Research and Review Journal of Nondestructive Testing

Optimization of Computed Tomography Data Acquisition by Means of Quantum Computing

Theobald O. J. Fuchs, Melanie Basting, Kilian Dremel, Markus Firsching, Stefan Kasperl, Thomas Lang, Dimitri Prjamkov, Richard Schielein, Simon Semmler, Daniel Suth, Mareike Weule

Published Aug 1, 2023• 3 citations
Publisher

Abstract

Quantum Computing (QC) technology has made tremendous progress recently. Today, first real QC systems are operational. The Fraunhofer Institute of Integrated Circuits IIS, Division Development Center X-ray Technology is participating in the project BayQS, which aims at identifying and evaluating potential applications of quantum computing in the field of non-destructive testing by means of X-ray imaging. Computed tomography (CT) is a well-established method of 3-D imaging in medicine and industry since several decades. The quality of the resulting volumetric datasets depends essentially on a set of around 20 physical parameters controlling the set-up of X-ray source, X-ray digital detector array, movable mechanical components, sample rotation, and image processing. Hence, we started investigating the potential use of a quantum-based optimization method to optimize CT data acquisition. As a first approach, we focused on the task to minimize the number of projection images required to achieve unaltered image quality when compared to an acquisition over the full 4π solid angle. Minimizing involves a cost function. There are several ways to define this cost function. In order to transfer the task to a QC system, the problem is reformulated as a Quadratic Unconstrained Binary Optimization (QUBO). A decisive feature of the QUBO is, that is can be solved by a hybrid implementation on quantum devices, which combines a classical part to iteratively find the maximum of the cost function and a quantum circuit to evaluate the respective cost function for each combination of projections. This procedure is called quantum approximate optimization algorithm (QAOA). The experiments were performed via the qiskit script language on an IBM Quantum System One located in Ehingen, Germany. This QC system offers 27 qubits and enables first real world experiments with small test datasets.

DOI
10.58286/28209

Related papers

Quantum optimization algorithms for CT image segmentation from X-ray data

Kyungtaek Jun, Hyunju Lee

Computed tomography (CT) is an important imaging technique used in medical analysis of the internal structure of the human body. Previously, image segmentation methods were required after acquiring reconstructed CT images to obtain segmented CT images which made it susceptible to errors from both reconstruction and segmentation algorithms. However, this paper introduces a new approach using an advanced quantum optimization algorithm called quadratic unconstrained binary optimization (QUBO) for CT image segmentation. This algorithm allows CT image reconstruction and segmentation to be performed simultaneously. This algorithm segments CT images by minimizing the difference between a sinogram in a superposition state with qubits, obtained using the mathematical projection including the Radon transform, and the experimentally acquired sinogram from X-ray images for various angles. Furthermore, we leveraged X-ray mass attenuation coefficients to reduce the number of logical qubits required for our quantum optimization algorithm, and we employed D-Wave's hybrid solver to solve the optimization problem. We compared the segmentation results of our algorithm with those of classical algorithms using X-ray images of actual tooth samples to validate the results of our algorithm. The comparison revealed that, after undergoing appropriate image post-processing, our algorithm's segmentation results matched those of classical algorithms that perform segmentation after reconstruction, except for some pixels at the boundary. We expect that the new quantum optimization CT algorithm will bring about great advancements in medical imaging.

arXiv:2306.05522•Scientific Reports•Jul 1, 2025•29 citations

Utilizing Quantum Annealing in Computed Tomography Image Reconstruction

Kilian Dremel, Dimitri Prjamkov, Markus Firsching +6 more

One of the primary difficulties in computed tomography (CT) is reconstructing cross-sectional images from measured projections of a physical object. There exist several classical methods for this task of generating a digital representation of the object, including filtered backprojection or simultaneous algebraic reconstruction technique. Our research aims to explore the potential of quantum computing in the field of industrial X-ray transmission tomography. Specifically, this work focuses on the application of a method similar to that proposed by Nau et al. (2023) on real CT data to demonstrate the feasibility of quadratic-unconstrained-binary-optimization-based tomographic reconstruction. Starting with simulated phantoms, results with simulated annealing as well as real annealing hardware are shown, leading to the application on measured cone-beam CT data. The results demonstrate that tomographic reconstruction using quantum annealing is feasible for both simulated and real-world applications. Yet, current limitations—involving the maximum processable size and bit depth of voxel values of the images, both correlated with the number of densely connected qubits within the annealing hardware—imply the need of future research to further improve the results. This approach, despite its early stage, has the potential to enable more sophisticated reconstructions, providing an alternative to traditional classical methods.

IEEE Transactions on Quantum Engineering•Jan 1, 2025•16 citations

Quantum Computing as a Future Tool for 3-D X-ray Imaging and Image Processing: Latest Progress and Perspectives

Theobald O. J. Fuchs, Thomas Lang, Markus Firsching +6 more

This contribution will sum-up the current state of Quantum Computing and give a short overview of the theoretical background. The concept of qubits, superposition, entanglement and measurement of quantum states will be explained. In particular the interaction of multiple quantum objects lead to highly complex combined states, represented by high-dimensional matrices. Quantum gates and circuits built from these gates will be introduced. Next, we will report on the current state of our research on several applications of QC. These include an implementation of cross-sectional image reconstruction for CT imaging based on a QUBO-method (Quadratic Unconstrained Binary Optimization), used to find a mathematical minimum of a metric. Another topic, we are working on, is optimization of X-ray source trajectory in CT with respect to image quality achievable by a restricted number of angular positions. In addition, we evaluate various encoding techniques for images. Based on that we examine common problems of image processing for instance noise reduction and search for ways to implement respective methods on the QC.

e-Journal of Nondestructive Testing•Jul 1, 2026•0 citations

Quantum Compressed Sensing Tomographic Reconstruction Algorithm

Arim Ryou, Kiwoong Kim, Kyungtaek Jun

Computed tomography (CT) is a non-destructive technique for observing internal images and has proven highly valuable in medical diagnostics. Recent advances in quantum computing have begun to influence tomographic reconstruction techniques. The quantum tomographic reconstruction algorithm is less affected by artifacts or noise than classical algorithms by using the square function of the difference between pixels obtained by projecting CT images in quantum superposition states and pixels obtained from experimental data. In particular, by using quantum linear systems, a fast quadratic unconstrained binary optimization (QUBO) model formulation for quantum tomographic reconstruction is possible. In this paper, we formulate the QUBO model for quantum compressed sensing tomographic reconstruction, which is a linear combination of the QUBO model for quantum tomographic reconstruction and the QUBO model for total variation in quantum superposition-state CT images. In our experiments, we used sinograms obtained by using the Radon transform of Shepp-Logan images and body CT images. We evaluate the performance of the new algorithm by reconstructing CT images using a hybrid solver with the QUBO model computed from each sinogram. The new algorithm was able to obtain a solution within 5 projection images for 30 × 30 image samples and within 6 projection images for 60 × 60 image samples, reconstructing error-free CT images. We anticipate that quantum compressed sensing tomographic reconstruction algorithms could significantly reduce the total radiation dose when quantum computing performance advances.

arXiv:2505.11286•IEEE Transactions on Quantum Engineering•Jan 1, 2026•7 citations

Towards Optimization of Emission Tomography System Design using Quantum and Classical Computations

Merlin Arthur Nau

This thesis investigates inverse problems in emission tomography from three complementary perspectives: the application of quantum computing to emission tomography reconstruction, the system-level analysis of Single Photon Emission Computed Tomography (SPECT) imaging operators through null space characterization, and the use of Quantum Annealing (QA) for feature selection in medical imaging. Emission tomography enables the visualization of biological processes by detecting radiation emitted from a radiopharmaceutical administered to a patient. Reconstructing the spatial distribution of radiotracer activity from the acquired projection data constitutes a high-dimensional, ill-posed inverse problem that is further complicated by photon noise, attenuation, and incomplete angular sampling. Traditional iterative reconstruction methods, while effective, face challenges related to convergence, noise amplification, and sensitivity to system modeling assumptions. The first contribution of this thesis explores the feasibility of QA for emission tomography image reconstruction. The least-squares reconstruction problem is formulated as a Quadratic Unconstrained Binary Optimization (QUBO) model and solved using a hybrid quantum-classical solver. The method is evaluated on synthetic binary and integer-valued images of varying size, bit depth, and noise. Experiments on the D-Wave quantum annealer demonstrate that binary reconstructions are feasible for small image sizes directly on the quantum processing unit, while a hybrid solver extends the tractable image size to 32 × 32 pixels. However, scaling to higher bit depths introduces heterogeneous high-frequency noise and reveals classical bottlenecks in QUBO construction. To address the artifacts observed at increased bit depth, the second contribution introduces regularization techniques compatible with the QA formulation. Specifically, L2 and Total Variation (TV) regularization terms are incorporated into the optimization objective. These regularization strategies enforce smoothness and edge preservation in the reconstructed images and are shown to substantially improve reconstruction fidelity under the constrained discrete optimization framework, although the results remain below the quality achievable by conventional filtered backprojection. The third contribution shifts the focus from quantum-based reconstruction to a system-level analysis of SPECT imaging operators. The null space of the projection operator, which comprises all image components that are invisible to the measurement process, is computed for realistic three-dimensional (3-D) SPECT systems using an iterative Landweber-type algorithm. The analysis encompasses both conventional parallel-hole and multi-focal collimator geometries, including SMARTZOOM™ configurations used in cardiac and neurological imaging. The influence of acquisition parameters such as the number of projection views, angular sampling density, and depth-dependent point spread function modeling is systematically evaluated. Experiments on quality-control and anthropomorphic phantoms reveal that the null space is minimized by increasing angular coverage and finer sampling, and that point spread function modeling introduces characteristic ring-like structures in the null space corresponding to known reconstruction artifacts. The fourth contribution extends the use of QA to a related inverse problem: feature selection for image reconstruction. Rather than reconstructing the image directly, the objective is to identify a subset of the most informative pixels from medical images using a mutual information-based QUBO formulation. To make the problem compatible with current quantum hardware, the QUBO is spatially subsampled and sparsified to respect the limited qubit connectivity of the D-Wave Pegasus topology, and a soft linear constraint enforces the selection of a fixed number of features. The selected pixels serve as a compressed representation that is used to train a convolutional decoder for image reconstruction. Experiments on the MedMNIST benchmark demonstrate that the QA-based feature selection achieves performance comparable to classical QUBO simulations and outperforms several conventional pixel-level feature selection methods, while deep learning-based feature extractors yield higher reconstruction quality at the expense of interpretability. Overall, this thesis contributes to the understanding of how emerging quantum technologies can be applied to medical image reconstruction and related inverse problems, and provides a framework for evaluating the fundamental limitations of emission tomography systems through null space analysis.

•Jan 1, 2026•0 citations

Quantum annealing-based computed tomography using variational approach for a real-number image reconstruction

Akihiro Haga

Objective . Despite recent advancements in quantum computing, the limited number of available qubits has hindered progress in CT reconstruction. This study investigates the feasibility of utilizing quantum annealing-based computed tomography (QACT) with current quantum bit levels. Approach . The QACT algorithm aims to precisely solve quadratic unconstrained binary optimization problems. Furthermore, a novel approach is proposed to reconstruct images by approximating real numbers using the variational method. This approach allows for accurate CT image reconstruction using a small number of qubits. The study examines the impact of projection data quantity and noise on various image sizes ranging from 4 × 4 to 24 × 24 pixels. The reconstructed results are compared against conventional reconstruction algorithms, namely maximum likelihood expectation maximization (MLEM) and filtered back projection (FBP). Main result . By employing the variational approach and utilizing two qubits for each pixel of the image, accurate reconstruction was achieved with an adequate number of projections. Under conditions of abundant projections and lower noise levels, the image quality in QACT algorithm outperformed that of MLEM and FBP algorithms. However, in situations with limited projection data and in the presence of noise, the image quality in QACT was inferior to that in MLEM. Significance . This study developed the QACT reconstruction algorithm using the variational approach for real-number reconstruction. Remarkably, only 2 qubits were required for each pixel representation, demonstrating their sufficiency for accurate reconstruction.

arXiv:2306.02214•Physics in Medicine and Biology•Feb 8, 2024•12 citations
Quantum Computing (QC) technology has made tremendous progress recently. Today, first real QC systems are operational. The Fraunhofer Institute of Integrated Circuits IIS, Division Development Center X-ray Technology is participating in the project BayQS, which aims at identifying and evaluating potential applications of quantum computing in the field of non-destructive testing by means of X-ray imaging. Computed tomography (CT) is a well-established method of 3-D imaging in medicine and industry since several decades. The quality of the resulting volumetric datasets depends essentially on a set of around 20 physical parameters controlling the set-up of X-ray source, X-ray digital detector array, movable mechanical components, sample rotation, and image processing. Hence, we started investigating the potential use of a quantum-based optimization method to optimize CT data acquisition. As a first approach, we focused on the task to minimize the number of projection images required to achieve unaltered image quality when compared to an acquisition over the full 4π solid angle. Minimizing involves a cost function. There are several ways to define this cost function. In order to transfer the task to a QC system, the problem is reformulated as a Quadratic Unconstrained Binary Optimization (QUBO). A decisive feature of the QUBO is, that is can be solved by a hybrid implementation on quantum devices, which combines a classical part to iteratively find the maximum of the cost function and a quantum circuit to evaluate the respective cost function for each combination of projections. This procedure is called quantum approximate optimization algorithm (QAOA). The experiments were performed via the qiskit script language on an IBM Quantum System One located in Ehingen, Germany. This QC system offers 27 qubits and enables first real world experiments with small test datasets.
Computed tomography (CT) is an important imaging technique used in medical analysis of the internal structure of the human body. Previously, image segmentation methods were required after acquiring reconstructed CT images to obtain segmented CT images which made it susceptible to errors from both reconstruction and segmentation algorithms. However, this paper introduces a new approach using an advanced quantum optimization algorithm called quadratic unconstrained binary optimization (QUBO) for CT image segmentation. This algorithm allows CT image reconstruction and segmentation to be performed simultaneously. This algorithm segments CT images by minimizing the difference between a sinogram in a superposition state with qubits, obtained using the mathematical projection including the Radon transform, and the experimentally acquired sinogram from X-ray images for various angles. Furthermore, we leveraged X-ray mass attenuation coefficients to reduce the number of logical qubits required for our quantum optimization algorithm, and we employed D-Wave's hybrid solver to solve the optimization problem. We compared the segmentation results of our algorithm with those of classical algorithms using X-ray images of actual tooth samples to validate the results of our algorithm. The comparison revealed that, after undergoing appropriate image post-processing, our algorithm's segmentation results matched those of classical algorithms that perform segmentation after reconstruction, except for some pixels at the boundary. We expect that the new quantum optimization CT algorithm will bring about great advancements in medical imaging.
One of the primary difficulties in computed tomography (CT) is reconstructing cross-sectional images from measured projections of a physical object. There exist several classical methods for this task of generating a digital representation of the object, including filtered backprojection or simultaneous algebraic reconstruction technique. Our research aims to explore the potential of quantum computing in the field of industrial X-ray transmission tomography. Specifically, this work focuses on the application of a method similar to that proposed by Nau et al. (2023) on real CT data to demonstrate the feasibility of quadratic-unconstrained-binary-optimization-based tomographic reconstruction. Starting with simulated phantoms, results with simulated annealing as well as real annealing hardware are shown, leading to the application on measured cone-beam CT data. The results demonstrate that tomographic reconstruction using quantum annealing is feasible for both simulated and real-world applications. Yet, current limitations—involving the maximum processable size and bit depth of voxel values of the images, both correlated with the number of densely connected qubits within the annealing hardware—imply the need of future research to further improve the results. This approach, despite its early stage, has the potential to enable more sophisticated reconstructions, providing an alternative to traditional classical methods.
This contribution will sum-up the current state of Quantum Computing and give a short overview of the theoretical background. The concept of qubits, superposition, entanglement and measurement of quantum states will be explained. In particular the interaction of multiple quantum objects lead to highly complex combined states, represented by high-dimensional matrices. Quantum gates and circuits built from these gates will be introduced. Next, we will report on the current state of our research on several applications of QC. These include an implementation of cross-sectional image reconstruction for CT imaging based on a QUBO-method (Quadratic Unconstrained Binary Optimization), used to find a mathematical minimum of a metric. Another topic, we are working on, is optimization of X-ray source trajectory in CT with respect to image quality achievable by a restricted number of angular positions. In addition, we evaluate various encoding techniques for images. Based on that we examine common problems of image processing for instance noise reduction and search for ways to implement respective methods on the QC.
Computed tomography (CT) is a non-destructive technique for observing internal images and has proven highly valuable in medical diagnostics. Recent advances in quantum computing have begun to influence tomographic reconstruction techniques. The quantum tomographic reconstruction algorithm is less affected by artifacts or noise than classical algorithms by using the square function of the difference between pixels obtained by projecting CT images in quantum superposition states and pixels obtained from experimental data. In particular, by using quantum linear systems, a fast quadratic unconstrained binary optimization (QUBO) model formulation for quantum tomographic reconstruction is possible. In this paper, we formulate the QUBO model for quantum compressed sensing tomographic reconstruction, which is a linear combination of the QUBO model for quantum tomographic reconstruction and the QUBO model for total variation in quantum superposition-state CT images. In our experiments, we used sinograms obtained by using the Radon transform of Shepp-Logan images and body CT images. We evaluate the performance of the new algorithm by reconstructing CT images using a hybrid solver with the QUBO model computed from each sinogram. The new algorithm was able to obtain a solution within 5 projection images for 30 × 30 image samples and within 6 projection images for 60 × 60 image samples, reconstructing error-free CT images. We anticipate that quantum compressed sensing tomographic reconstruction algorithms could significantly reduce the total radiation dose when quantum computing performance advances.
This thesis investigates inverse problems in emission tomography from three complementary perspectives: the application of quantum computing to emission tomography reconstruction, the system-level analysis of Single Photon Emission Computed Tomography (SPECT) imaging operators through null space characterization, and the use of Quantum Annealing (QA) for feature selection in medical imaging. Emission tomography enables the visualization of biological processes by detecting radiation emitted from a radiopharmaceutical administered to a patient. Reconstructing the spatial distribution of radiotracer activity from the acquired projection data constitutes a high-dimensional, ill-posed inverse problem that is further complicated by photon noise, attenuation, and incomplete angular sampling. Traditional iterative reconstruction methods, while effective, face challenges related to convergence, noise amplification, and sensitivity to system modeling assumptions. The first contribution of this thesis explores the feasibility of QA for emission tomography image reconstruction. The least-squares reconstruction problem is formulated as a Quadratic Unconstrained Binary Optimization (QUBO) model and solved using a hybrid quantum-classical solver. The method is evaluated on synthetic binary and integer-valued images of varying size, bit depth, and noise. Experiments on the D-Wave quantum annealer demonstrate that binary reconstructions are feasible for small image sizes directly on the quantum processing unit, while a hybrid solver extends the tractable image size to 32 × 32 pixels. However, scaling to higher bit depths introduces heterogeneous high-frequency noise and reveals classical bottlenecks in QUBO construction. To address the artifacts observed at increased bit depth, the second contribution introduces regularization techniques compatible with the QA formulation. Specifically, L2 and Total Variation (TV) regularization terms are incorporated into the optimization objective. These regularization strategies enforce smoothness and edge preservation in the reconstructed images and are shown to substantially improve reconstruction fidelity under the constrained discrete optimization framework, although the results remain below the quality achievable by conventional filtered backprojection. The third contribution shifts the focus from quantum-based reconstruction to a system-level analysis of SPECT imaging operators. The null space of the projection operator, which comprises all image components that are invisible to the measurement process, is computed for realistic three-dimensional (3-D) SPECT systems using an iterative Landweber-type algorithm. The analysis encompasses both conventional parallel-hole and multi-focal collimator geometries, including SMARTZOOM™ configurations used in cardiac and neurological imaging. The influence of acquisition parameters such as the number of projection views, angular sampling density, and depth-dependent point spread function modeling is systematically evaluated. Experiments on quality-control and anthropomorphic phantoms reveal that the null space is minimized by increasing angular coverage and finer sampling, and that point spread function modeling introduces characteristic ring-like structures in the null space corresponding to known reconstruction artifacts. The fourth contribution extends the use of QA to a related inverse problem: feature selection for image reconstruction. Rather than reconstructing the image directly, the objective is to identify a subset of the most informative pixels from medical images using a mutual information-based QUBO formulation. To make the problem compatible with current quantum hardware, the QUBO is spatially subsampled and sparsified to respect the limited qubit connectivity of the D-Wave Pegasus topology, and a soft linear constraint enforces the selection of a fixed number of features. The selected pixels serve as a compressed representation that is used to train a convolutional decoder for image reconstruction. Experiments on the MedMNIST benchmark demonstrate that the QA-based feature selection achieves performance comparable to classical QUBO simulations and outperforms several conventional pixel-level feature selection methods, while deep learning-based feature extractors yield higher reconstruction quality at the expense of interpretability. Overall, this thesis contributes to the understanding of how emerging quantum technologies can be applied to medical image reconstruction and related inverse problems, and provides a framework for evaluating the fundamental limitations of emission tomography systems through null space analysis.
Objective . Despite recent advancements in quantum computing, the limited number of available qubits has hindered progress in CT reconstruction. This study investigates the feasibility of utilizing quantum annealing-based computed tomography (QACT) with current quantum bit levels. Approach . The QACT algorithm aims to precisely solve quadratic unconstrained binary optimization problems. Furthermore, a novel approach is proposed to reconstruct images by approximating real numbers using the variational method. This approach allows for accurate CT image reconstruction using a small number of qubits. The study examines the impact of projection data quantity and noise on various image sizes ranging from 4 × 4 to 24 × 24 pixels. The reconstructed results are compared against conventional reconstruction algorithms, namely maximum likelihood expectation maximization (MLEM) and filtered back projection (FBP). Main result . By employing the variational approach and utilizing two qubits for each pixel of the image, accurate reconstruction was achieved with an adequate number of projections. Under conditions of abundant projections and lower noise levels, the image quality in QACT algorithm outperformed that of MLEM and FBP algorithms. However, in situations with limited projection data and in the presence of noise, the image quality in QACT was inferior to that in MLEM. Significance . This study developed the QACT reconstruction algorithm using the variational approach for real-number reconstruction. Remarkably, only 2 qubits were required for each pixel representation, demonstrating their sufficiency for accurate reconstruction.