significant for the development of high-resolution temperature sensing and high-precision magnetic field sensing in ensemble NV centers.