International Conference on Space Optics (ICSO)

Micro-integrated optical systems and qualification of adhesive integration technologies for cold atomic quantum sensors

Marc Christ, Anne Stiekel, Christoph Stölmacker, C. Zimmermann, Alexander Kassner, Marc Christopher Wurz, Markus Krutzik

Published Jul 12, 2023• 2 citations
Publisher

Abstract

Cold atom based quantum sensors require robust and miniaturized optical systems for applications on mobile platforms. A micro-integrated optical system (volume ∼25 mL) for trapping and manipulation of neutral atoms is presented. This setup focuses and precisely overlaps two high power laser beams (1064 nm, up to 2W total, wR = 34 µm) launched via a single-mode, polarization maintaining optical fiber, thereby realizing a crossed beam optical dipole trap (ODT). Adhesive bonding is qualified in application relevant geometries and material systems of micro-integrated optical systems for application on mobile platforms or space. Fused silica test blocks (bond area 2 × 4 mm2 ) are bonded with four different adhesives on silicon wafers. Theses samples are aged by thermal cycling (up to −55 °C to 150 °C) and/or gamma-radiation (10 000 mSv) and subsequently the bond strength is evaluated by die shear testing according to MIL-STD-883L. The influence of the environmental aging on the bond strength is presented, the failure mode and the influence of fillets discussed. In addition, the effects of plasma cleaning on the bond strength in this geometry is presented.

DOI
10.1117/12.2689275

Related papers

Integrated atomic quantum technologies in demanding environments: Development and qualification of miniaturized optical setups and integration technologies for UHV and space operation

Marc Christ, Alexander Kassner, Robert Smol +6 more

Employing compact quantum sensors in field or in space (e.g., small satellites) implies demanding requirements on components and integration technologies. Within our work on integrated sensors, we develop miniaturized, ultra-stable optical setups for optical cooling and trapping of cold atomic gases. Besides challenging demands on alignment precision, and thermo-mechanical durability, we specifically address ultra-high vacuum (UHV) compatibility of our integration technologies and optical components. A prototype design of an UHV-compatible, crossed beam optical dipole trap setup and its application within a cold atomic quantum sensor is described. First qualification efforts on adhesive micro-integration technologies are presented. These tests are conducted in application-relevant geometries and material combinations common for micro-integrated optical setups. Adhesive aging will be investigated by thermal cycling or gamma radiation exposure. For vacuum compatibility testing, a versatile UHV testing system is currently being set up, enabling residual gas analysis and measurement of total gas rates down to 5•10-10mbar l/s at a base pressure of 10-11 mbar, exceeding the common ASTM E595 test.

•Jan 1, 2018•0 citations

Integrated atomic quantum technologies in demanding environments: development and qualification of miniaturized optical setups and integration technologies for UHV and space operation

Marc Christ, Alexander Kassner, Robert Smol +6 more

Employing compact quantum sensors in field or in space (e.g., small satellites) implies demanding requirements on components and integration technologies. Within our work on integrated sensors, we develop miniaturized, ultra-stable optical setups for optical cooling and trapping of cold atomic gases. Besides challenging demands on alignment precision, and thermo-mechanical durability, we specifically address ultra-high vacuum (UHV) compatibility of our integration technologies and optical components. A prototype design of an UHV-compatible, crossed beam optical dipole trap setup and its application within a cold atomic quantum sensor is described. First qualification efforts on adhesive micro-integration technologies are presented. These tests are conducted in application-relevant geometries and material combinations common for micro-integrated optical setups. Adhesive aging will be investigated by thermal cycling or gamma radiation exposure. For vacuum compatibility testing, a versatile UHV testing system is currently being set up, enabling residual gas analysis and measurement of total gas rates down to 5•10-10mbar l/s at a base pressure of 10-11 mbar, exceeding the common ASTM E595 test.

International Conference on Space Optics (ICSO)•Jul 12, 2019•1 citation

Micro-integrated crossed-beam optical dipole trap system with long-term alignment stability for mobile atomic quantum technologies

Marc Christ, Oliver Anton, Conrad Zimmermann +3 more

Quantum technologies extensively use laser light for state preparation, manipulation, and readout. For field applications, these systems must be robust and compact, driving the need for miniaturized and highly stable optical setups and system integration. In this work, we present a micro-integrated crossed-beam optical dipole trap setup, the µXODT, designed for trapping and cooling 87 Rb. This fiber-coupled setup operates at 1064 nm wavelength with up to 2.5 W optical power and realizes a free-space crossed beam geometry. The µXODT precisely overlaps two focused beams ( w 0 ≈ 33 µm) at their waists in a 45° crossing angle, achieving a position difference of ≤3.4 µm and a 0.998 power ratio between both beams with long-term stability. We describe the design and assembly process in detail, along with optical and thermal tests with temperatures of up to 65 °C. The system’s volume of 25 ml represents a reduction of more than two orders of magnitude compared to typically used macroscopic setups while demonstrating exceptional mechanical robustness and thermal stability. The µXODT is integrated with an 87 Rb 3D MOT setup, trapping 3 × 10 5 atoms from a laser-cooled atomic cloud, and has shown no signs of degradation after two years of operation.

arXiv:2408.07187•Optics Express•Sep 25, 2024•3 citations

Miniaturized Optical Frequency Reference and Crossed Beam Optical Dipole Trap Systems for Compact Atom-Based Quantum Sensors

Marc Christ, Conrad Zimmermann, Sascha Neinert +4 more

Atomic quantum technologies enable advanced timekeeping and sensing by leveraging their high precision and accuracy. We focus on developing integrated and robust atom-based quantum sensors through the miniaturization of physics packages, which require highly stable optical frequencies and tools to control and manipulate atoms. Their application in the field demands ultra-stable micro-integrated optical systems, scalable integration techniques, and cost-effective, reproducible production methods.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations

Miniaturized Crossed Beam Optical Dipole Trap for Compact Atom-Based Quantum Sensors

Marc Christ, Conrad Zimmermann, Oliver Anton +1 more

Cold atomic quantum sensors rely on the generation, manipulation, and detection of atomic quantum gases and are well proven within laboratory environments. For many applications in the areas of sensing, timekeeping and fundamental physics, these setups need to be realized as mobile and field compatible, miniaturized devices. However, this is still a major technological challenge.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations

Development and Qualification of UHV-Compatible, Micro-Integrated Optical Setups for Cold Atom Applications

Marc Christ, Achim Peters, Markus Krutzik

We present a tool for rapid prototyping and qualification of (electro-) optical components and adhesive integration techniques for micro-integrated assemblies operating in ultra-high vacuum environments.

Conference on Lasers and Electro-Optics•Jan 1, 2018•0 citations
Cold atom based quantum sensors require robust and miniaturized optical systems for applications on mobile platforms. A micro-integrated optical system (volume ∼25 mL) for trapping and manipulation of neutral atoms is presented. This setup focuses and precisely overlaps two high power laser beams (1064 nm, up to 2W total, wR = 34 µm) launched via a single-mode, polarization maintaining optical fiber, thereby realizing a crossed beam optical dipole trap (ODT). Adhesive bonding is qualified in application relevant geometries and material systems of micro-integrated optical systems for application on mobile platforms or space. Fused silica test blocks (bond area 2 × 4 mm2 ) are bonded with four different adhesives on silicon wafers. Theses samples are aged by thermal cycling (up to −55 °C to 150 °C) and/or gamma-radiation (10 000 mSv) and subsequently the bond strength is evaluated by die shear testing according to MIL-STD-883L. The influence of the environmental aging on the bond strength is presented, the failure mode and the influence of fillets discussed. In addition, the effects of plasma cleaning on the bond strength in this geometry is presented.
Employing compact quantum sensors in field or in space (e.g., small satellites) implies demanding requirements on components and integration technologies. Within our work on integrated sensors, we develop miniaturized, ultra-stable optical setups for optical cooling and trapping of cold atomic gases. Besides challenging demands on alignment precision, and thermo-mechanical durability, we specifically address ultra-high vacuum (UHV) compatibility of our integration technologies and optical components. A prototype design of an UHV-compatible, crossed beam optical dipole trap setup and its application within a cold atomic quantum sensor is described. First qualification efforts on adhesive micro-integration technologies are presented. These tests are conducted in application-relevant geometries and material combinations common for micro-integrated optical setups. Adhesive aging will be investigated by thermal cycling or gamma radiation exposure. For vacuum compatibility testing, a versatile UHV testing system is currently being set up, enabling residual gas analysis and measurement of total gas rates down to 5•10-10mbar l/s at a base pressure of 10-11 mbar, exceeding the common ASTM E595 test.
Employing compact quantum sensors in field or in space (e.g., small satellites) implies demanding requirements on components and integration technologies. Within our work on integrated sensors, we develop miniaturized, ultra-stable optical setups for optical cooling and trapping of cold atomic gases. Besides challenging demands on alignment precision, and thermo-mechanical durability, we specifically address ultra-high vacuum (UHV) compatibility of our integration technologies and optical components. A prototype design of an UHV-compatible, crossed beam optical dipole trap setup and its application within a cold atomic quantum sensor is described. First qualification efforts on adhesive micro-integration technologies are presented. These tests are conducted in application-relevant geometries and material combinations common for micro-integrated optical setups. Adhesive aging will be investigated by thermal cycling or gamma radiation exposure. For vacuum compatibility testing, a versatile UHV testing system is currently being set up, enabling residual gas analysis and measurement of total gas rates down to 5•10-10mbar l/s at a base pressure of 10-11 mbar, exceeding the common ASTM E595 test.
Quantum technologies extensively use laser light for state preparation, manipulation, and readout. For field applications, these systems must be robust and compact, driving the need for miniaturized and highly stable optical setups and system integration. In this work, we present a micro-integrated crossed-beam optical dipole trap setup, the µXODT, designed for trapping and cooling 87 Rb. This fiber-coupled setup operates at 1064 nm wavelength with up to 2.5 W optical power and realizes a free-space crossed beam geometry. The µXODT precisely overlaps two focused beams ( w 0 ≈ 33 µm) at their waists in a 45° crossing angle, achieving a position difference of ≤3.4 µm and a 0.998 power ratio between both beams with long-term stability. We describe the design and assembly process in detail, along with optical and thermal tests with temperatures of up to 65 °C. The system’s volume of 25 ml represents a reduction of more than two orders of magnitude compared to typically used macroscopic setups while demonstrating exceptional mechanical robustness and thermal stability. The µXODT is integrated with an 87 Rb 3D MOT setup, trapping 3 × 10 5 atoms from a laser-cooled atomic cloud, and has shown no signs of degradation after two years of operation.