Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Quantum Image Distillation with Undetected Photon Beam

Jorge Fuenzalida, Marta Gilaberte Basset, Sebastian Töpfer, Juan P. Torres, Markus Gräfe

Published Jun 26, 2023• 0 citations
Publisher

Abstract

Imaging via nonlinear interferometers make use of induced coherence and take advantage of photon pair correlations to image an object without detecting the photons that illuminate the object [1]. The object's information is transferred from the photon that illuminates the object to the interference pattern of its partner photon, which is detected [2]. Spontaneous parametric down conversion allows to utilize photon pairs with large spectral separation. This fact becomes relevant if we need to image at wavelengths with detection constraints, e.g., mid-infrared, hyperspectral, or terahertz wavelengths [3], [4].

DOI
10.1109/cleo/europe-eqec57999.2023.10232462

Related papers

Experimental quantum imaging distillation with undetected light

Jorge Fuenzalida, Marta Gilaberte Basset, Sebastian Töpfer +2 more

Imaging based on the induced coherence effect makes use of photon pairs to obtain information of an object without detecting the light that probes it. While one photon illuminates the object, only its partner is detected, so no measurement of coincidence events is needed. The sought-after object's information is revealed, observing a certain interference pattern on the detected photon. Here, we demonstrate experimentally that this imaging technique can be made resilient to noise. We introduce an imaging distillation approach based on the interferometric modulation of the signal of interest. We show that our scheme can generate a high-quality image of an object even against noise levels up to 250 times the actual signal of interest. We also include a detailed theoretical explanation of our findings.

arXiv:2301.02529•Science Advances•Aug 30, 2023•32 citations

Quantum imaging with undetected photons

Filip Krajinić, J.R. Leon-Tores, M. Kumar +3 more

We present principles of quantum imaging with undetected photons (QIUP) and show modifications we made to the nonlinear interferometer for QUIP in order to use off-axes holography for faster image reconstruction. We present images made by off-axes quantum holography (OAQH) and discuss image capabilities of the system. In this work we use a pair of quantum correlated photons, generated by spontaneous parametric down-conversion in a non-linear crystal; one photon form a pair interacts with object, and another is detected. In our system both photons are in near infra-red, but by slight modifications they will be in different spectral regions, interacting photons in mid infra-red, detected photons in visible or near infra-ed. This opens very useful applications of QIUP for imaging and sensing in MIR.

International Conference on Transparent Optical Networks•Jul 14, 2024•1 citation

Sub-Diffraction Near-Field Imaging with Undetected Photons using Thin Sources of Photon Pairs

Elkin A. Santos, Sina Saravi, Andres Vega +2 more

Quantum imaging with undetected photons allows for imaging an object by detecting photons that never interacted with it, using the correlation between photon pairs generated in the process of spontaneous parametric down conversion (SPDC) [1] . Through SPDC in a χ (2) material, a pump (P) photon of wavelength λ P can split into a pair of signal (S) and idler (I) photons, such that 1/ λ P = 1/ λ S + 1/ λ I . In such imaging schemes, the object’s optical properties at λ I , such as its absorption profile, can be inferred by only imaging the signal photons. Thus, one can image in challenging spectral ranges, such as mid-IR for λ I , using detectors in the visible for λ S [1] . In this scheme, the resolution is fundamentally diffraction-limited to the wavelength that interacts with the object, λ I [2] . We show that one can go beyond this diffraction limit by placing the object in the near-field of a subwavelength thin SPDC source, as shown schematically in Fig. 1(a) , through transferring the near-field information at λ I into propagating modes at λ S that can be detected in the far field. In this scheme, the resolution of imaging the object at λ I is determined by the detected signal wavelength λ S . As an application, we numerically demonstrate how two closely-spaced small scatterers at mid-IR can be resolved with a visible-range resolution.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•0 citations

High Resolution Hyperspectral Quantum Infrared Imaging with Undetected Photons

Aadi Suketu Bharatia, Vidya Prakash Muppalla, Ananya Asthana +4 more

Quantum sensing in the infrared regime often demands the use of expensive and cryogenically operated detectors. Nonlinear interferometry has paved the way for information transfer from the infrared to the near--infrared or visible regime in various quantum technologies. A particularly interesting application of these interferometers involves spectrally--resolved quantum imaging using undetected photons, enabled by the use of temperature--tunable parametric amplifiers. In this work, we demonstrate spectrally resolved transmission imaging with undetected photons around 1550 nm using a spontaneous parametric down conversion based folded nonlinear interferometric scheme, registering the attenuation of a zebrafish larva as a biological feasibility test. We characterize and calibrate the interferometer, having achieved spectrally resolved interference fringes with a maximum baseline visibility of $\sim 74\%$ in the near--infrared regime. Phase--stepped readout of a grating spectrometer gives a resolving power of $\sim1460$ (from the spectrometer's point spread function) at 1550 nm, and $\sim 730$ from the coherence length, the finest reported for imaging with undetected photons, over an instantaneous spectral window of $\approx 51$ cm$^{-1}$.

quant-pharXiv:2610.32292•Oct 26, 2026•0 citations

Off-axis holographic imaging with undetected light

Josué Ricardo León-Torres, Filip Krajinić, Mohit Kumar +5 more

Quantum imaging with undetected light (QIUL) leverages the quantum correlations of photon pairs generated via spontaneous parametric down-conversion (SPDC) to retrieve both amplitude and phase information of an object. This method enables illumination and detection at distinct wavelength ranges, utilizing advanced detection technology in the visible spectrum while probing the object at an exotic wavelength. Here, we experimentally demonstrate a QIUL technique incorporating Fourier off-axis holography within a hybrid-type induced-coherence nonlinear interferometer. Our approach reconstructs the amplitude and phase information of an object in a single shot using a wide-field configuration, presenting a viable alternative to multi-frame acquisition techniques such as phase-shifting holography.

Optics Express•Aug 30, 2024•17 citations

New progress in quantum imaging with undetected photons (Conference Presentation)

Markus Gräfe, Marta Gilaberte Basset, Josué R. León Torres

Since the second quantum revolution, the growing exploitation of quantum states led to many sophisticated and novel applications [Phil. Trans. R. Soc. Lond. A 361, 1655 (2003). Former, mainly academic research is more and more transferred into real-world quantum technology ready to serve practical tasks. Today, the quantum computer is within reach, satellite based quantum communication already started, and the field of sensing and imaging was revolutionized, too. Non-classical states of light promise a phase sensitivity beyond any classical possibility [PRL 112, 103604 (2014)] and super-resolution capability [Nature Commun. 8, 14786 (2017)]. Moreover, based on quantum correlations, which are rooted in the very heart of quantum mechanics, the imaging of samples with photons that have never interacted with the object is feasible. This science fiction like phenomenon was first investigated by Mandel [PRA 44, 4614 (1991)] and later implemented for actual imaging purposes in the Zeilinger group [Nature 512, 409 (2014)]. We are going to present the transfer of this approach into applicable quantum technology within the realm of the Fraunhofer Key Research Initiative Quantum Methods for Advanced Imaging Solutions (QUILT). The method itself is based on induced coherence without induced emission [PRA 44, 4614 (1991)]. We built a novel compact implementation of this scheme based on only one nonlinear crystal. The crystal is coherently pumped by a laser from two sides such that signal and idler photon pairs can be collinearly emitted in either of two opposite directions (to the right or to the left). On the right side the idler beam will be separated by a dichroic mirror (DM) and interacts with an object (directly placed in front of a mirror or reflective object). On the left side the signal beam will be separated by another dichroic mirror and hit the camera, which is either a sCMOS or an EMCCD. Additional lenses provide the particular imaging. Sine the two possibilities for the idler beam – going right and interact with the object or going left from the nonlinear crystal – interfere the object could be observed by idler detection. However, the same interference can be observed for the signal beams although the never interacted with the object. Hence, the object can be imaged by detecting the signal light only. The crucial point here is the lack of wich-path information of the idler beams in this type of Michelson interferometric setup. The following points should be emphasized: (i) the signal channels never interact with the object, (ii) there is no induced emission due to the idler beam that interacted with the object, and (iii) there is no coincidence detection involved in this scheme. The obvious advantage of this technique is that the wavelength of the idler photons can be tailored to match the interesting spectral range for interaction with the object. At the same time, the signal photons, which are actually detected, can stay in the VIS range where, e.g., Si-based detectors are optimized. Besides the application for life science imaging, we are comparing the quantum imaging properties utilizing momentum correlations or spatial correlations, where the ladder is a modus that was never investigated before. As an outlook we work on significantly enhance SPDC sources in scope of quantum performance and wavelength separation. Obviously, pushing the short-wavelength idler photons further into the deep UV or XUV broadens the range of applications, but must be implemented by non-SPDC photon pair sources.

Quantum Communications and Quantum Imaging•Sep 10, 2019•0 citations
Imaging via nonlinear interferometers make use of induced coherence and take advantage of photon pair correlations to image an object without detecting the photons that illuminate the object [1]. The object's information is transferred from the photon that illuminates the object to the interference pattern of its partner photon, which is detected [2]. Spontaneous parametric down conversion allows to utilize photon pairs with large spectral separation. This fact becomes relevant if we need to image at wavelengths with detection constraints, e.g., mid-infrared, hyperspectral, or terahertz wavelengths [3], [4].
Imaging based on the induced coherence effect makes use of photon pairs to obtain information of an object without detecting the light that probes it. While one photon illuminates the object, only its partner is detected, so no measurement of coincidence events is needed. The sought-after object's information is revealed, observing a certain interference pattern on the detected photon. Here, we demonstrate experimentally that this imaging technique can be made resilient to noise. We introduce an imaging distillation approach based on the interferometric modulation of the signal of interest. We show that our scheme can generate a high-quality image of an object even against noise levels up to 250 times the actual signal of interest. We also include a detailed theoretical explanation of our findings.
We present principles of quantum imaging with undetected photons (QIUP) and show modifications we made to the nonlinear interferometer for QUIP in order to use off-axes holography for faster image reconstruction. We present images made by off-axes quantum holography (OAQH) and discuss image capabilities of the system. In this work we use a pair of quantum correlated photons, generated by spontaneous parametric down-conversion in a non-linear crystal; one photon form a pair interacts with object, and another is detected. In our system both photons are in near infra-red, but by slight modifications they will be in different spectral regions, interacting photons in mid infra-red, detected photons in visible or near infra-ed. This opens very useful applications of QIUP for imaging and sensing in MIR.
Quantum imaging with undetected photons allows for imaging an object by detecting photons that never interacted with it, using the correlation between photon pairs generated in the process of spontaneous parametric down conversion (SPDC) [1] . Through SPDC in a χ (2) material, a pump (P) photon of wavelength λ P can split into a pair of signal (S) and idler (I) photons, such that 1/ λ P = 1/ λ S + 1/ λ I . In such imaging schemes, the object’s optical properties at λ I , such as its absorption profile, can be inferred by only imaging the signal photons. Thus, one can image in challenging spectral ranges, such as mid-IR for λ I , using detectors in the visible for λ S [1] . In this scheme, the resolution is fundamentally diffraction-limited to the wavelength that interacts with the object, λ I [2] . We show that one can go beyond this diffraction limit by placing the object in the near-field of a subwavelength thin SPDC source, as shown schematically in Fig. 1(a) , through transferring the near-field information at λ I into propagating modes at λ S that can be detected in the far field. In this scheme, the resolution of imaging the object at λ I is determined by the detected signal wavelength λ S . As an application, we numerically demonstrate how two closely-spaced small scatterers at mid-IR can be resolved with a visible-range resolution.
Quantum sensing in the infrared regime often demands the use of expensive and cryogenically operated detectors. Nonlinear interferometry has paved the way for information transfer from the infrared to the near--infrared or visible regime in various quantum technologies. A particularly interesting application of these interferometers involves spectrally--resolved quantum imaging using undetected photons, enabled by the use of temperature--tunable parametric amplifiers. In this work, we demonstrate spectrally resolved transmission imaging with undetected photons around 1550 nm using a spontaneous parametric down conversion based folded nonlinear interferometric scheme, registering the attenuation of a zebrafish larva as a biological feasibility test. We characterize and calibrate the interferometer, having achieved spectrally resolved interference fringes with a maximum baseline visibility of ∼74%\sim 74\%∼74% in the near--infrared regime. Phase--stepped readout of a grating spectrometer gives a resolving power of ∼1460\sim1460∼1460 (from the spectrometer's point spread function) at 1550 nm, and ∼730\sim 730∼730 from the coherence length, the finest reported for imaging with undetected photons, over an instantaneous spectral window of ≈51\approx 51≈51 cm−1^{-1}−1.
Quantum imaging with undetected light (QIUL) leverages the quantum correlations of photon pairs generated via spontaneous parametric down-conversion (SPDC) to retrieve both amplitude and phase information of an object. This method enables illumination and detection at distinct wavelength ranges, utilizing advanced detection technology in the visible spectrum while probing the object at an exotic wavelength. Here, we experimentally demonstrate a QIUL technique incorporating Fourier off-axis holography within a hybrid-type induced-coherence nonlinear interferometer. Our approach reconstructs the amplitude and phase information of an object in a single shot using a wide-field configuration, presenting a viable alternative to multi-frame acquisition techniques such as phase-shifting holography.
Since the second quantum revolution, the growing exploitation of quantum states led to many sophisticated and novel applications [Phil. Trans. R. Soc. Lond. A 361, 1655 (2003). Former, mainly academic research is more and more transferred into real-world quantum technology ready to serve practical tasks. Today, the quantum computer is within reach, satellite based quantum communication already started, and the field of sensing and imaging was revolutionized, too. Non-classical states of light promise a phase sensitivity beyond any classical possibility [PRL 112, 103604 (2014)] and super-resolution capability [Nature Commun. 8, 14786 (2017)]. Moreover, based on quantum correlations, which are rooted in the very heart of quantum mechanics, the imaging of samples with photons that have never interacted with the object is feasible. This science fiction like phenomenon was first investigated by Mandel [PRA 44, 4614 (1991)] and later implemented for actual imaging purposes in the Zeilinger group [Nature 512, 409 (2014)]. We are going to present the transfer of this approach into applicable quantum technology within the realm of the Fraunhofer Key Research Initiative Quantum Methods for Advanced Imaging Solutions (QUILT). The method itself is based on induced coherence without induced emission [PRA 44, 4614 (1991)]. We built a novel compact implementation of this scheme based on only one nonlinear crystal. The crystal is coherently pumped by a laser from two sides such that signal and idler photon pairs can be collinearly emitted in either of two opposite directions (to the right or to the left). On the right side the idler beam will be separated by a dichroic mirror (DM) and interacts with an object (directly placed in front of a mirror or reflective object). On the left side the signal beam will be separated by another dichroic mirror and hit the camera, which is either a sCMOS or an EMCCD. Additional lenses provide the particular imaging. Sine the two possibilities for the idler beam – going right and interact with the object or going left from the nonlinear crystal – interfere the object could be observed by idler detection. However, the same interference can be observed for the signal beams although the never interacted with the object. Hence, the object can be imaged by detecting the signal light only. The crucial point here is the lack of wich-path information of the idler beams in this type of Michelson interferometric setup. The following points should be emphasized: (i) the signal channels never interact with the object, (ii) there is no induced emission due to the idler beam that interacted with the object, and (iii) there is no coincidence detection involved in this scheme. The obvious advantage of this technique is that the wavelength of the idler photons can be tailored to match the interesting spectral range for interaction with the object. At the same time, the signal photons, which are actually detected, can stay in the VIS range where, e.g., Si-based detectors are optimized. Besides the application for life science imaging, we are comparing the quantum imaging properties utilizing momentum correlations or spatial correlations, where the ladder is a modus that was never investigated before. As an outlook we work on significantly enhance SPDC sources in scope of quantum performance and wavelength separation. Obviously, pushing the short-wavelength idler photons further into the deep UV or XUV broadens the range of applications, but must be implemented by non-SPDC photon pair sources.